The AirTAC Airtac GAFC Air Service Unit GAFC300C10ALNW is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 3/8" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
This GAFC300C10ALNW is a two-piece F.R.L. combination: a filter and regulator share one body, and a lubricator is joined on a T-bracket. The 3/8in port, 1020 g unit preps air for a single machine or a small line, with a 5 um element trapping fine particles before the pressure is set.
The lower-pressure type regulates from 0.15 to 0.4 MPa (20-58 psi), with a 1.0 MPa (145 psi) maximum supply. The metal bowl and automatic drain handle condensate without an operator, while the 60 cc drain bowl and 98 cc oil bowl define the service interval. A gauge is not fitted; the 1/8in gauge connection is ready for one if needed.
| Model | Airtac GAFC Air Service Unit GAFC300C10ALNW |
|---|---|
| Series | GAFC300 F.R.L. combination |
| Port size | 3/8" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Metal |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1020 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFC300 is 1/8" if you add one.
| GAFC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAFR300-10 filter & regulator, GAL300-10 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC300 · 3/8" · curve to 3500 L/min |
|---|---|
| One size down | GAFC200 |
| One size up | GAFC400 (curve to 6000 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
The 5 um element and lower-pressure range suit a precision pneumatic valve on a small assembly fixture, where fine filtration and a 0.4 MPa ceiling protect sensitive components.
Feed a single-station drilling or tapping machine with filtered, regulated air and a metered oil mist, keeping the tool cylinder lubricated without over-oiling the line.
On a lab test bench, the automatic drain and metal bowl handle condensate from a wet compressor line, while the 5 um element protects test gauges and orifices from fine debris.
Choose the GAFC300 body for medium flows, with the 3/8in port feeding actuators or small headers. The metal bowl is a build choice; the catalogue gives no impact or chemical data, so confirm it suits your surroundings. The automatic drain clears condensate without an operator, ideal for wet or unattended lines. The 5 um element suits precision valves but needs more frequent service than the 40 um standard. The L type tops out at 0.4 MPa, so if the machine may need more pressure, select the S type instead. The PT thread and no-gauge spec mean adding a gauge later requires the 1/8in connection. Spares are the GAFR300-10 filter-regulator and the GAL300-10 lubricator, both orderable separately. The 1.0 MPa max supply leaves about 0.6 MPa above the 0.4 MPa top of the range, so plan the inlet pressure carefully for full regulation.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR300-10 filter-regulator on that branch instead of the full combination.
The working pressure range is 0.15-0.4 MPa (20-58 psi), with a maximum supply of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). It operates from -5 to 70 C and uses ISO VG 32 lubricant. The drain bowl holds 60 cc and the oil bowl 98 cc, with a total weight of 1020 g.
The N in the code means no gauge is supplied. The GAFC300 body has a 1/8in gauge connection, so you can add a circular gauge later if you need to read the set pressure. The thread is PT, and a gauge added would read in MPa and psi.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.