The AirTAC Airtac GAFC Air Service Unit GAFC300N10L is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 3/8" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
The GAFC300N10L is a two-piece F.R.L. combination: a filter-regulator body paired with a lubricator on a shared T-bracket. Air enters the 3/8" port, gets filtered and set to pressure in the first body, then the lubricator adds a metered oil mist downstream. This lower-pressure version regulates from 0.15 to 0.4 MPa (20-58 psi), with a 40 um element catching solids and moisture.
The nylon bowl holds 60 cc of condensate and the oil bowl 98 cc, giving this 1020 g unit a practical service rhythm for medium-duty lines. The circular gauge reads in MPa/psi, and the semi-auto drain dumps on pressure drop while the manual drain works on demand. With a 1.0 MPa max supply, there is about 0.6 MPa of headroom above the 0.4 MPa top of the range.
| Model | Airtac GAFC Air Service Unit GAFC300N10L |
|---|---|
| Series | GAFC300 F.R.L. combination |
| Port size | 3/8" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Nylon |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1020 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.
| GAFC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAFR300-10 filter & regulator, GAL300-10 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC300 · 3/8" · curve to 3500 L/min |
|---|---|
| One size down | GAFC200 |
| One size up | GAFC400 (curve to 6000 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Feed a delicate press-fit or insertion station that runs at 0.3 MPa to avoid damaging small components. The 0.15-0.4 MPa band gives fine control for force-sensitive operations.
Supply filtered, regulated air to a lab bench with pneumatic actuators or valves that must stay below 0.4 MPa. The 40 um element and lubricator keep moving parts working smoothly.
Regulate atomizing air for low-pressure spray equipment where exceeding 0.4 MPa would over-atomize the coating. The 60 cc drain bowl handles moisture from wet supply lines.
Choose the GAFC300N10L when your circuit needs regulated air below 0.4 MPa (58 psi) and a 3/8" port fits the flow. The nylon bowl is a build choice - confirm it suits your environment, as the catalogue gives no material-specific ratings. The semi-auto drain clears condensate on each pressure drop, with a manual backup for scheduled maintenance. The 40 um element handles general shop air; step to the W option for 5 um filtration if you feed precision valves. The PT thread carries a MPa/psi gauge scale, so operators read the same units as the fittings. If the line must stay oil-free, omit the lubricator and choose a plain GAFR300-10 filter-regulator instead. Spares are the GAFR300-10 and GAL300-10, both orderable separately. The 1.0 MPa max supply leaves about 0.6 MPa above the 0.4 MPa top of the regulated range.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR300-10 filter-regulator on that branch instead of the full combination.
The GAFC300N10L operates from 0.15 to 0.4 MPa (20-58 psi) with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). Temperature range is -5 to 70 C. It has a 60 cc drain bowl and 98 cc oil bowl, weighs 1020 g, and uses ISO VG 32 lubricant. The element grade is 40 um.
The L code sets the regulation ceiling at 0.4 MPa instead of the standard 0.9 MPa. This suits circuits that must never exceed 0.4 MPa, such as delicate gripping or low-force positioning. If your machine might need more pressure later, the standard S type would be the safer choice.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.