The AirTAC Airtac GAFC Air Service Unit GAFC20008ALK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/4" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
This GAFC20008ALK is a compact F.R.L. combination for a 1/4in air line, rated for lower-pressure duty from 0.15 to 0.4 MPa (20-58 psi). The filter and regulator share one body, so the set is two pieces on a T bracket, with the lubricator adding a metered oil mist after the pressure is set. It includes a 40 um element and a circular gauge reading MPa/psi.
The 25 cc condensate bowl and 36 cc oil bowl set the service rhythm for a 590 g unit, and the automatic drain clears water without an operator. A reverse-flow valve is fitted, and the catalogue flow curve for this body is plotted to 1750 L/min at 0.7 MPa inlet. With a 1.0 MPa maximum supply, there is about 0.6 MPa of headroom above the 0.4 MPa regulated ceiling.
| Model | Airtac GAFC Air Service Unit GAFC20008ALK |
|---|---|
| Series | GAFC200 F.R.L. combination |
| Port size | 1/4" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | PC |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 25 cc |
| Capacity of oil bowl | 36 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 590 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.
| GAFC200 | GA200 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 08 | Port size 1/4". This body offers 06 = 1/8", 08 = 1/4". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAFR200-08 filter & regulator, GAL200-08 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC200 · 1/4" · curve to 1750 L/min |
|---|---|
| One size up | GAFC300 (curve to 3500 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Feed a single-acting clamp or a small positioning jig with a stable 0.15-0.4 MPa supply, keeping delicate workpieces from being over-pushed.
Supply a low-pressure air knife or a lab test fixture where the 0.4 MPa ceiling prevents accidental over-pressure to fragile components.
Lubricate a small cylinder on a carton sealer or a bottle capper, with the automatic drain handling condensate from a humid plant line.
Choose this GAFC20008ALK when your machine needs a 1/4in port and a regulated output capped at 0.4 MPa (20-58 psi) - the L type suits gentle actuators or precision blow-off stations, not lines that may later demand more pressure. The PC bowl is the standard build, and the automatic drain suits unattended operation; the 40 um element handles general shop air. The PT thread carries a gauge scaled in MPa/psi, and the K code adds the reverse-flow valve as an ordering difference. If the line must stay oil-free, omit the lubricator and select a plain GAFR filter-regulator instead; otherwise, spares are the GAFR200-08 and GAL200-08. With 1.0 MPa max supply, the regulated band tops out at 0.4 MPa, so you have about 0.6 MPa of supply headroom above the setpoint.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR200-08 filter-regulator on that branch instead of the full combination.
It is a lower-pressure F.R.L. combination with a 1/4in port, working range 0.15-0.4 MPa (20-58 psi), max pressure 1.0 MPa (145 psi), proof pressure 1.5 MPa (215 psi), and a temperature range of -5 to 70 C. The drain bowl holds 25 cc, the oil bowl 36 cc, and the unit weighs 590 g. Use ISO VG 32 oil in the lubricator.
The L code sets the regulated output to 0.15-0.4 MPa instead of the standard 0.15-0.9 MPa. This suits applications that must never see high pressure, such as fine blow-off or light clamping. If your machine may need more than 0.4 MPa later, the L type is the wrong part - choose the S type instead.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.