The AirTAC Airtac GAFC Air Service Unit GAFC300N08ALWK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/4" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
This AirTAC GAFC300N08ALWK is an F.R.L. combination that pairs a filter-regulator with a lubricator on a single T-bracket, so the air is cleaned, set to pressure, and then oil-misted in one compact two-piece assembly. The 1/4in port and 1020 g mass place it in the GAFC300 size class, which suits small machine stations and single actuator feeds.
The lower-pressure regulator is set for 0.15-0.4 MPa (20-58 psi), with a 5 um element trapping fine particles before the air reaches the lubricator. The nylon bowl holds 60 cc of condensate and the oil bowl 98 cc, and the automatic drain clears water without an operator, making this a low-attention unit for a wet or remote line.
| Model | Airtac GAFC Air Service Unit GAFC300N08ALWK |
|---|---|
| Series | GAFC300 F.R.L. combination |
| Port size | 1/4" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Nylon |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1020 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.
| GAFC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 08 | Port size 1/4". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAFR300-08 filter & regulator, GAL300-08 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC300 · 1/4" · curve to 3500 L/min |
|---|---|
| One size down | GAFC200 |
| One size up | GAFC400 (curve to 6000 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Feed a 5 um-filtered, regulated air supply to a precision pneumatic valve on a small assembly station, where the lower 0.4 MPa range prevents over-pressuring delicate actuators.
Mount on a machine header in a humid plant where the automatic drain clears water from the 60 cc bowl without an operator, keeping a single shift running unattended.
Power a bench-mounted jig or clamping fixture with a 1/4in line, using the 98 cc oil bowl to lubricate the cylinder while the 5 um element protects its seals.
Choose the 1/4in port for a small jig or a single cylinder; step up to the GAFC400's 3/8in port and 100 cc bowl if the line feeds several actuators. The nylon bowl is a build choice, not a performance upgrade - the 1.0 MPa max and -5 to 70 C rating are the same for PC, metal, or nylon, so confirm the material suits your environment. The automatic drain handles condensate on its own, while the 5 um element catches finer particles than the standard 40 um, at the cost of more frequent element changes. The fitted circular gauge reads in MPa and psi on the PT thread, and the reverse-flow valve is present as an ordering option. Spares are GAFR300-08 and GAL300-08, both orderable separately. With a 1.0 MPa max supply, you have about 0.6 MPa of headroom above this unit's 0.4 MPa top setting, so plan the inlet pressure accordingly.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR300-08 filter-regulator on that branch instead of the full combination.
The GAFC300N08ALWK operates at 0.15-0.4 MPa (20-58 psi) with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). It has a 60 cc drain bowl and a 98 cc oil bowl, weighs 1020 g, and is rated for -5 to 70 C. The recommended lubricant is ISO VG 32, and the 5 um element filters the air before it reaches the lubricator.
The L type code sets the regulator to 0.15-0.4 MPa instead of the standard 0.15-0.9 MPa, which suits applications that need a gentle, consistent supply without the risk of over-pressurization. If your machine may ever require more than 0.4 MPa, this is the wrong part - choose the S type instead. The 1.0 MPa max supply gives about 0.6 MPa of headroom above the 0.4 MPa top setting.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.