The AirTAC Airtac GAFC Air Service Unit GAFC300N10LNWK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 3/8" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
This GAFC300 F.R.L. combination pairs a filter-regulator with a lubricator on one T-bracket, so the air is cleaned, set to pressure, then oil-misted in the last stage. The 3/8in port and 1020 g mass suit it for a single machine station or a small assembly bench where the line must stay compact.
The lower-pressure type regulates from 0.15 to 0.4 MPa (20-58 psi), with a 5 um element trapping fine particles before the lubricator adds its metered oil mist. A 60 cc condensate bowl and a 98 cc oil bowl set the service rhythm, and the nylon bowl material is a build choice - the catalogue gives no impact or chemical data, so confirm it suits your surroundings. No gauge is supplied; the 1/8in gauge connection is there if you add one.
| Model | Airtac GAFC Air Service Unit GAFC300N10LNWK |
|---|---|
| Series | GAFC300 F.R.L. combination |
| Port size | 3/8" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Nylon |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1020 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFC300 is 1/8" if you add one.
| GAFC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAFR300-10 filter & regulator, GAL300-10 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC300 · 3/8" · curve to 3500 L/min |
|---|---|
| One size down | GAFC200 |
| One size up | GAFC400 (curve to 6000 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Feed a bank of small solenoid valves on a test bench where the 5 um element protects fine orifices and the lower pressure range keeps actuation gentle.
Supply a pneumatic screwdriver or a small press at a single assembly station, where the compact two-piece build saves rail space and the 98 cc oil bowl lasts a shift.
Run a small lab fixture or a pick-and-place gripper that needs clean, regulated air at low pressure, with the nylon bowl offering a lightweight option for benchtop mounting.
The GAFC300 body with a 3/8in port sits between the smaller GAFC200 (1/4in, 590 g) and the larger GAFC400 (1/2in, 1810 g). The 5 um element filters finer than the standard 40 um, which helps precision valves but means more frequent element service. The semi-auto drain dumps condensate on each pressure drop, with a manual drain for on-demand use. The reverse-flow (reflux) valve is fitted, and the PT thread carries a gauge scale in MPa/psi - though this model ships without a gauge, so the set pressure cannot be read until you add one. The lubricator needs ISO VG 32 oil, and if the line must stay oil-free, choose a plain GAFR300-10 filter-regulator instead. Spares are the GAFR300-10 and GAL300-10, both orderable separately. With a 1.0 MPa max supply, you have about 0.6 MPa above the 0.4 MPa top of the regulated range, so plan the inlet pressure carefully if you need the full band.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR300-10 filter-regulator on that branch instead of the full combination.
This lower-pressure F.R.L. combination works from 0.15 to 0.4 MPa (20-58 psi), with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). It operates from -5 to 70 C and must not freeze. The drain bowl holds 60 cc and the oil bowl holds 98 cc. Recommended lubricant is ISO VG 32. The unit weighs 1020 g and has a 3/8in port.
The N after the port code means no gauge is supplied - the 1/8in gauge connection is there if you want to add one later. The K code means a reverse-flow (reflux) valve is fitted, which the catalogue shows as a separate pneumatic symbol. The nylon bowl is a build choice, but the catalogue gives no impact or chemical data, so confirm it fits your environment.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.