AirTAC GAFC300 · F.R.L. Combination (Filter-Regulator + Lubricator)

Airtac GAFC Air Service Unit GAFC300N08SK

The AirTAC Airtac GAFC Air Service Unit GAFC300N08SK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/4" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination
  • Port size1/4"
  • Pressure range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • Bowl materialNylon
  • Drainsemi-auto + manual
  • Pressure gaugeCircular, MPa / psi
  • Weight1020 g
$86.35 $95.87Save 9% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GAFC Air Service Unit GAFC300N08SK

The GAFC300N08SK is a two-piece F.R.L. combination built for a 1/4in line. The first body houses both the filter and the regulator, so air is cleaned and set to pressure in one step before passing to the lubricator, which adds a metered oil mist last. This order keeps oil away from the regulator seat, a design consequence of the shared body.

This unit regulates from 0.15 to 0.9 MPa (20-130 psi) with a 40 um element. The nylon bowl holds 60 cc of condensate, while the oil bowl holds 98 cc. At 1020 g, it needs a proper panel or frame mount rather than support from the tubing. The circular gauge is fitted and reads in MPa and psi.

Airtac GAFC Air Service Unit GAFC300N08SK Technical Specifications

ModelAirtac GAFC Air Service Unit GAFC300N08SK
SeriesGAFC300 F.R.L. combination
Port size1/4" (PT thread)
Filtering grade40 µm
Pressure range0.15 - 0.9 MPa (20 - 130 psi)
TypeStandard
Bowl materialNylon
Drain typeSemi-auto drain + manual drain
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl60 cc
Capacity of oil bowl98 cc
Recommended lubricantISO VG 32 or equivalent
Weight1020 g

Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.

Model Code: Airtac GAFC Air Service Unit GAFC300N08SK

GAFC300GA300 series F.R.L. unit — sets ports, bowl capacity and weight.
NBowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N).
08Port size 1/4". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2".
(blank)Drain: Semi-auto drain + manual drain.
SStandard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L).
(blank)Circular pressure gauge fitted.
(blank)Filtering grade 40 µm.
(blank)PT thread; gauge scale MPa / psi.
KReverse-flow (reflux) valve attached.

Constituent units, orderable separately as spares: GAFR300-08 filter & regulator, GAL300-08 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.

Size Class & Flow Envelope

  • GAFC2001/8"-1/4" · 1750 L/min
  • GAFC3001/4"-1/2" · 3500 L/min
  • GAFC4003/8"-1/2" · 6000 L/min
  • GAFC5003/4" · 7000 L/min
  • GAFC6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.

This modelGAFC300 · 1/4" · curve to 3500 L/min
One size downGAFC200
One size upGAFC400 (curve to 6000 L/min)
Build orderFilter & regulator → bracket → lubricator

Where the Airtac GAFC Air Service Unit GAFC300N08SK Is Used

precision_manufacturing

Precision Jig Cylinders

Feed a single 1/4in-actuated jig or clamp cylinder on an assembly bench. The 40 um element protects the valve, while the lubricator keeps the cylinder seal moving.

conveyor_belt

Short Conveyor Sections

Supply a short belt conveyor's tensioning cylinder with filtered, regulated air and a fine oil mist. The 60 cc drain bowl suits intermittent operation with regular checks.

engineering

Test Bench Air Supply

Run a small test fixture that needs clean air at a set pressure. The gauge lets the operator dial in the exact setting, and the lubricator protects downstream tooling.

Is the Airtac GAFC Air Service Unit GAFC300N08SK the Right Air-Prep Unit?

Choose the GAFC300N08SK when a 1/4in port suits the flow demand and the line needs both filtration and lubrication. The nylon bowl is a build choice; the catalogue gives no impact or chemical data, so confirm it suits the surroundings. This model ships with both a semi-auto drain, which dumps on pressure drop, and a manual drain for on-demand use. The reverse-flow valve is fitted, shown as a separate symbol in the catalogue. Spare parts are orderable as the GAFR300-08 filter-regulator and the GAL300-08 lubricator, so a worn element does not force a full replacement. With a 1.0 MPa max supply, there is only about 0.1 MPa of headroom above the 0.9 MPa top of the regulated range, so plan the supply pressure accordingly.

Quick checklist

  • ✓ Body size for your peak flow (1/4" here)
  • ✓ Standard 0.9 MPa or lower-pressure 0.4 MPa
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Element 40 µm or 5 µm
  • ✓ Thread & gauge scale (PT / G / NPT)
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter-regulator first, lubricator last.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Fill the oil bowl with ISO VG 32 or equivalent only.
  • check Drain condensate before the 60 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 1020 g unit on its bracket, not on the tubing.

The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR300-08 filter-regulator on that branch instead of the full combination.

Airtac GAFC Air Service Unit GAFC300N08SK FAQ

The GAFC300N08SK works with air only, filtering to 40 um. The standard pressure range is 0.15-0.9 MPa (20-130 psi), with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). Operating temperature is -5 to 70 C. The drain bowl holds 60 cc and the oil bowl 98 cc. Use ISO VG 32 lubricant. The unit weighs 1020 g.

The K indicates the reverse-flow (reflux) valve is fitted. This is a factory-installed option that appears as a separate pneumatic symbol in the catalogue. It is part of the ordering code, so the unit arrives with the valve already in place.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GAFC Air Service Unit GAFC300N08SK

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for GAFC300N08SK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.