verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GF300 · Air Filter (water separation + particulate filtration)

Airtac B52-GF Copper-Free Pneumatic Air Treatment Component B52-GF30015MJW

The AirTAC Airtac B52-GF Copper-Free Pneumatic Air Treatment Component B52-GF30015MJW is a genuine G-series air filter. It separates condensed water and filters particulate from the compressed-air line through a 5 µm element, with PT1/2" ports and a manual drain. A filter does not set downstream pressure — pair it with a GR regulator, or use a GFR filter regulator, when pressure control is needed.

  • TypeAir filter
  • Port sizePT1/2"
  • Filtering grade5 µm
  • DrainManual drain
  • Inlet pressure0 - 0.9 MPa (0 - 131 psi)
  • Bowl materialPC
  • ThreadPT
  • BracketSupplied without bracket
$26.39 $30.73Save 14% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac B52-GF Copper-Free Pneumatic Air Treatment Component B52-GF30015MJW

The AirTAC GF30015MJW is a G-series compressed-air filter that removes water and particulate only - no pressure regulation and no lubrication. It is size 300 with a 1/2 in PT (the standard thread) port, a polycarbonate manual-drain bowl, no mounting bracket (J), and the fine 5 um filter element (W) instead of the standard 40 um. Maximum inlet pressure for the manual-drain version is 0.9 MPa.

This is a genuine AirTAC part. The same body is available in the 40 um grade, with a bracket, and with automatic or differential-pressure drains across the 200-600 size range. AirTAC publishes flow as curves rather than a single rating, so we confirm the datasheet and flow figures for your application on request.

Airtac B52-GF Copper-Free Pneumatic Air Treatment Component B52-GF30015MJW Technical Specifications

ModelAirtac B52-GF Copper-Free Pneumatic Air Treatment Component B52-GF30015MJW
SeriesGF300 air filter
Port sizePT1/2" (PT thread)
Filtering grade5 µm
Drain typeManual drain
BracketSupplied without bracket
FluidCompressed air
Inlet pressure0 - 0.9 MPa (0 - 131 psi)
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Bowl materialPC
FeatureLow pressure loss

Specifications follow the official AirTAC G-series air-preparation data. The inlet-pressure band is set by the drain type: automatic and differential-pressure drains run 0.15 - 1.0 MPa, a manual drain runs 0 - 0.9 MPa. Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac B52-GF Copper-Free Pneumatic Air Treatment Component B52-GF30015MJW

GF300G-series air filter, 300 body — sets the port range.
15Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain. Options are differential (blank), automatic (A) or manual (M).
JSupplied without bracket. A bracket ships by default; J orders it without.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.

Field order is size, port, drain, bracket, grade, thread — a blank position takes the default. Example: GF300-10AJW is a 300 body, PT3/8", automatic drain, no bracket, 5 µm element, PT thread.

Size Class

  • GF200PT1/8" - PT1/4"
  • GF300PT1/4" - PT1/2"
  • GF400PT3/8" - PT1/2"
  • GF600PT3/4" - PT1"

A larger body carries a larger port and passes more air at the same pressure drop. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom rather than from a single rated figure. The GF600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGF300 · PT1/2" · 5 µm
One size downGF200
One size upGF400
Line orderFilter first, then regulator, then lubricator

Where the Airtac B52-GF Copper-Free Pneumatic Air Treatment Component B52-GF30015MJW Is Used

air

Pneumatic paint-spray booth supply

Installed in the airline feeding spray guns and air-assisted applicators, the 5 um element helps keep fine particulate out of the finishing air before a dedicated dryer or final point-of-use filter.

engineering

Robotics end-of-arm air feed

Mounted on the cabinet side of the supply to a robot cell's grippers and vacuum ejectors, it delivers cleaner air to the close-tolerance valves and small-bore tubing on the arm.

science

Analytical instrument purge air

Placed on the purge and actuation air line of laboratory analysers and environmental chambers, it removes water and fine particles that standard-grade filtration would leave behind.

Is the Airtac B52-GF Copper-Free Pneumatic Air Treatment Component B52-GF30015MJW the Right Filter?

Choose the W (5 um) element when the equipment downstream - precision valves, air bearings, coating equipment - needs finer filtration than the standard 40 um grade provides; remember the finer element loads faster and needs more attentive draining, so the manual bowl should sit where it can be reached. Size 300 at 1/2 in PT is the mid-range step; move to 400 or 600 if your flow curve demands it, or down to 200 for small feeds. No bracket is supplied with the J suffix; the bracketed MW version is the same filter otherwise.

Flow is published as curves, not a single rating - ask us to confirm the datasheet figure against your consumption before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain: differential, automatic or manual
  • ✓ Manual drain caps inlet at 0.9 MPa
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Bracket needed, or order with J
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, and follow the airflow arrow.
  • check Put the filter first in the air-preparation line.
  • check Keep inlet pressure within 0 - 0.9 MPa (0 - 131 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Replace the 5 µm element when pressure loss rises.

The PC bowl must not be cleaned with solvents or exposed to synthetic oils that attack polycarbonate — wipe it with a dry cloth. A filter removes water and particulate only; it does not regulate pressure or add lubrication.

Airtac B52-GF Copper-Free Pneumatic Air Treatment Component B52-GF30015MJW FAQ

We do not quote a single rated-flow number because AirTAC publishes GF-series flow only as pressure-drop curves. Share your operating pressure and air demand and we will confirm the sizing from the datasheet on request.

Pick 5 um when downstream devices need finer air - precision valves, spraying, instrumentation. Stay with the standard 40 um for general cylinder and valve protection where its longer service interval is an advantage. Both grades are listed for the GF300 series and the W suffix simply selects the fine element.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac B52-GF Copper-Free Pneumatic Air Treatment Component B52-GF30015MJW

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for B52-GF30015MJW and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.