The AirTAC Airtac GAFC Air Service Unit GAFC300C10LN is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 3/8" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
This GAFC300 F.R.L. combination pairs a filter-regulator with a lubricator on a single T-bracket, so you get three functions from two pieces. The 3/8in port and 1020 g mass place it in the mid-size class, and the metal bowl is specified for this build. Its lower-pressure regulator is set for 0.15-0.4 MPa (20-58 psi), with a 40 um element protecting downstream components.
The filter and regulator share one body, so air is cleaned and set to pressure before the lubricator adds a metered oil mist last. The 60 cc condensate bowl and 98 cc oil bowl define the service interval, while the 1/8in gauge connection lets you add a pressure readout if needed. With no gauge fitted, the set pressure cannot be read without adding one.
| Model | Airtac GAFC Air Service Unit GAFC300C10LN |
|---|---|
| Series | GAFC300 F.R.L. combination |
| Port size | 3/8" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Metal |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1020 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFC300 is 1/8" if you add one.
| GAFC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAFR300-10 filter & regulator, GAL300-10 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC300 · 3/8" · curve to 3500 L/min |
|---|---|
| One size down | GAFC200 |
| One size up | GAFC400 (curve to 6000 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Feed a clamping jig on a benchtop assembly station where the regulator is set to 0.3 MPa to avoid crushing delicate parts. The metal bowl suits a shop floor with occasional coolant splash.
Supply a low-pressure line to a paint booth's atomizing nozzles, where the 0.4 MPa ceiling keeps the spray pattern consistent. The 40 um element traps particles before they reach the nozzle.
Run a pneumatic test bench that needs a stable low-pressure source for calibration fixtures. The 60 cc drain bowl handles condensate from a humid compressor line, and the manual drain lets the operator purge on schedule.
Choose the GAFC300C10LN when your line needs a 3/8in port and a lower regulated pressure, with a metal bowl and no gauge. The L type tops out at 0.4 MPa, so if the machine may ever need more, this is the wrong part. The semi-auto drain dumps condensate on each pressure drop, and the manual drain works on demand. Spare units are orderable separately as the GAFR300-10 filter & regulator and the GAL300-10 lubricator. With a 1.0 MPa max supply, you have about 0.6 MPa above the 0.4 MPa top of the range, so plan the inlet pressure carefully.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR300-10 filter-regulator on that branch instead of the full combination.
This F.R.L. combination operates at 0.15-0.4 MPa (20-58 psi) with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). It has a 3/8in port, 40 um element, 60 cc drain bowl, 98 cc oil bowl, and weighs 1020 g. The temperature range is -5 to 70 C, and the recommended lubricant is ISO VG 32.
The C code specifies a metal bowl, a build choice you should confirm suits your surroundings, as the catalogue gives no material-specific ratings. The N after the port means no gauge is supplied, so you cannot read the set pressure without adding one to the 1/8in gauge connection.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.