The AirTAC Airtac GAFC Air Service Unit GAFC300N08ALK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/4" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).

  • TypeF.R.L. combination
  • Port size1/4"
  • Pressure range0.15 - 0.4 MPa (20 - 58 psi)
  • Filtering grade40 µm
  • Bowl materialNylon
  • Drainautomatic
  • Pressure gaugeCircular, MPa / psi
  • Weight1020 g
$95.07 $105.17Save 9% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GAFC Air Service Unit GAFC300N08ALK

This AirTAC unit pairs a filter-regulator with a lubricator on a single T-bracket, so the air is cleaned and set to pressure before a metered oil mist is added downstream. The GAFC300N08ALK uses a 1/4in port, regulates from 0.15 to 0.4 MPa (20-58 psi), and filters down to 40 um.

The nylon bowl holds 60 cc of condensate while the separate oil bowl holds 98 cc, and the whole assembly weighs 1020 g. A circular gauge is fitted with an MPa/psi scale, and the automatic drain clears water without an operator.

Airtac GAFC Air Service Unit GAFC300N08ALK Technical Specifications

ModelAirtac GAFC Air Service Unit GAFC300N08ALK
SeriesGAFC300 F.R.L. combination
Port size1/4" (PT thread)
Filtering grade40 µm
Pressure range0.15 - 0.4 MPa (20 - 58 psi)
TypeLower pressure
Bowl materialNylon
Drain typeAutomatic drain
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl60 cc
Capacity of oil bowl98 cc
Recommended lubricantISO VG 32 or equivalent
Weight1020 g

Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.

Model Code: Airtac GAFC Air Service Unit GAFC300N08ALK

GAFC300GA300 series F.R.L. unit — sets ports, bowl capacity and weight.
NBowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N).
08Port size 1/4". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2".
ADrain: Automatic drain.
LLower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L).
(blank)Circular pressure gauge fitted.
(blank)Filtering grade 40 µm.
(blank)PT thread; gauge scale MPa / psi.
KReverse-flow (reflux) valve attached.

Constituent units, orderable separately as spares: GAFR300-08 filter & regulator, GAL300-08 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.

Size Class & Flow Envelope

  • GAFC2001/8"-1/4" · 1750 L/min
  • GAFC3001/4"-1/2" · 3500 L/min
  • GAFC4003/8"-1/2" · 6000 L/min
  • GAFC5003/4" · 7000 L/min
  • GAFC6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.

This modelGAFC300 · 1/4" · curve to 3500 L/min
One size downGAFC200
One size upGAFC400 (curve to 6000 L/min)
Build orderFilter & regulator → bracket → lubricator

Where the Airtac GAFC Air Service Unit GAFC300N08ALK Is Used

precision_manufacturing

Precision Fixture Clamping

Feed a small pneumatic vise or work-holding fixture on a benchtop assembly station, where the lower pressure range prevents over-clamping delicate parts.

science

Laboratory Air Supply

Provide filtered and regulated air to a lab test rig or a single air-operated valve, with the automatic drain keeping the line clear during long experiments.

handyman

Maintenance Shop Tools

Supply a small air drill or a blow gun in a maintenance bay, where the 1/4in port and lower pressure range suit light intermittent use.

Is the Airtac GAFC Air Service Unit GAFC300N08ALK the Right Air-Prep Unit?

Choose this lower-pressure model when your circuit never needs more than 0.4 MPa, such as light assembly or small actuator work. The nylon bowl is a build choice, but the shared -5 to 70 C and 1.0 MPa limits apply to all bowl materials, so confirm it suits your environment. The automatic drain suits unattended lines, and the 40 um element handles standard shop air. A reverse-flow (reflux) valve is fitted, and the PT thread comes with an MPa/psi gauge. The filter-regulator and lubricator are orderable separately as GAFR300-08 and GAL300-08. With a 1.0 MPa max supply, you have about 0.6 MPa of headroom above the 0.4 MPa top of the regulated band.

Quick checklist

  • ✓ Body size for your peak flow (1/4" here)
  • ✓ Standard 0.9 MPa or lower-pressure 0.4 MPa
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Element 40 µm or 5 µm
  • ✓ Thread & gauge scale (PT / G / NPT)
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter-regulator first, lubricator last.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Fill the oil bowl with ISO VG 32 or equivalent only.
  • check Drain condensate before the 60 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 1020 g unit on its bracket, not on the tubing.

The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR300-08 filter-regulator on that branch instead of the full combination.

Airtac GAFC Air Service Unit GAFC300N08ALK FAQ

The GAFC300N08ALK is an F.R.L. combination with a 1/4in port. It regulates from 0.15 to 0.4 MPa (20-58 psi), with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). The temperature range is -5 to 70 C, and it uses ISO VG 32 oil. The drain bowl holds 60 cc, the oil bowl holds 98 cc, and the unit weighs 1020 g.

The K indicates a reverse-flow (reflux) valve is fitted to this unit. It is shown as a separate pneumatic symbol in the catalogue, and it is included as an ordering difference. The filter-regulator and lubricator are still the two main serviceable parts, orderable as GAFR300-08 and GAL300-08.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GAFC Air Service Unit GAFC300N08ALK

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for GAFC300N08ALK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.