The AirTAC Airtac GAFC Air Service Unit GAFC300C10ALW is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 3/8" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
This GAFC300C10ALW is a two-piece F.R.L. combination: a filter-regulator body paired with a lubricator on a shared T-bracket. The 3/8in port and 1020 g mass place it in the mid-range class, sized for a machine station rather than a single small cylinder. The metal bowl holds 60 cc of condensate, while the oil bowl holds 98 cc, so the service interval is set by how often the line is wet.
The lower-pressure regulator tops out at 0.4 MPa (20-58 psi), which suits gentle clamping or air-bearing circuits. The 5 um element traps finer particles than the standard 40 um grade, protecting precision valves downstream. A circular gauge is fitted, reading MPa/psi for the PT thread. The automatic drain clears water without an operator, which matters on a line that runs unattended.
| Model | Airtac GAFC Air Service Unit GAFC300C10ALW |
|---|---|
| Series | GAFC300 F.R.L. combination |
| Port size | 3/8" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Metal |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1020 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.
| GAFC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAFR300-10 filter & regulator, GAL300-10 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC300 · 3/8" · curve to 3500 L/min |
|---|---|
| One size down | GAFC200 |
| One size up | GAFC400 (curve to 6000 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Feed a 3/8in line to an air-bearing spindle that needs a stable 0.3 MPa supply. The 5 um element keeps fine particles out of the bearing gap, and the lower-pressure regulator prevents over-pressurization.
Regulate the pneumatic brake on a film winder to 0.25 MPa for consistent tension. The automatic drain clears condensate from the 60 cc bowl during long packaging runs, and the metal bowl handles the factory floor.
Supply a lab test rig that uses a 0.2 MPa air cushion. The lower-pressure range gives fine adjustment below 0.4 MPa, and the 98 cc oil bowl keeps a small lubricator running for weeks between refills.
Choose this GAFC300C10ALW when the circuit needs a soft 0.15-0.4 MPa ceiling and fine filtration. The L type is the wrong part if the machine may ever need more than 0.4 MPa, since the regulator cannot go higher. The metal bowl is a build choice, not a performance upgrade, and the shared specification of 1.0 MPa max and -5 to 70 C applies to all bowl materials, so confirm the metal suits your environment. The automatic drain removes condensate by itself, and the 5 um element suits instrument air but will need more frequent service than a 40 um grade. Spares are orderable as the GAFR300-10 filter & regulator and the GAL300-10 lubricator. With a 1.0 MPa max supply, there is about 0.6 MPa of headroom above the 0.4 MPa top of the range, so plan the inlet pressure accordingly.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR300-10 filter-regulator on that branch instead of the full combination.
This F.R.L. combination works with air only, filtering to 5 um. The lower-pressure regulator range is 0.15-0.4 MPa (20-58 psi), with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). It operates from -5 to 70 C and must not freeze. The drain bowl holds 60 cc, the oil bowl 98 cc, and the unit weighs 1020 g. Use ISO VG 32 oil in the lubricator.
The C code specifies a metal bowl, which is a build choice for the installation environment. The A code means the drain is automatic, so it clears condensate from the 60 cc bowl without an operator. The catalogue gives no performance difference between bowl materials, so confirm the metal suits your surroundings. The automatic drain is useful for lines that run unattended or in wet conditions.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.