The AirTAC Airtac GAFC Air Service Unit GAFC300N08ASNW is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/4" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
This AirTAC GAFC300N08ASNW is a two-piece F.R.L. combination: a filter-regulator body paired with a lubricator, mounted on a T-bracket with quick clamps. The 1/4in port and 1020 g mass place it in the mid-size class, suited for a single machine station or a small pneumatic circuit.
The filter removes solids and water, the regulator holds the set pressure, and the lubricator adds a metered oil mist last, so oil never travels back through the regulator seat. It operates from 0.15 to 0.9 MPa (20-130 psi) with a 5 um element, and the nylon bowl is a build choice - confirm it suits your environment, as the -5 to 70 C rating is shared across all bowl materials.
| Model | Airtac GAFC Air Service Unit GAFC300N08ASNW |
|---|---|
| Series | GAFC300 F.R.L. combination |
| Port size | 1/4" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Nylon |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1020 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFC300 is 1/8" if you add one.
| GAFC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 08 | Port size 1/4". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAFR300-08 filter & regulator, GAL300-08 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC300 · 1/4" · curve to 3500 L/min |
|---|---|
| One size down | GAFC200 |
| One size up | GAFC400 (curve to 6000 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Feed a 5 um-filtered, regulated air supply to a precision pneumatic valve on a CNC tool changer, where fine particles could cause sticking.
Power a dedicated clamping fixture on an assembly bench, with the automatic drain handling condensate from a humid plant line.
Supply clean, pressure-set air to a leak-test fixture, where the 5 um element protects sensitive gauges and the lubricator oils the test cylinder.
Choose this GAFC300N08ASNW when you need a 1/4in port with a 5 um element for finer filtration, and an automatic drain that clears condensate without an operator. The nylon bowl is specified by the N before the port code; the gauge is omitted (N after the port), so the 1/8in gauge connection is available if you add one later. The PT thread carries an MPa/psi scale if a gauge is fitted. For oil-free lines, omit the lubricator and select a plain GAFR300-08 filter-regulator instead; spares for this unit are GAFR300-08 and GAL300-08.
Max supply of 1.0 MPa leaves about 0.1 MPa above the 0.9 MPa top of the regulated range, so plan the inlet pressure accordingly if you need the full band.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR300-08 filter-regulator on that branch instead of the full combination.
This F.R.L. combination works from 0.15 to 0.9 MPa (20-130 psi), with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). It operates from -5 to 70 C, uses ISO VG 32 lubricant, has a 60 cc drain bowl and 98 cc oil bowl, and weighs 1020 g. The 5 um element and automatic drain are fitted.
The N after the port code means no gauge is supplied. The GAFC300 body has a 1/8in gauge connection, so you can add a circular gauge later if you need to read the set pressure directly. The PT thread option uses an MPa/psi scale.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.