The AirTAC Airtac GAFC Air Service Unit GAFC300C08AS is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/4" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
This GAFC300C08AS is a two-piece F.R.L. combination: a filter-regulator body paired with a lubricator, mounted on a shared T-bracket with quick clamps. The 1/4in port size and 1020 g mass place it in the mid-range class, suitable for feeding a single machine station or a small bank of actuators.
Air enters the first body where the 40 um element removes solids and moisture, and the regulator sets pressure to 0.15-0.9 MPa (20-130 psi). The lubricator then adds a controlled oil mist downstream, so oil never travels back through the regulator seat. With a metal bowl and automatic drain, this unit suits lines where condensate must clear itself without an operator.
| Model | Airtac GAFC Air Service Unit GAFC300C08AS |
|---|---|
| Series | GAFC300 F.R.L. combination |
| Port size | 1/4" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Metal |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1020 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.
| GAFC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 08 | Port size 1/4". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAFR300-08 filter & regulator, GAL300-08 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC300 · 1/4" · curve to 3500 L/min |
|---|---|
| One size down | GAFC200 |
| One size up | GAFC400 (curve to 6000 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Feed a bank of solenoid valves on a CNC lathe that need regulated air at 0.6 MPa and a fine oil mist for slideway lubrication.
Condition air for a bench-top press and its pneumatic clamps in a small assembly cell, where the 60 cc bowl handles a shift of condensate.
Supply a carton erector's cylinders and grippers with filtered, regulated, lubricated air, with the automatic drain reducing maintenance on a busy line.
The metal bowl (C code) is a build choice for this unit; the shared specification of 1.0 MPa max pressure and -5 to 70 C applies regardless of bowl material, so confirm it suits your environment. The automatic drain clears condensate continuously, which is decisive for unattended operation. A circular gauge is fitted, reading MPa/psi for the default PT thread. The 40 um element handles general shop air; choose the W option for 5 um filtration if you feed precision valves. Replacement internals are orderable as GAFR300-08 and GAL300-08. With a 1.0 MPa max supply, there is only about 0.1 MPa of headroom above the 0.9 MPa top of the regulated range, so plan your inlet pressure accordingly.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR300-08 filter-regulator on that branch instead of the full combination.
The working pressure range is 0.15-0.9 MPa (20-130 psi). Maximum pressure is 1.0 MPa (145 psi) and proof pressure is 1.5 MPa (215 psi). Operating temperature is -5 to 70 C. The drain bowl holds 60 cc and the oil bowl holds 98 cc. Recommended lubricant is ISO VG 32. The unit weighs 1020 g.
The A code specifies an automatic drain, which expels condensate from the 60 cc bowl without manual intervention. This is ideal for installations where the unit is mounted out of reach or on lines with high moisture content, as it prevents water buildup from reaching downstream components.