verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GAFC300 · F.R.L. Combination (Filter-Regulator + Lubricator)

Airtac GAFC Air Service Unit GAFC300C10SNK

The AirTAC Airtac GAFC Air Service Unit GAFC300C10SNK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 3/8" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination
  • Port size3/8"
  • Pressure range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • Bowl materialMetal
  • Drainsemi-auto + manual
  • Pressure gaugeNot fitted
  • Weight1020 g
$80.92 $90.07Save 10% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GAFC Air Service Unit GAFC300C10SNK

This AirTAC GAFC300C10SNK is a two-piece F.R.L. combination: the filter and pressure regulator share one body, and a separate lubricator is mounted on the same T-bracket. The 3/8in port size and 1020 g mass place it in the mid-range class, between the lighter GAFC200 and the heavier GAFC400. It operates at 0.15-0.9 MPa (20-130 psi) and filters to 40 um.

The metal bowl is specified by the C code, a build choice for the unit's environment. With a 60 cc condensate bowl and a 98 cc oil bowl, the service interval is set by how much moisture and oil the application consumes. The reverse-flow valve is fitted per the K code. The gauge is not supplied, but the 1/8in gauge connection is ready for one if you need to read the set pressure.

Airtac GAFC Air Service Unit GAFC300C10SNK Technical Specifications

ModelAirtac GAFC Air Service Unit GAFC300C10SNK
SeriesGAFC300 F.R.L. combination
Port size3/8" (PT thread)
Filtering grade40 µm
Pressure range0.15 - 0.9 MPa (20 - 130 psi)
TypeStandard
Bowl materialMetal
Drain typeSemi-auto drain + manual drain
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl60 cc
Capacity of oil bowl98 cc
Recommended lubricantISO VG 32 or equivalent
Weight1020 g

Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFC300 is 1/8" if you add one.

Model Code: Airtac GAFC Air Service Unit GAFC300C10SNK

GAFC300GA300 series F.R.L. unit — sets ports, bowl capacity and weight.
CBowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N).
10Port size 3/8". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2".
(blank)Drain: Semi-auto drain + manual drain.
SStandard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L).
NNo pressure gauge; 1/8" gauge connection.
(blank)Filtering grade 40 µm.
(blank)PT thread; gauge scale MPa / psi.
KReverse-flow (reflux) valve attached.

Constituent units, orderable separately as spares: GAFR300-10 filter & regulator, GAL300-10 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.

Size Class & Flow Envelope

  • GAFC2001/8"-1/4" · 1750 L/min
  • GAFC3001/4"-1/2" · 3500 L/min
  • GAFC4003/8"-1/2" · 6000 L/min
  • GAFC5003/4" · 7000 L/min
  • GAFC6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.

This modelGAFC300 · 3/8" · curve to 3500 L/min
One size downGAFC200
One size upGAFC400 (curve to 6000 L/min)
Build orderFilter & regulator → bracket → lubricator

Where the Airtac GAFC Air Service Unit GAFC300C10SNK Is Used

precision_manufacturing

Precision machining center

Feed a 3/8in line to a CNC spindle air curtain or a tool changer mechanism. The 40 um filtration protects sensitive valves, and the regulated pressure keeps actuation consistent.

factory

Assembly station air supply

Supply a multi-fixture assembly bench where operators use pneumatic screwdrivers and push cylinders. The 98 cc oil bowl supports continuous lubrication for the tools.

build

Packaging line tensioner

Run a film tensioning cylinder on a packaging machine. The metal bowl resists accidental impacts in a busy line, and the 60 cc condensate bowl handles typical moisture loads.

Is the Airtac GAFC Air Service Unit GAFC300C10SNK the Right Air-Prep Unit?

Choose the GAFC300 body for a 3/8in port with a 3500 L/min flow curve plotted at 0.7 MPa inlet, a step up from the GAFC200's 1750 L/min envelope. The C code specifies a metal bowl; the shared specification of 1.0 MPa max and -5 to 70 C does not change with material, so confirm the metal suits your surroundings. This model has the semi-auto drain that dumps on pressure drop plus a manual drain for on-demand use, and the 40 um element is the standard grade. The N code means no gauge is fitted; the 1/8in connection allows one to be added. The K code includes the reverse-flow valve, which the catalogue shows as a separate pneumatic symbol. The two units are orderable separately as GAFR300-10 and GAL300-10. With a 1.0 MPa max supply, there is about 0.1 MPa above the 0.9 MPa top of the regulated range, so plan a supply near 1.0 MPa if you need the full 0.9 MPa output.

Quick checklist

  • ✓ Body size for your peak flow (3/8" here)
  • ✓ Standard 0.9 MPa or lower-pressure 0.4 MPa
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Element 40 µm or 5 µm
  • ✓ Thread & gauge scale (PT / G / NPT)
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter-regulator first, lubricator last.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Fill the oil bowl with ISO VG 32 or equivalent only.
  • check Drain condensate before the 60 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 1020 g unit on its bracket, not on the tubing.

The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR300-10 filter-regulator on that branch instead of the full combination.

Airtac GAFC Air Service Unit GAFC300C10SNK FAQ

The working pressure range is 0.15-0.9 MPa (20-130 psi), with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). It operates from -5 to 70 C and must not freeze. The condensate bowl holds 60 cc and the oil bowl holds 98 cc. Recommended lubricant is ISO VG 32. The unit weighs 1020 g.

The N after the port code means no gauge is supplied. The GAFC300 body has a 1/8in gauge connection, so you can fit a compatible gauge if you need to read the outlet pressure. The default PT thread uses a gauge scale of MPa/psi.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GAFC Air Service Unit GAFC300C10SNK

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for GAFC300C10SNK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.