verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GAFC300 · F.R.L. Combination (Filter-Regulator + Lubricator)

Airtac GAFC Air Service Unit GAFC300C10ASK

The AirTAC Airtac GAFC Air Service Unit GAFC300C10ASK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 3/8" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination
  • Port size3/8"
  • Pressure range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • Bowl materialMetal
  • Drainautomatic
  • Pressure gaugeCircular, MPa / psi
  • Weight1020 g
$95.07 $105.17Save 9% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GAFC Air Service Unit GAFC300C10ASK

This GAFC300C10ASK is a two-piece F.R.L. combination: a filter-regulator body paired with a lubricator, mounted on a shared T-bracket with quick clamps. The 3/8in port size and 1020 g mass place it in the mid-range class, suitable for feeding a single machine station or a small bank of actuators.

Air enters the first body where the 40 um element removes solids and moisture, and the regulator sets pressure within 0.15-0.9 MPa (20-130 psi). The lubricator then adds a metered oil mist downstream, so oil never travels back through the regulator seat. The metal bowl is specified by the C code, and the automatic drain clears condensate without operator intervention.

Airtac GAFC Air Service Unit GAFC300C10ASK Technical Specifications

ModelAirtac GAFC Air Service Unit GAFC300C10ASK
SeriesGAFC300 F.R.L. combination
Port size3/8" (PT thread)
Filtering grade40 µm
Pressure range0.15 - 0.9 MPa (20 - 130 psi)
TypeStandard
Bowl materialMetal
Drain typeAutomatic drain
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl60 cc
Capacity of oil bowl98 cc
Recommended lubricantISO VG 32 or equivalent
Weight1020 g

Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.

Model Code: Airtac GAFC Air Service Unit GAFC300C10ASK

GAFC300GA300 series F.R.L. unit — sets ports, bowl capacity and weight.
CBowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N).
10Port size 3/8". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2".
ADrain: Automatic drain.
SStandard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L).
(blank)Circular pressure gauge fitted.
(blank)Filtering grade 40 µm.
(blank)PT thread; gauge scale MPa / psi.
KReverse-flow (reflux) valve attached.

Constituent units, orderable separately as spares: GAFR300-10 filter & regulator, GAL300-10 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.

Size Class & Flow Envelope

  • GAFC2001/8"-1/4" · 1750 L/min
  • GAFC3001/4"-1/2" · 3500 L/min
  • GAFC4003/8"-1/2" · 6000 L/min
  • GAFC5003/4" · 7000 L/min
  • GAFC6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.

This modelGAFC300 · 3/8" · curve to 3500 L/min
One size downGAFC200
One size upGAFC400 (curve to 6000 L/min)
Build orderFilter & regulator → bracket → lubricator

Where the Airtac GAFC Air Service Unit GAFC300C10ASK Is Used

precision_manufacturing

CNC coolant valve control

Feed a 3/8in line to a solenoid manifold controlling coolant jets on a small CNC mill, where the automatic drain keeps the bowl clear during long unattended runs.

factory

Assembly station air prep

Supply a bench-top assembly station with filtered, regulated air for pneumatic screwdrivers and push-in fittings, with the metal bowl resisting accidental knocks from tools.

engineering

Packaging line actuator bank

Power a series of 3/8in ported cylinders on a carton-erecting machine, using the 0.15-0.9 MPa range to set consistent force for film wrapping and sealing heads.

Is the Airtac GAFC Air Service Unit GAFC300C10ASK the Right Air-Prep Unit?

The GAFC300 body offers 1/4in, 3/8in and 1/2in port options; this 3/8in version balances flow capacity against fitting size for typical shop air lines. The metal bowl is a build choice for environments where the buyer prefers non-transparent construction, though the catalogue lists identical pressure and temperature limits for all bowl materials, so confirm compatibility for your specific surroundings. The automatic drain suits unattended operation, and the fitted circular gauge reads in MPa and psi for the default PT thread. The reverse-flow (reflux) valve is included per the K code. Spare parts are orderable as GAFR300-10 and GAL300-10. The 1.0 MPa max supply leaves about 0.1 MPa above the 0.9 MPa top of the regulated range, so plan inlet pressure accordingly if you need the full output.

Quick checklist

  • ✓ Body size for your peak flow (3/8" here)
  • ✓ Standard 0.9 MPa or lower-pressure 0.4 MPa
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Element 40 µm or 5 µm
  • ✓ Thread & gauge scale (PT / G / NPT)
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter-regulator first, lubricator last.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Fill the oil bowl with ISO VG 32 or equivalent only.
  • check Drain condensate before the 60 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 1020 g unit on its bracket, not on the tubing.

The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR300-10 filter-regulator on that branch instead of the full combination.

Airtac GAFC Air Service Unit GAFC300C10ASK FAQ

This F.R.L. combination operates on air from 0.15-0.9 MPa (20-130 psi), with a maximum pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). The temperature range is -5 to 70 C. It has a 60 cc drain bowl and a 98 cc oil bowl, weighs 1020 g, and uses ISO VG 32 lubricant. The 40 um filter element and automatic drain are standard for this code.

The K code specifies that a reverse-flow (reflux) valve is fitted to the assembly. The catalogue shows this as a separate pneumatic symbol in the circuit diagram. It is an ordering difference from the base model, and its detailed function is covered on a separate page in the catalogue.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GAFC Air Service Unit GAFC300C10ASK

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for GAFC300C10ASK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.