The AirTAC Airtac GAC F.R.L. Unit GAC400N10ALNW is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 3/8" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, regulated and lubricated air for downstream pneumatics, this GAC400 unit combines a filter, regulator and lubricator on a single L-shape bracket. The 3/8in port serves a 2390 g assembly that uses a 5 um element to trap fine particles before the 0.15-0.4 MPa (20-58 psi) lower-pressure range is set. A nylon bowl houses the automatic drain, which empties the 100 cc condensate sump without operator input.
Because the lubricator sits last in the sequence, oil mist is injected downstream of the regulator seat, preventing fouling of the internal pressure-control mechanism. No gauge is supplied, but the body features a 1/4in gauge connection if visual monitoring is added later. Spares follow the 400-10 suffix: GAF400-10, GAR400-10 and GAL400-10.
| Model | Airtac GAC F.R.L. Unit GAC400N10ALNW |
|---|---|
| Series | GAC400 F.R.L. combination |
| Port size | 3/8" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Nylon |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 2390 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC400 is 1/4" if you add one.
| GAC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/4" gauge connection. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF400-10 filter, GAR400-10 regulator, GAL400-10 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC400 · 3/8" · curve to 6000 L/min |
|---|---|
| One size down | GAC300 |
| One size up | GAC500 (curve to 7000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds low-pressure actuation and handling systems where a strict 0.15-0.4 MPa ceiling protects sensitive glassware and delicate instruments.
The 5 um element safeguards micro-solenoid and proportional valve nozzles from particulate ingress in fine-tolerance assembly jigs.
Provides steady low-force actuation for sealing and capping heads, with the automatic drain handling condensate during continuous shifts.
Choose this lower-pressure L-type assembly for machines operating strictly under 0.4 MPa; if the application may ever require higher force, the standard S-type is the correct choice. The 5 um W-grade element suits precision valves and instrument air, trading finer filtration for more frequent element service compared to the 40 um default. The automatic drain clears condensate from the 100 cc bowl unattended, a decisive feature for wet lines or remote installations. If the downstream line must remain oil-free, omit the lubricator and select a filter-regulator instead. The catalogue flow curve for the GAC400 is plotted to 6000 L/min at 0.7 MPa inlet, providing a sizing envelope that is double the 3000 L/min envelope of the GAC300. Keep in mind that 0.4 MPa is 44% of the standard 0.9 MPa ceiling.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This lower-pressure unit regulates from 0.15-0.4 MPa (20-58 psi) with a max pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It operates from -5 to 70 C, weighs 2390 g, features a 100 cc drain bowl and a 185 cc oil bowl, and uses ISO VG 32 lubricant.
The N in the ordering code indicates no gauge is supplied. The body has a 1/4in gauge connection machined in, allowing operators to install a compatible MPa/psi PT-thread gauge later to visually verify the 0.15-0.4 MPa setpoint.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.