verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GAFC300 · F.R.L. Combination (Filter-Regulator + Lubricator)

Airtac GAFC Air Service Unit GAFC300N08ALW

The AirTAC Airtac GAFC Air Service Unit GAFC300N08ALW is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/4" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).

  • TypeF.R.L. combination
  • Port size1/4"
  • Pressure range0.15 - 0.4 MPa (20 - 58 psi)
  • Filtering grade5 µm
  • Bowl materialNylon
  • Drainautomatic
  • Pressure gaugeCircular, MPa / psi
  • Weight1020 g
$84.17 $93.54Save 10% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GAFC Air Service Unit GAFC300N08ALW

The GAFC300N08ALW is a two-piece F.R.L. combination: a filter-regulator body paired with a lubricator, mounted on a shared T-bracket with quick clamps. Air enters the 1/4in port, passes through the 5 um element, and is regulated down to the lower 0.15-0.4 MPa (20-58 psi) band before the lubricator meters oil mist into the stream last.

This nylon-bowl unit carries a 60 cc condensate bowl and a 98 cc oil bowl, weighing 1020 g. The automatic drain clears collected water without operator attention, while the fitted circular gauge reads in MPa and psi. The catalogue flow curve plots to 3500 L/min at 0.7 MPa inlet, useful for relative sizing rather than as a rated capacity.

Airtac GAFC Air Service Unit GAFC300N08ALW Technical Specifications

ModelAirtac GAFC Air Service Unit GAFC300N08ALW
SeriesGAFC300 F.R.L. combination
Port size1/4" (PT thread)
Filtering grade5 µm
Pressure range0.15 - 0.4 MPa (20 - 58 psi)
TypeLower pressure
Bowl materialNylon
Drain typeAutomatic drain
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl60 cc
Capacity of oil bowl98 cc
Recommended lubricantISO VG 32 or equivalent
Weight1020 g

Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.

Model Code: Airtac GAFC Air Service Unit GAFC300N08ALW

GAFC300GA300 series F.R.L. unit — sets ports, bowl capacity and weight.
NBowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N).
08Port size 1/4". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2".
ADrain: Automatic drain.
LLower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L).
(blank)Circular pressure gauge fitted.
WFiltering grade 5 µm.
(blank)PT thread; gauge scale MPa / psi.
(blank)No reverse-flow valve.

Constituent units, orderable separately as spares: GAFR300-08 filter & regulator, GAL300-08 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.

Size Class & Flow Envelope

  • GAFC2001/8"-1/4" · 1750 L/min
  • GAFC3001/4"-1/2" · 3500 L/min
  • GAFC4003/8"-1/2" · 6000 L/min
  • GAFC5003/4" · 7000 L/min
  • GAFC6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.

This modelGAFC300 · 1/4" · curve to 3500 L/min
One size downGAFC200
One size upGAFC400 (curve to 6000 L/min)
Build orderFilter & regulator → bracket → lubricator

Where the Airtac GAFC Air Service Unit GAFC300N08ALW Is Used

precision_manufacturing

Precision Fixture Clamping

Feed a small work-holding fixture on a benchtop assembly station, where the 1/4in port and lower pressure range protect delicate parts from over-clamping.

science

Laboratory Air Supply

Supply filtered, regulated air to a lab bench pneumatic actuator or test rig, with the 5 um element keeping fine particles away from sensitive valves.

packaging

Light Packaging Line

Run a single cylinder on a light packaging or labeling machine, where the automatic drain reduces maintenance on a line that runs intermittently.

Is the Airtac GAFC Air Service Unit GAFC300N08ALW the Right Air-Prep Unit?

Choose the GAFC300N08ALW when your circuit needs a modest 1/4in port with a lower regulated ceiling of 0.4 MPa. The nylon bowl is specified by the N code, and the automatic drain suits lines where condensate builds up between visits. The 5 um element traps finer particles than the standard 40 um grade, though it will need more frequent service. The default PT thread carries an MPa/psi gauge scale, and the K option adds a reverse-flow valve if you need it. Spare parts are the GAFR300-08 filter-regulator and the GAL300-08 lubricator, both orderable separately. With a 1.0 MPa max supply, you have about 0.6 MPa of headroom above the 0.4 MPa top of the regulated range.

Quick checklist

  • ✓ Body size for your peak flow (1/4" here)
  • ✓ Standard 0.9 MPa or lower-pressure 0.4 MPa
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Element 40 µm or 5 µm
  • ✓ Thread & gauge scale (PT / G / NPT)
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter-regulator first, lubricator last.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Fill the oil bowl with ISO VG 32 or equivalent only.
  • check Drain condensate before the 60 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 1020 g unit on its bracket, not on the tubing.

The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR300-08 filter-regulator on that branch instead of the full combination.

Airtac GAFC Air Service Unit GAFC300N08ALW FAQ

This F.R.L. combination operates at 0.15-0.4 MPa (20-58 psi) with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). It works in -5 to 70 C temperatures, uses ISO VG 32 lubricant, has a 60 cc drain bowl and 98 cc oil bowl, and weighs 1020 g.

The L code specifies the lower-pressure type, which tops out at 0.4 MPa instead of the standard 0.9 MPa. This suits applications needing gentle, consistent pressure below 0.4 MPa. If your machine may ever require more than 0.4 MPa, choose the standard S type instead, as this unit cannot be adjusted beyond its rated ceiling.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GAFC Air Service Unit GAFC300N08ALW

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for GAFC300N08ALW and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.