AirTAC GAFC300 · F.R.L. Combination (Filter-Regulator + Lubricator)

Airtac GAFC Air Service Unit GAFC300N08LN

The AirTAC Airtac GAFC Air Service Unit GAFC300N08LN is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/4" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).

  • TypeF.R.L. combination
  • Port size1/4"
  • Pressure range0.15 - 0.4 MPa (20 - 58 psi)
  • Filtering grade40 µm
  • Bowl materialNylon
  • Drainsemi-auto + manual
  • Pressure gaugeNot fitted
  • Weight1020 g
$70.03 $78.44Save 10% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GAFC Air Service Unit GAFC300N08LN

This AirTAC GAFC300N08LN is a two-piece F.R.L. combination: a filter-regulator body handles filtration and pressure control, then the lubricator adds a metered oil mist downstream. With a 1/4in port and a 1020 g mass, it suits compact machine builds where panel space is at a premium.

The lower-pressure type regulates from 0.15 to 0.4 MPa (20-58 psi), and the nylon bowl holds 60 cc of condensate while the oil bowl holds 98 cc. The 40 um element traps standard workshop particles. No gauge is supplied, so the 1/8in gauge connection must be used if a readout is added later.

Airtac GAFC Air Service Unit GAFC300N08LN Technical Specifications

ModelAirtac GAFC Air Service Unit GAFC300N08LN
SeriesGAFC300 F.R.L. combination
Port size1/4" (PT thread)
Filtering grade40 µm
Pressure range0.15 - 0.4 MPa (20 - 58 psi)
TypeLower pressure
Bowl materialNylon
Drain typeSemi-auto drain + manual drain
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl60 cc
Capacity of oil bowl98 cc
Recommended lubricantISO VG 32 or equivalent
Weight1020 g

Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFC300 is 1/8" if you add one.

Model Code: Airtac GAFC Air Service Unit GAFC300N08LN

GAFC300GA300 series F.R.L. unit — sets ports, bowl capacity and weight.
NBowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N).
08Port size 1/4". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2".
(blank)Drain: Semi-auto drain + manual drain.
LLower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L).
NNo pressure gauge; 1/8" gauge connection.
(blank)Filtering grade 40 µm.
(blank)PT thread; gauge scale MPa / psi.
(blank)No reverse-flow valve.

Constituent units, orderable separately as spares: GAFR300-08 filter & regulator, GAL300-08 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.

Size Class & Flow Envelope

  • GAFC2001/8"-1/4" · 1750 L/min
  • GAFC3001/4"-1/2" · 3500 L/min
  • GAFC4003/8"-1/2" · 6000 L/min
  • GAFC5003/4" · 7000 L/min
  • GAFC6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.

This modelGAFC300 · 1/4" · curve to 3500 L/min
One size downGAFC200
One size upGAFC400 (curve to 6000 L/min)
Build orderFilter & regulator → bracket → lubricator

Where the Airtac GAFC Air Service Unit GAFC300N08LN Is Used

precision_manufacturing

Precision Fixture Clamping

Feed a single pneumatic clamp on a benchtop assembly fixture. The lower-pressure range protects delicate workpieces from over-force while the lubricator keeps the clamp cylinder cycling smoothly.

science

Lab Air Bench

Supply a small laboratory test rig that needs regulated air below 0.4 MPa. The 60 cc condensate bowl handles moisture from a humid compressor line, and the nylon bowl resists incidental lab splashes.

handyman

Paint Spray Booth

Run a single airbrush or small spray gun at a controlled low pressure. The 98 cc oil bowl delivers consistent mist for the tool's internal lubricator, and the 1/4in port matches common spray equipment.

Is the Airtac GAFC Air Service Unit GAFC300N08LN the Right Air-Prep Unit?

Choose the GAFC300N08LN when your circuit needs a 1/4in port and a regulated ceiling of 0.4 MPa (20-58 psi). The nylon bowl is a material choice that does not change the shared 1.0 MPa (145 psi) maximum pressure or the -5 to 70 C temperature range, so confirm it suits your environment. The semi-auto drain dumps condensate on pressure drop, with a manual override for on-demand draining, and the 40 um element is the standard grade. The PT thread carries an MPa/psi gauge scale if you fit a gauge later. Orderable spares are the GAFR300-08 filter-regulator and the GAL300-08 lubricator. The 1.0 MPa max supply leaves about 0.6 MPa above the 0.4 MPa top of the range, so plan your inlet pressure accordingly.

Quick checklist

  • ✓ Body size for your peak flow (1/4" here)
  • ✓ Standard 0.9 MPa or lower-pressure 0.4 MPa
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Element 40 µm or 5 µm
  • ✓ Thread & gauge scale (PT / G / NPT)
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter-regulator first, lubricator last.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Fill the oil bowl with ISO VG 32 or equivalent only.
  • check Drain condensate before the 60 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 1020 g unit on its bracket, not on the tubing.

The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR300-08 filter-regulator on that branch instead of the full combination.

Airtac GAFC Air Service Unit GAFC300N08LN FAQ

This lower-pressure F.R.L. combination works from 0.15 to 0.4 MPa (20-58 psi), with a 1.0 MPa (145 psi) maximum and 1.5 MPa (215 psi) proof pressure. The temperature range is -5 to 70 C, and the recommended lubricant is ISO VG 32. It has a 60 cc condensate bowl, a 98 cc oil bowl, and weighs 1020 g. The 40 um element handles standard filtration, and the PT thread is standard.

The N after the port code means no gauge is supplied with this unit. The GAFC300 body has a 1/8in gauge connection, so you can add a compatible pressure gauge if you need to read the setpoint. Without one, you cannot verify the regulated pressure visually, so plan to fit a gauge for applications where the exact pressure matters.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GAFC Air Service Unit GAFC300N08LN

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for GAFC300N08LN and will confirm price, stock and lead time — usually within 7-8 hours.