AirTAC GAFC300 · F.R.L. Combination (Filter-Regulator + Lubricator)

Airtac GAFC Air Service Unit GAFC300N08ASNW

The AirTAC Airtac GAFC Air Service Unit GAFC300N08ASNW is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/4" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination
  • Port size1/4"
  • Pressure range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • Bowl materialNylon
  • Drainautomatic
  • Pressure gaugeNot fitted
  • Weight1020 g
$78.74 $87.75Save 10% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GAFC Air Service Unit GAFC300N08ASNW

This AirTAC GAFC300N08ASNW is a two-piece F.R.L. combination: a filter-regulator body paired with a lubricator, mounted on a T-bracket with quick clamps. The 1/4in port and 1020 g mass place it in the mid-size class, suited for a single machine station or a small pneumatic circuit.

The filter removes solids and water, the regulator holds the set pressure, and the lubricator adds a metered oil mist last, so oil never travels back through the regulator seat. It operates from 0.15 to 0.9 MPa (20-130 psi) with a 5 um element, and the nylon bowl is a build choice - confirm it suits your environment, as the -5 to 70 C rating is shared across all bowl materials.

Airtac GAFC Air Service Unit GAFC300N08ASNW Technical Specifications

ModelAirtac GAFC Air Service Unit GAFC300N08ASNW
SeriesGAFC300 F.R.L. combination
Port size1/4" (PT thread)
Filtering grade5 µm
Pressure range0.15 - 0.9 MPa (20 - 130 psi)
TypeStandard
Bowl materialNylon
Drain typeAutomatic drain
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl60 cc
Capacity of oil bowl98 cc
Recommended lubricantISO VG 32 or equivalent
Weight1020 g

Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFC300 is 1/8" if you add one.

Model Code: Airtac GAFC Air Service Unit GAFC300N08ASNW

GAFC300GA300 series F.R.L. unit — sets ports, bowl capacity and weight.
NBowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N).
08Port size 1/4". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2".
ADrain: Automatic drain.
SStandard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L).
NNo pressure gauge; 1/8" gauge connection.
WFiltering grade 5 µm.
(blank)PT thread; gauge scale MPa / psi.
(blank)No reverse-flow valve.

Constituent units, orderable separately as spares: GAFR300-08 filter & regulator, GAL300-08 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.

Size Class & Flow Envelope

  • GAFC2001/8"-1/4" · 1750 L/min
  • GAFC3001/4"-1/2" · 3500 L/min
  • GAFC4003/8"-1/2" · 6000 L/min
  • GAFC5003/4" · 7000 L/min
  • GAFC6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.

This modelGAFC300 · 1/4" · curve to 3500 L/min
One size downGAFC200
One size upGAFC400 (curve to 6000 L/min)
Build orderFilter & regulator → bracket → lubricator

Where the Airtac GAFC Air Service Unit GAFC300N08ASNW Is Used

precision_manufacturing

Precision valve control

Feed a 5 um-filtered, regulated air supply to a precision pneumatic valve on a CNC tool changer, where fine particles could cause sticking.

factory

Single-station assembly

Power a dedicated clamping fixture on an assembly bench, with the automatic drain handling condensate from a humid plant line.

engineering

Test rig air prep

Supply clean, pressure-set air to a leak-test fixture, where the 5 um element protects sensitive gauges and the lubricator oils the test cylinder.

Is the Airtac GAFC Air Service Unit GAFC300N08ASNW the Right Air-Prep Unit?

Choose this GAFC300N08ASNW when you need a 1/4in port with a 5 um element for finer filtration, and an automatic drain that clears condensate without an operator. The nylon bowl is specified by the N before the port code; the gauge is omitted (N after the port), so the 1/8in gauge connection is available if you add one later. The PT thread carries an MPa/psi scale if a gauge is fitted. For oil-free lines, omit the lubricator and select a plain GAFR300-08 filter-regulator instead; spares for this unit are GAFR300-08 and GAL300-08.

Max supply of 1.0 MPa leaves about 0.1 MPa above the 0.9 MPa top of the regulated range, so plan the inlet pressure accordingly if you need the full band.

Quick checklist

  • ✓ Body size for your peak flow (1/4" here)
  • ✓ Standard 0.9 MPa or lower-pressure 0.4 MPa
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Element 40 µm or 5 µm
  • ✓ Thread & gauge scale (PT / G / NPT)
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter-regulator first, lubricator last.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Fill the oil bowl with ISO VG 32 or equivalent only.
  • check Drain condensate before the 60 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 1020 g unit on its bracket, not on the tubing.

The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR300-08 filter-regulator on that branch instead of the full combination.

Airtac GAFC Air Service Unit GAFC300N08ASNW FAQ

This F.R.L. combination works from 0.15 to 0.9 MPa (20-130 psi), with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). It operates from -5 to 70 C, uses ISO VG 32 lubricant, has a 60 cc drain bowl and 98 cc oil bowl, and weighs 1020 g. The 5 um element and automatic drain are fitted.

The N after the port code means no gauge is supplied. The GAFC300 body has a 1/8in gauge connection, so you can add a circular gauge later if you need to read the set pressure directly. The PT thread option uses an MPa/psi scale.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GAFC Air Service Unit GAFC300N08ASNW

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for GAFC300N08ASNW and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.