The AirTAC Airtac GAFC Air Service Unit GAFC300N08LW is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/4" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
This AirTAC GAFC300N08LW is a two-piece F.R.L. combination: a filter-regulator body paired with a lubricator on a shared T-bracket. With a 1/4in port, it handles 0.15-0.4 MPa (20-58 psi) and uses a 5 um element to catch fine particles before air reaches the lubricator.
The nylon bowl holds 60 cc of condensate and the oil bowl 98 cc, giving a 1020 g unit that suits panel mounting. The circular gauge reads in MPa and psi, while the semi-auto drain dumps condensate on pressure drops and the manual drain works on demand. Oil mist is added last, downstream of the regulator seat.
| Model | Airtac GAFC Air Service Unit GAFC300N08LW |
|---|---|
| Series | GAFC300 F.R.L. combination |
| Port size | 1/4" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Nylon |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1020 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.
| GAFC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 08 | Port size 1/4". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAFR300-08 filter & regulator, GAL300-08 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC300 · 1/4" · curve to 3500 L/min |
|---|---|
| One size down | GAFC200 |
| One size up | GAFC400 (curve to 6000 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Feed a 5 um-filtered, lower-pressure air supply to a CNC spindle air curtain or bearing pressurization line, where fine particle control matters and regulated pressure stays below 0.4 MPa.
Supply instrument air to a lab bench pneumatic actuator or valve manifold, using the 5 um element to protect sensitive components and the lower pressure range for delicate operations.
Run a small pick-and-place gripper or a single-axis slide on a 1/4in line, where the 60 cc condensate bowl and 98 cc oil bowl reduce service frequency on a compact machine station.
Choose the GAFC300N08LW when your line needs lower regulated pressure up to 0.4 MPa and finer 5 um filtration. The nylon bowl is a build choice; the common specification of 1.0 MPa max and -5 to 70 C applies regardless, so confirm nylon suits your environment. The semi-auto plus manual drain pair covers both automatic dumping and operator-controlled draining.
For a standard 0.15-0.9 MPa range, step to the GAFC30008AS; for a 3/8in port, pick the GAFC30010LW. The GAFR300-08 filter-regulator and GAL300-08 lubricator are orderable separately. With a 1.0 MPa max supply, you have about 0.6 MPa above the 0.4 MPa top of the regulated band.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR300-08 filter-regulator on that branch instead of the full combination.
The GAFC300N08LW operates at 0.15-0.4 MPa (20-58 psi) with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). Temperature range is -5 to 70 C. It has a 60 cc drain bowl and 98 cc oil bowl, weighs 1020 g, and uses ISO VG 32 lubricant. The 5 um element filters air before the lubricator adds oil mist.
The L in the code specifies a lower regulated band of 0.15-0.4 MPa, suited for applications that never need more than 0.4 MPa. The W specifies a 5 um element, which traps finer particles than the standard 40 um for precision equipment. The trade-off is that the 5 um element needs more frequent service, and the lower range caps your maximum regulated pressure.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.