verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GAFC300 · F.R.L. Combination (Filter-Regulator + Lubricator)

Airtac GAFC Air Service Unit GAFC300N10L

The AirTAC Airtac GAFC Air Service Unit GAFC300N10L is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 3/8" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).

  • TypeF.R.L. combination
  • Port size3/8"
  • Pressure range0.15 - 0.4 MPa (20 - 58 psi)
  • Filtering grade40 µm
  • Bowl materialNylon
  • Drainsemi-auto + manual
  • Pressure gaugeCircular, MPa / psi
  • Weight1020 g
$75.45 $84.23Save 10% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GAFC Air Service Unit GAFC300N10L

The GAFC300N10L is a two-piece F.R.L. combination: a filter-regulator body paired with a lubricator on a shared T-bracket. Air enters the 3/8" port, gets filtered and set to pressure in the first body, then the lubricator adds a metered oil mist downstream. This lower-pressure version regulates from 0.15 to 0.4 MPa (20-58 psi), with a 40 um element catching solids and moisture.

The nylon bowl holds 60 cc of condensate and the oil bowl 98 cc, giving this 1020 g unit a practical service rhythm for medium-duty lines. The circular gauge reads in MPa/psi, and the semi-auto drain dumps on pressure drop while the manual drain works on demand. With a 1.0 MPa max supply, there is about 0.6 MPa of headroom above the 0.4 MPa top of the range.

Airtac GAFC Air Service Unit GAFC300N10L Technical Specifications

ModelAirtac GAFC Air Service Unit GAFC300N10L
SeriesGAFC300 F.R.L. combination
Port size3/8" (PT thread)
Filtering grade40 µm
Pressure range0.15 - 0.4 MPa (20 - 58 psi)
TypeLower pressure
Bowl materialNylon
Drain typeSemi-auto drain + manual drain
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl60 cc
Capacity of oil bowl98 cc
Recommended lubricantISO VG 32 or equivalent
Weight1020 g

Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.

Model Code: Airtac GAFC Air Service Unit GAFC300N10L

GAFC300GA300 series F.R.L. unit — sets ports, bowl capacity and weight.
NBowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N).
10Port size 3/8". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2".
(blank)Drain: Semi-auto drain + manual drain.
LLower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L).
(blank)Circular pressure gauge fitted.
(blank)Filtering grade 40 µm.
(blank)PT thread; gauge scale MPa / psi.
(blank)No reverse-flow valve.

Constituent units, orderable separately as spares: GAFR300-10 filter & regulator, GAL300-10 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.

Size Class & Flow Envelope

  • GAFC2001/8"-1/4" · 1750 L/min
  • GAFC3001/4"-1/2" · 3500 L/min
  • GAFC4003/8"-1/2" · 6000 L/min
  • GAFC5003/4" · 7000 L/min
  • GAFC6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.

This modelGAFC300 · 3/8" · curve to 3500 L/min
One size downGAFC200
One size upGAFC400 (curve to 6000 L/min)
Build orderFilter & regulator → bracket → lubricator

Where the Airtac GAFC Air Service Unit GAFC300N10L Is Used

precision_manufacturing

Low-Pressure Assembly Stations

Feed a delicate press-fit or insertion station that runs at 0.3 MPa to avoid damaging small components. The 0.15-0.4 MPa band gives fine control for force-sensitive operations.

science

Laboratory Air Supply

Supply filtered, regulated air to a lab bench with pneumatic actuators or valves that must stay below 0.4 MPa. The 40 um element and lubricator keep moving parts working smoothly.

engineering

Paint or Coating Lines

Regulate atomizing air for low-pressure spray equipment where exceeding 0.4 MPa would over-atomize the coating. The 60 cc drain bowl handles moisture from wet supply lines.

Is the Airtac GAFC Air Service Unit GAFC300N10L the Right Air-Prep Unit?

Choose the GAFC300N10L when your circuit needs regulated air below 0.4 MPa (58 psi) and a 3/8" port fits the flow. The nylon bowl is a build choice - confirm it suits your environment, as the catalogue gives no material-specific ratings. The semi-auto drain clears condensate on each pressure drop, with a manual backup for scheduled maintenance. The 40 um element handles general shop air; step to the W option for 5 um filtration if you feed precision valves. The PT thread carries a MPa/psi gauge scale, so operators read the same units as the fittings. If the line must stay oil-free, omit the lubricator and choose a plain GAFR300-10 filter-regulator instead. Spares are the GAFR300-10 and GAL300-10, both orderable separately. The 1.0 MPa max supply leaves about 0.6 MPa above the 0.4 MPa top of the regulated range.

Quick checklist

  • ✓ Body size for your peak flow (3/8" here)
  • ✓ Standard 0.9 MPa or lower-pressure 0.4 MPa
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Element 40 µm or 5 µm
  • ✓ Thread & gauge scale (PT / G / NPT)
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter-regulator first, lubricator last.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Fill the oil bowl with ISO VG 32 or equivalent only.
  • check Drain condensate before the 60 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 1020 g unit on its bracket, not on the tubing.

The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR300-10 filter-regulator on that branch instead of the full combination.

Airtac GAFC Air Service Unit GAFC300N10L FAQ

The GAFC300N10L operates from 0.15 to 0.4 MPa (20-58 psi) with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). Temperature range is -5 to 70 C. It has a 60 cc drain bowl and 98 cc oil bowl, weighs 1020 g, and uses ISO VG 32 lubricant. The element grade is 40 um.

The L code sets the regulation ceiling at 0.4 MPa instead of the standard 0.9 MPa. This suits circuits that must never exceed 0.4 MPa, such as delicate gripping or low-force positioning. If your machine might need more pressure later, the standard S type would be the safer choice.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GAFC Air Service Unit GAFC300N10L

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for GAFC300N10L and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.