verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GAFC300 · F.R.L. Combination (Filter-Regulator + Lubricator)

Airtac GAFC Air Service Unit GAFC300N10LK

The AirTAC Airtac GAFC Air Service Unit GAFC300N10LK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 3/8" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).

  • TypeF.R.L. combination
  • Port size3/8"
  • Pressure range0.15 - 0.4 MPa (20 - 58 psi)
  • Filtering grade40 µm
  • Bowl materialNylon
  • Drainsemi-auto + manual
  • Pressure gaugeCircular, MPa / psi
  • Weight1020 g
$86.35 $95.87Save 9% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GAFC Air Service Unit GAFC300N10LK

This AirTAC GAFC300N10LK is a two-piece F.R.L. combination where the filter and regulator share one body, paired with a lubricator on a T-bracket. It handles a 3/8in port and regulates to a lower pressure band of 0.15-0.4 MPa (20-58 psi), with a 40 um element and a nylon bowl. The 60 cc condensate bowl and 98 cc oil bowl set the service rhythm for this 1020 g unit.

The build order matters: air is cleaned and set to pressure in the first body, then the lubricator adds a metered oil mist last, so oil never travels back through the regulator seat. A circular gauge is fitted and reads in MPa/psi for the PT thread. The reverse-flow valve is fitted as a separate pneumatic symbol, and the two units are orderable as GAFR300-10 and GAL300-10.

Airtac GAFC Air Service Unit GAFC300N10LK Technical Specifications

ModelAirtac GAFC Air Service Unit GAFC300N10LK
SeriesGAFC300 F.R.L. combination
Port size3/8" (PT thread)
Filtering grade40 µm
Pressure range0.15 - 0.4 MPa (20 - 58 psi)
TypeLower pressure
Bowl materialNylon
Drain typeSemi-auto drain + manual drain
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl60 cc
Capacity of oil bowl98 cc
Recommended lubricantISO VG 32 or equivalent
Weight1020 g

Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.

Model Code: Airtac GAFC Air Service Unit GAFC300N10LK

GAFC300GA300 series F.R.L. unit — sets ports, bowl capacity and weight.
NBowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N).
10Port size 3/8". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2".
(blank)Drain: Semi-auto drain + manual drain.
LLower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L).
(blank)Circular pressure gauge fitted.
(blank)Filtering grade 40 µm.
(blank)PT thread; gauge scale MPa / psi.
KReverse-flow (reflux) valve attached.

Constituent units, orderable separately as spares: GAFR300-10 filter & regulator, GAL300-10 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.

Size Class & Flow Envelope

  • GAFC2001/8"-1/4" · 1750 L/min
  • GAFC3001/4"-1/2" · 3500 L/min
  • GAFC4003/8"-1/2" · 6000 L/min
  • GAFC5003/4" · 7000 L/min
  • GAFC6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.

This modelGAFC300 · 3/8" · curve to 3500 L/min
One size downGAFC200
One size upGAFC400 (curve to 6000 L/min)
Build orderFilter & regulator → bracket → lubricator

Where the Airtac GAFC Air Service Unit GAFC300N10LK Is Used

precision_manufacturing

Precision pressure setting

Set a delicate 0.3 MPa (43 psi) supply for a small indexing table or a light press clutch, where the lower regulation band gives finer control than a standard 0.9 MPa unit.

engineering

Compact machine build

Feed a single 3/8in actuator on a benchtop assembly fixture, using the 60 cc drain bowl to catch condensate over a shift and the 98 cc oil bowl to keep the lubricator topped up.

factory

Low-pressure test rig

Supply a leak-test station that must not exceed 0.4 MPa (58 psi), relying on the lower-pressure type to cap the output while the filter removes moisture and solids from the line.

Is the Airtac GAFC Air Service Unit GAFC300N10LK the Right Air-Prep Unit?

Choose the GAFC300N10LK when your circuit needs a 3/8in port with a lower 0.15-0.4 MPa (20-58 psi) regulation band, and you want a nylon bowl with the semi-auto plus manual drain pair. The 5 um element option (W) is not fitted here, so the standard 40 um grade is in place; step up to the GAFC400 with its 100 cc drain bowl if you need a larger reservoir and a 1/2in port. The PT thread brings an MPa/psi gauge scale, and the K code adds the reverse-flow valve to the assembly. If the line must stay oil-free, omit the lubricator and select a plain GAFR filter-regulator instead.

With a 1.0 MPa max supply, you have about 0.6 MPa of headroom above the 0.4 MPa top of the regulated range, so plan the inlet pressure accordingly.

Quick checklist

  • ✓ Body size for your peak flow (3/8" here)
  • ✓ Standard 0.9 MPa or lower-pressure 0.4 MPa
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Element 40 µm or 5 µm
  • ✓ Thread & gauge scale (PT / G / NPT)
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter-regulator first, lubricator last.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Fill the oil bowl with ISO VG 32 or equivalent only.
  • check Drain condensate before the 60 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 1020 g unit on its bracket, not on the tubing.

The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR300-10 filter-regulator on that branch instead of the full combination.

Airtac GAFC Air Service Unit GAFC300N10LK FAQ

This lower-pressure unit operates at 0.15-0.4 MPa (20-58 psi) with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). It works in -5 to 70 C temperatures, uses ISO VG 32 oil, has a 60 cc drain bowl and a 98 cc oil bowl, and weighs 1020 g. The 3/8in port and 40 um element are standard for this model.

The K indicates a reverse-flow (reflux) valve is fitted to the GAFC300N10LK. The catalogue shows it as a separate pneumatic symbol in the circuit. This is an ordering difference to note; the valve is part of the supplied assembly.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GAFC Air Service Unit GAFC300N10LK

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for GAFC300N10LK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.