verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GAFC300 · F.R.L. Combination (Filter-Regulator + Lubricator)

Airtac GAFC Air Service Unit GAFC300C08ALWK

The AirTAC Airtac GAFC Air Service Unit GAFC300C08ALWK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/4" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).

  • TypeF.R.L. combination
  • Port size1/4"
  • Pressure range0.15 - 0.4 MPa (20 - 58 psi)
  • Filtering grade5 µm
  • Bowl materialMetal
  • Drainautomatic
  • Pressure gaugeCircular, MPa / psi
  • Weight1020 g
$95.07 $105.17Save 9% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GAFC Air Service Unit GAFC300C08ALWK

This AirTAC GAFC300C08ALWK is a two-piece F.R.L. combination: the filter and regulator share one metal-bowl body, and the lubricator is mounted on the same T-bracket. With a 1/4in port and 5 um element, it cleans and meters oil mist for a compact pneumatic circuit.

The lower-pressure regulator is set for 0.15-0.4 MPa (20-58 psi), and the 60 cc condensate bowl plus 98 cc oil bowl define the service rhythm. The automatic drain clears water without an operator, and the fitted circular gauge reads in MPa/psi for the PT thread.

Airtac GAFC Air Service Unit GAFC300C08ALWK Technical Specifications

ModelAirtac GAFC Air Service Unit GAFC300C08ALWK
SeriesGAFC300 F.R.L. combination
Port size1/4" (PT thread)
Filtering grade5 µm
Pressure range0.15 - 0.4 MPa (20 - 58 psi)
TypeLower pressure
Bowl materialMetal
Drain typeAutomatic drain
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl60 cc
Capacity of oil bowl98 cc
Recommended lubricantISO VG 32 or equivalent
Weight1020 g

Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.

Model Code: Airtac GAFC Air Service Unit GAFC300C08ALWK

GAFC300GA300 series F.R.L. unit — sets ports, bowl capacity and weight.
CBowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N).
08Port size 1/4". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2".
ADrain: Automatic drain.
LLower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L).
(blank)Circular pressure gauge fitted.
WFiltering grade 5 µm.
(blank)PT thread; gauge scale MPa / psi.
KReverse-flow (reflux) valve attached.

Constituent units, orderable separately as spares: GAFR300-08 filter & regulator, GAL300-08 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.

Size Class & Flow Envelope

  • GAFC2001/8"-1/4" · 1750 L/min
  • GAFC3001/4"-1/2" · 3500 L/min
  • GAFC4003/8"-1/2" · 6000 L/min
  • GAFC5003/4" · 7000 L/min
  • GAFC6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.

This modelGAFC300 · 1/4" · curve to 3500 L/min
One size downGAFC200
One size upGAFC400 (curve to 6000 L/min)
Build orderFilter & regulator → bracket → lubricator

Where the Airtac GAFC Air Service Unit GAFC300C08ALWK Is Used

precision_manufacturing

Precision assembly fixtures

Feed a 1/4in line to a benchtop press or clamping fixture where a 5 um element protects fine metering valves and the lower pressure range prevents over-force on delicate parts.

science

Laboratory air benches

Supply a lab workstation with filtered, regulated air at 0.15-0.4 MPa for pneumatic actuators on test rigs, where the automatic drain keeps condensate out of sensitive instruments.

handyman

Maintenance shop air tools

Run a small parts washer or blow-off station from a 1/4in drop, using the 5 um element to keep tool internals clean and the metal bowl for a shop-floor environment.

Is the Airtac GAFC Air Service Unit GAFC300C08ALWK the Right Air-Prep Unit?

The GAFC300 body suits 1/4in lines and weighs 1020 g, with the catalogue flow curve plotted to 3500 L/min at 0.7 MPa inlet. The metal bowl is a build choice; the shared specification of 1.0 MPa max and -5 to 70 C does not change with material, so confirm it suits your surroundings. The automatic drain handles wet lines, while the 5 um element traps finer particles than the standard 40 um but needs more frequent service. The reverse-flow valve is fitted per the K code. Spares are orderable as GAFR300-08 and GAL300-08. Since this is the lower-pressure type, it tops out at 0.4 MPa; the 1.0 MPa max supply leaves about 0.6 MPa above the 0.4 MPa top of the range.

Quick checklist

  • ✓ Body size for your peak flow (1/4" here)
  • ✓ Standard 0.9 MPa or lower-pressure 0.4 MPa
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Element 40 µm or 5 µm
  • ✓ Thread & gauge scale (PT / G / NPT)
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter-regulator first, lubricator last.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Fill the oil bowl with ISO VG 32 or equivalent only.
  • check Drain condensate before the 60 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 1020 g unit on its bracket, not on the tubing.

The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR300-08 filter-regulator on that branch instead of the full combination.

Airtac GAFC Air Service Unit GAFC300C08ALWK FAQ

This F.R.L. combination operates at 0.15-0.4 MPa (20-58 psi), with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). The temperature range is -5 to 70 C, and the recommended lubricant is ISO VG 32. It has a 60 cc drain bowl and a 98 cc oil bowl, and the complete unit weighs 1020 g.

The C code specifies a metal bowl, which is a build choice for the surrounding environment; the catalogue does not rate one material as stronger than another. The W code means a 5 um element is fitted, which traps finer particles than the standard 40 um for cleaner air to sensitive components, though it will need more frequent replacement.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GAFC Air Service Unit GAFC300C08ALWK

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for GAFC300C08ALWK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.