The AirTAC Airtac GAFC Air Service Unit GAFC300N08ASW is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/4" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
This AirTAC GAFC300N08ASW is a two-piece F.R.L. combination: the filter and regulator share one body, and the lubricator mounts on a T-bracket beside it. With a 1/4in port, it handles the 0.15-0.9 MPa (20-130 psi) range and uses a 5 um element to catch fine particles before they reach sensitive valves.
The nylon bowl holds 60 cc of condensate while the oil bowl holds 98 cc, and the automatic drain clears water without an operator. The circular gauge reads in MPa/psi, and the whole unit weighs 1020 g, so it needs a proper panel mount rather than tubing support.
| Model | Airtac GAFC Air Service Unit GAFC300N08ASW |
|---|---|
| Series | GAFC300 F.R.L. combination |
| Port size | 1/4" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Nylon |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1020 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.
| GAFC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 08 | Port size 1/4". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAFR300-08 filter & regulator, GAL300-08 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC300 · 1/4" · curve to 3500 L/min |
|---|---|
| One size down | GAFC200 |
| One size up | GAFC400 (curve to 6000 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
The 5 um element protects small solenoid valves on a pick-and-place arm from fine abrasive dust, while the regulator holds the set pressure for consistent actuator speed.
On a carton erector with a 1/4in air circuit, this unit filters and lubricates the cylinders that drive folding rails, with the automatic drain handling condensate from humid plant air.
For a small drill press needing clean, regulated air and a metered oil mist for its pneumatic feed cylinder, this combination delivers both functions in a compact two-piece footprint.
Choose the GAFC300N08ASW when you need 1/4in ports with the finer 5 um element and an automatic drain for unattended lines. The nylon bowl is a build choice, not a performance upgrade - the 1.0 MPa max and -5 to 70 C rating stay the same across materials, so confirm it suits your environment. The PT thread carries a gauge with an MPa/psi scale, and you can order the filter-regulator and lubricator separately as GAFR300-08 and GAL300-08 if a bowl or element needs replacement.
With a 1.0 MPa max supply, you have about 0.1 MPa of headroom above the 0.9 MPa top of the regulated range, so plan your inlet pressure carefully if you need the full output.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR300-08 filter-regulator on that branch instead of the full combination.
It operates at 0.15-0.9 MPa (20-130 psi) with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). The temperature range is -5 to 70 C, and it uses ISO VG 32 lubricant. The drain bowl holds 60 cc, the oil bowl holds 98 cc, and the unit weighs 1020 g.
The W code specifies a 5 um element, which traps finer particles than the standard 40 um grade. This suits precision valves or instrument air circuits, but the finer element will load up faster and need more frequent service, so factor that into your maintenance schedule.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.