The AirTAC Airtac GAFC Air Service Unit GAFC300N10ALW is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 3/8" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
This AirTAC GAFC300N10ALW is a two-piece F.R.L. combination: a filter-regulator body paired with a separate lubricator, mounted on a shared T-bracket with quick clamps. The 3/8in port size and 1020 g mass place it in the mid-range GAFC300 class, suited for a single machine station or a small pneumatic circuit.
Air enters the first body where the 5 um element traps fine particles and the lower-pressure regulator sets output between 0.15-0.4 MPa (20-58 psi). The lubricator then adds a metered ISO VG 32 oil mist downstream, so oil never travels back through the regulator seat. The nylon bowl holds 60 cc of condensate while the oil bowl holds 98 cc, and the automatic drain clears water without an operator.
| Model | Airtac GAFC Air Service Unit GAFC300N10ALW |
|---|---|
| Series | GAFC300 F.R.L. combination |
| Port size | 3/8" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Nylon |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1020 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.
| GAFC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAFR300-10 filter & regulator, GAL300-10 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC300 · 3/8" · curve to 3500 L/min |
|---|---|
| One size down | GAFC200 |
| One size up | GAFC400 (curve to 6000 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Feed a compact pneumatic press or a precision tightening tool on an assembly bench, where the 5 um element protects sensitive valves and the lower pressure range suits delicate operations.
Supply filtered, regulated air to a lab fixture or test jig that operates below 0.4 MPa, where the automatic drain keeps condensate out of the instrument air without daily attention.
Run a single air cylinder or a small indexing mechanism on a packaging line, where the 3/8in port matches short runs and the 1020 g unit mounts easily on a machine frame.
The GAFC300N10ALW combines a nylon bowl, automatic drain, lower-pressure regulation, and a 5 um element on a 3/8in port. The L-type regulator tops out at 0.4 MPa (20-58 psi), so if your machine may ever need more than that, step to the standard S type instead. The nylon bowl is a build choice; the shared specification of 1.0 MPa max and -5 to 70 C applies equally to PC and metal bowls, so confirm the material suits your environment. The circular gauge reads in MPa/psi for the default PT thread, and the 5 um element catches finer particles than the standard 40 um but will need more frequent service. For oil-free lines, omit the lubricator and choose a plain GAFR300-10 filter-regulator. Spare parts are orderable separately as GAFR300-10 and GAL300-10. With a 1.0 MPa max supply, you have about 0.6 MPa of headroom above the 0.4 MPa top of this unit's regulated range.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR300-10 filter-regulator on that branch instead of the full combination.
This F.R.L. combination operates at 0.15-0.4 MPa (20-58 psi) with a maximum pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). The temperature range is -5 to 70 C, and the recommended lubricant is ISO VG 32. The drain bowl holds 60 cc, the oil bowl holds 98 cc, and the unit weighs 1020 g. The 5 um element and automatic drain are fitted, and the circular gauge reads in MPa/psi.
The L in the code specifies the lower-pressure regulator type, which tops out at 0.4 MPa (20-58 psi) instead of the standard 0.9 MPa. This suits applications that never need higher pressure, such as delicate gripping or light clamping. If your process may require more pressure later, the standard S type would be the safer choice.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.