The AirTAC Airtac GAC F.R.L. Unit GAC400N10ASNWK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 3/8" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, regulated and lubricated air for industrial pneumatics, this AirTAC GAC400N10ASNWK combines a filter, regulator and lubricator on a single L-shape bracket. The 3/8in port pairs with a standard 0.15-0.9 MPa (20-130 psi) operating range, while the 5 um element captures fine particulates for sensitive downstream valves. Because the lubricator sits last in the sequence, oil mist is introduced downstream of the regulator seat, preventing fouling of the pressure-control mechanism.
Weighing 2390 g, this body size demands a rigid panel or frame mount rather than tubing support. The unit carries a nylon bowl and an automatic drain that empties the 100 cc condensate sump without operator intervention. No pressure gauge is supplied, but a 1/4in connection is provided if you need to add one later. A reverse-flow (reflux) valve is fitted, shown in the catalogue as a separate pneumatic symbol on its own page.
| Model | Airtac GAC F.R.L. Unit GAC400N10ASNWK |
|---|---|
| Series | GAC400 F.R.L. combination |
| Port size | 3/8" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Nylon |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 2390 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC400 is 1/4" if you add one.
| GAC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/4" gauge connection. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF400-10 filter, GAR400-10 regulator, GAL400-10 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC400 · 3/8" · curve to 6000 L/min |
|---|---|
| One size down | GAC300 |
| One size up | GAC500 (curve to 7000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds sensitive pneumatic tool changers where the 5 um element protects precision valves from fine particulate ingress.
Conditions air for multi-station textile looms, utilizing the automatic drain to handle humid plant environments.
Supplies steady lubricated air to high-cycle carton sealing actuators, ensuring consistent movement and reducing wear.
This model uses a 5 um element instead of the standard 40 um, trading a slightly shorter service life for the cleaner air required by precision instruments. The automatic drain makes it suitable for unattended or high-moisture lines, while the nylon bowl offers a lightweight alternative to the standard PC or metal bowls. If your process requires absolutely oil-free air downstream, you must omit the lubricator and choose a dedicated filter-regulator instead. For maintenance, the assembly accepts individual GAF400-10, GAR400-10 and GAL400-10 replacement units. The catalogue flow curve for the GAC400 is plotted to 6000 L/min at 0.7 MPa inlet, which is double the GAC300's 3000 L/min envelope, giving you significant room to size up. Additionally, the 1.5 MPa (215 psi) proof pressure provides a 1.5x burst-test margin above the 1.0 MPa maximum, though this does not permit running above the rated ceiling.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This standard type unit regulates from 0.15-0.9 MPa (20-130 psi) with a maximum pressure of 1.0 MPa (145 psi) and a 1.5 MPa (215 psi) proof pressure. It operates from -5 to 70 C, weighs 2390 g, and features a 100 cc drain bowl with a 185 cc oil bowl. The recommended lubricant is ISO VG 32.
The N in the ordering code indicates no gauge is supplied. The body features a 1/4in gauge connection, allowing you to install a compatible pressure indicator if monitoring the 0.15-0.9 MPa setpoint is required for your application.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.