The AirTAC Airtac GAFC Air Service Unit GAFC300N10LWK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 3/8" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
This AirTAC GAFC300N10LWK is a two-piece F.R.L. combination on a T bracket: a filter-regulator body and a lubricator body. The 3/8in port, 5 um element, and lower-pressure range of 0.15-0.4 MPa (20-58 psi) make it a compact choice for precise, low-pressure pneumatic circuits.
The nylon bowl holds 60 cc of condensate, while the oil bowl holds 98 cc, and the whole unit weighs 1020 g. The 5 um element traps fine particles, and the semi-auto plus manual drain gives operators control over condensate removal. Air is filtered and regulated first, then oil mist is added last, so the regulator seat never sees oil.
| Model | Airtac GAFC Air Service Unit GAFC300N10LWK |
|---|---|
| Series | GAFC300 F.R.L. combination |
| Port size | 3/8" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Nylon |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1020 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.
| GAFC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAFR300-10 filter & regulator, GAL300-10 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC300 · 3/8" · curve to 3500 L/min |
|---|---|
| One size down | GAFC200 |
| One size up | GAFC400 (curve to 6000 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Set a stable 0.3 MPa for a delicate air bearing or a precision grinding spindle where standard 0.9 MPa regulation is too coarse and too high.
Feed a small laboratory test rig or a sampling valve system that requires clean, oiled air at a controlled low pressure without over-pressurizing sensitive components.
Power a soft-acting pneumatic clamp or a light-duty parts feeder on an assembly bench, where the 5 um element protects fine orifices in the tooling.
Choose the GAFC300N10LWK when your circuit needs a lower regulated pressure of 0.15-0.4 MPa (20-58 psi) and fine 5 um filtration. The nylon bowl is a build choice; the catalogue gives no impact or chemical data, so confirm it suits your environment. The semi-auto drain dumps on pressure drop, with a manual backup for on-demand use. A circular gauge is fitted, reading MPa/psi for the PT thread. The reverse-flow (reflux) valve is fitted, shown as a separate symbol in the catalogue. If the line must stay oil-free, omit the lubricator and choose a plain GAFR filter-regulator instead. Spares are orderable as GAFR300-10 and GAL300-10. Max supply of 1.0 MPa leaves about 0.6 MPa above the 0.4 MPa top of the range, so plan your inlet pressure accordingly.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR300-10 filter-regulator on that branch instead of the full combination.
This F.R.L. combination operates at 0.15-0.4 MPa (20-58 psi) with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). It works in -5 to 70 C temperatures, uses ISO VG 32 oil, has a 60 cc drain bowl and a 98 cc oil bowl, and weighs 1020 g.
The L code sets the 0.15-0.4 MPa range, suited for circuits that must not exceed 0.4 MPa. The W code specifies the 5 um element, which traps finer particles than the standard 40 um, protecting precision valves but requiring more frequent element service.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.