The AirTAC Airtac GAFC Air Service Unit GAFC300C08ALK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/4" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
This GAFC300C08ALK is a two-piece F.R.L. combination: a filter-regulator body paired with a lubricator, mounted on a shared T-bracket with quick clamps. Air enters the first body where the 40 um element removes moisture and solid particles, and the regulator sets the pressure to a lower 0.15-0.4 MPa (20-58 psi) band. The lubricator then adds a metered oil mist downstream, so oil never travels back through the regulator seat.
The metal bowl (C code) holds 60 cc of condensate, while the separate oil bowl holds 98 cc. At 1020 g, this 1/4in unit suits a panel or frame mount rather than tubing support. The automatic drain clears collected water without an operator, and the fitted circular gauge reads in MPa/psi for the PT thread. A reverse-flow (reflux) valve is included, shown as a separate symbol in the catalogue.
| Model | Airtac GAFC Air Service Unit GAFC300C08ALK |
|---|---|
| Series | GAFC300 F.R.L. combination |
| Port size | 1/4" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Metal |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1020 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.
| GAFC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 08 | Port size 1/4". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAFR300-08 filter & regulator, GAL300-08 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC300 · 1/4" · curve to 3500 L/min |
|---|---|
| One size down | GAFC200 |
| One size up | GAFC400 (curve to 6000 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Feed a compact pneumatic press or clamping jig that operates below 0.4 MPa, where the lower-pressure regulator prevents over-pressuring delicate workpieces.
Supply a short conveyor's air cylinders with filtered, regulated air and a controlled oil mist, keeping moving parts lubricated without manual attention.
Prepare air for a laboratory fixture or test stand that needs clean, regulated air at modest pressure, with the automatic drain reducing maintenance between experiments.
Choose this GAFC300C08ALK when the line needs 1/4in ports and a regulated output capped at 0.4 MPa. The L type suits low-pressure circuits, but if the machine may ever require more than 0.4 MPa, select the standard S type instead. The metal bowl is a build choice; the common specification of 1.0 MPa max and -5 to 70 C applies to all bowl materials, so confirm the metal suits your surroundings. The automatic drain is decisive for unattended operation, and the reverse-flow valve is fitted per the K code. The gauge is supplied and reads MPa/psi for the PT thread. For oil-free air downstream, omit the lubricator and choose a plain GAFR300-08 filter-regulator; otherwise the lubricator needs ISO VG 32 oil. Replacement units are orderable separately as GAFR300-08 and GAL300-08. With a 1.0 MPa max supply, you have about 0.6 MPa above the 0.4 MPa top of the range, so plan the inlet pressure accordingly.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR300-08 filter-regulator on that branch instead of the full combination.
This F.R.L. combination operates at 0.15-0.4 MPa (20-58 psi), with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). The temperature range is -5 to 70 C. It has a 60 cc drain bowl and a 98 cc oil bowl, weighs 1020 g, and uses ISO VG 32 lubricant. The 40 um element filters the air, and the automatic drain clears condensate.
The L type regulates to a maximum of 0.4 MPa (58 psi), while the standard S type reaches 0.9 MPa (130 psi). This model is capped at 0.4 MPa, so it suits low-pressure circuits only. If your application may need higher pressure, the S type is the correct choice. The lower ceiling means the 1.0 MPa max supply leaves about 0.6 MPa of headroom above the regulated band.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.