AirTAC GL200 · Air Lubricator (oil-mist lubrication)

Airtac B52-GL Copper-Free Air Treatment Unit B52-GL20008J

The AirTAC Airtac B52-GL Copper-Free Air Treatment Unit B52-GL20008J is a genuine G-series air lubricator. It meters an oil mist into the compressed-air line so cylinders, valves and air tools downstream stay lubricated, with PT1/4" ports and a pc oil bowl. A lubricator does not filter or regulate — it goes last in the line, after the filter and the regulator.

  • TypeAir lubricator
  • Port sizePT1/4"
  • Inlet pressure0.05 - 1.0 MPa
  • Oil bowlPC
  • ThreadPT
  • BracketSupplied without bracket
$22.10 $26.33Save 16% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac B52-GL Copper-Free Air Treatment Unit B52-GL20008J

GL20008J is an AirTAC G-series air lubricator: its single function is to add a fine oil mist to the compressed air feeding downstream tools and actuators - it filters nothing and regulates nothing. This 200-size unit has a PT1/4" port, and the J suffix means it comes without a mounting bracket, suiting installations where the unit screws directly into a manifold, FRL set or machine port. It runs on compressed air only, accepts up to 1.0 MPa (145 psi) inlet, has a polycarbonate (PC) bowl at the 200 size, and operates at -5 to 70 C (non-freezing).

This is a genuine AirTAC part. The GL family is also offered in 300, 400 and 600 sizes with larger ports up to 1", in PT (standard), G (BSPP) or NPT threads, with or without a bracket, and with aluminium alloy bowls at the 600 size. AirTAC publishes flow as curves rather than a single rating, so we confirm flow and other datasheet figures on request.

Airtac B52-GL Copper-Free Air Treatment Unit B52-GL20008J Technical Specifications

ModelAirtac B52-GL Copper-Free Air Treatment Unit B52-GL20008J
SeriesGL200 air lubricator
Port sizePT1/4" (PT thread)
Oil bowl materialPC
BracketSupplied without bracket
FluidCompressed air
Inlet pressure0.05 - 1.0 MPa (7 - 145 psi)
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
FunctionOil-mist lubrication only

Specifications follow the official AirTAC G-series air-preparation data. A lubricator has no drain, no regulating mechanism, no gauge and no filter element, so none of those figures apply. Oil grade, bowl capacity, flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac B52-GL Copper-Free Air Treatment Unit B52-GL20008J

GL200G-series air lubricator, 200 body — sets the port range.
08Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4".
JSupplied without bracket. A bracket ships by default; J orders it without.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.

The lubricator has the shortest code of the six G-series subfamilies — size, port, bracket, thread. There is no drain, pressure-type, gauge or filtering-grade position. Example: GL300-10JG is a 300 body, PT3/8", no bracket, G (BSPP) thread.

Size Class

  • GL200PT1/8" - PT1/4"
  • GL300PT1/4" - PT1/2"
  • GL400PT3/8" - PT1/2"
  • GL600PT3/4" - PT1"

A larger body carries a larger port and passes more air. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GL600 uses an aluminium-alloy oil bowl; the 200, 300 and 400 bodies use PC.

This modelGL200 · PT1/4"
One size upGL300
Line orderFilter first, then regulator, lubricator last

Where the Airtac B52-GL Copper-Free Air Treatment Unit B52-GL20008J Is Used

handyman

Pneumatic nailer station

Threads straight into the supply fitting at a workshop bench feeding framing nailers and staplers, putting an oil mist into the air those tools need, with no bracket required for a direct-mount setup.

speed

High-cycle pick-and-place cylinders

Keeps the small-bore cylinders of a pick-and-place module on a packaging line supplied with lubricated air through rapid cycling, without adding filtration or regulation the circuit may already have upstream.

valve

Pneumatic valve actuation lines

Installed in the supply to quarter-turn pneumatic actuators so their internal seals receive lubrication across thousands of open-close cycles; the no-bracket format suits manifold mounting.

Is the Airtac B52-GL Copper-Free Air Treatment Unit B52-GL20008J the Right Lubricator?

GL units provide lubrication only; if the line also needs water and particulate removal or pressure control, add a GF filter and GR regulator, or step to a GC three-unit set or a GFC two-unit set that pairs a filter regulator with a lubricator. Size: 200 covers 1/8" and 1/4" ports; use 300 (3/8", 1/2"), 400 (3/4") or 600 (1") for larger flows. Bracket: J deletes it; GL20008 without the J includes one. Thread: PT here, with G (BSPP) and NPT as catalogue options to order. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Downstream equipment actually needs oil
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Bracket needed, or order with J
  • ✓ Bowl material: PC, or aluminium on GL600
  • ✓ Fit after the filter and regulator
Ask an Engineer

Installation & Maintenance Notes

  • check Fit last in the line: filter, then regulator, then lubricator.
  • check Mount vertically, bowl down, following the airflow arrow.
  • check Keep inlet pressure within 0.05 - 1.0 MPa.
  • check Use only oil approved for pneumatic lubricators.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Check the oil level regularly; top up before it runs dry.

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. The oil mist travels downstream, so if any branch of the line must stay oil-free, take that branch off before the lubricator. We will confirm the recommended oil grade from the factory datasheet on request.

Airtac B52-GL Copper-Free Air Treatment Unit B52-GL20008J FAQ

There is no single rated flow figure to quote: AirTAC publishes flow for the GL200 series as curves, not one number. Send us your line pressure and demanded flow and we will confirm sizing against the datasheet curves on request.

GL units only lubricate. If your line also needs water and particulate removal or pressure regulation, pair this unit with a GF filter and GR regulator, choose a GC three-unit set, or use a GFC two-unit set that combines a filter regulator with a lubricator. Also note the J in GL20008J means no bracket is included; GL20008 supplies one.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac B52-GL Copper-Free Air Treatment Unit B52-GL20008J

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for B52-GL20008J and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.