verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GAFC300 · F.R.L. Combination (Filter-Regulator + Lubricator)

Airtac GAFC Air Service Unit GAFC300N10LNK

The AirTAC Airtac GAFC Air Service Unit GAFC300N10LNK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 3/8" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).

  • TypeF.R.L. combination
  • Port size3/8"
  • Pressure range0.15 - 0.4 MPa (20 - 58 psi)
  • Filtering grade40 µm
  • Bowl materialNylon
  • Drainsemi-auto + manual
  • Pressure gaugeNot fitted
  • Weight1020 g
$80.92 $90.07Save 10% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GAFC Air Service Unit GAFC300N10LNK

This GAFC300N10LNK is a two-piece F.R.L. combination: the first body houses the filter and regulator together, and the second body is the lubricator. Air enters the 3/8" port, gets filtered to 40 um, and is regulated down to the lower pressure band of 0.15-0.4 MPa (20-58 psi) before the lubricator adds a metered oil mist last.

The nylon bowl holds 60 cc of condensate and the oil bowl holds 98 cc, with the whole assembly weighing 1020 g. No gauge is supplied with this model, so the 1/8" gauge connection is available if you want to add one later. The reverse-flow (reflux) valve is fitted, and the unit is rated for -5 to 70 C with ISO VG 32 oil.

Airtac GAFC Air Service Unit GAFC300N10LNK Technical Specifications

ModelAirtac GAFC Air Service Unit GAFC300N10LNK
SeriesGAFC300 F.R.L. combination
Port size3/8" (PT thread)
Filtering grade40 µm
Pressure range0.15 - 0.4 MPa (20 - 58 psi)
TypeLower pressure
Bowl materialNylon
Drain typeSemi-auto drain + manual drain
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl60 cc
Capacity of oil bowl98 cc
Recommended lubricantISO VG 32 or equivalent
Weight1020 g

Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFC300 is 1/8" if you add one.

Model Code: Airtac GAFC Air Service Unit GAFC300N10LNK

GAFC300GA300 series F.R.L. unit — sets ports, bowl capacity and weight.
NBowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N).
10Port size 3/8". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2".
(blank)Drain: Semi-auto drain + manual drain.
LLower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L).
NNo pressure gauge; 1/8" gauge connection.
(blank)Filtering grade 40 µm.
(blank)PT thread; gauge scale MPa / psi.
KReverse-flow (reflux) valve attached.

Constituent units, orderable separately as spares: GAFR300-10 filter & regulator, GAL300-10 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.

Size Class & Flow Envelope

  • GAFC2001/8"-1/4" · 1750 L/min
  • GAFC3001/4"-1/2" · 3500 L/min
  • GAFC4003/8"-1/2" · 6000 L/min
  • GAFC5003/4" · 7000 L/min
  • GAFC6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.

This modelGAFC300 · 3/8" · curve to 3500 L/min
One size downGAFC200
One size upGAFC400 (curve to 6000 L/min)
Build orderFilter & regulator → bracket → lubricator

Where the Airtac GAFC Air Service Unit GAFC300N10LNK Is Used

precision_manufacturing

Precision pressure control

Feed a precision pneumatic regulator or a sensitive control valve that needs a stable 0.15-0.4 MPa supply, where the lower range prevents over-pressurizing delicate components.

factory

Assembly line workstations

Power a small assembly fixture or a single-axis actuator on a workbench, where the 3/8" port and 1020 g weight suit a compact machine setup without over-sizing the air prep.

science

Laboratory air supply

Supply filtered and lubricated air to a lab test rig or a small pneumatic cylinder used in experiments, where the lower pressure range protects sensitive test equipment.

Is the Airtac GAFC Air Service Unit GAFC300N10LNK the Right Air-Prep Unit?

Choose this GAFC300N10LNK when your circuit needs the lower pressure range of 0.15-0.4 MPa (20-58 psi) and you want the nylon bowl option. The semi-auto drain dumps condensate each time pressure drops, while the manual drain gives you on-demand control. Since there is no gauge fitted, plan to add one at the 1/8" connection if operators need to read the set pressure. The 40 um element handles standard shop air, and the PT thread matches common piping. The two units are separately orderable as GAFR300-10 and GAL300-10, so you can replace just the damaged section. If your line must stay oil-free, skip the lubricator and choose a plain GAFR filter-regulator instead. The 1.0 MPa max supply leaves about 0.6 MPa above the 0.4 MPa top of the range, giving you a comfortable margin for supply fluctuations.

Quick checklist

  • ✓ Body size for your peak flow (3/8" here)
  • ✓ Standard 0.9 MPa or lower-pressure 0.4 MPa
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Element 40 µm or 5 µm
  • ✓ Thread & gauge scale (PT / G / NPT)
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter-regulator first, lubricator last.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Fill the oil bowl with ISO VG 32 or equivalent only.
  • check Drain condensate before the 60 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 1020 g unit on its bracket, not on the tubing.

The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR300-10 filter-regulator on that branch instead of the full combination.

Airtac GAFC Air Service Unit GAFC300N10LNK FAQ

The GAFC300N10LNK operates at 0.15-0.4 MPa (20-58 psi) with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). It works in temperatures from -5 to 70 C and uses ISO VG 32 oil. The drain bowl holds 60 cc and the oil bowl holds 98 cc, with a total weight of 1020 g. The element is 40 um and the port is 3/8".

The N after the port code means no gauge is supplied with this unit. The gauge connection is 1/8", so you can add a circular gauge later if you need to read the set pressure. The N before the port code indicates the bowl is made of nylon, which is a material choice for your environment - confirm it suits your surroundings since the catalogue gives no specific material performance data.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GAFC Air Service Unit GAFC300N10LNK

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for GAFC300N10LNK and will confirm price, stock and lead time — usually within 7-8 hours.