verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GAFC300 · F.R.L. Combination (Filter-Regulator + Lubricator)

Airtac GAFC Air Service Unit GAFC300N10LWK

The AirTAC Airtac GAFC Air Service Unit GAFC300N10LWK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 3/8" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).

  • TypeF.R.L. combination
  • Port size3/8"
  • Pressure range0.15 - 0.4 MPa (20 - 58 psi)
  • Filtering grade5 µm
  • Bowl materialNylon
  • Drainsemi-auto + manual
  • Pressure gaugeCircular, MPa / psi
  • Weight1020 g
$86.35 $95.87Save 9% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GAFC Air Service Unit GAFC300N10LWK

This AirTAC GAFC300N10LWK is a two-piece F.R.L. combination on a T bracket: a filter-regulator body and a lubricator body. The 3/8in port, 5 um element, and lower-pressure range of 0.15-0.4 MPa (20-58 psi) make it a compact choice for precise, low-pressure pneumatic circuits.

The nylon bowl holds 60 cc of condensate, while the oil bowl holds 98 cc, and the whole unit weighs 1020 g. The 5 um element traps fine particles, and the semi-auto plus manual drain gives operators control over condensate removal. Air is filtered and regulated first, then oil mist is added last, so the regulator seat never sees oil.

Airtac GAFC Air Service Unit GAFC300N10LWK Technical Specifications

ModelAirtac GAFC Air Service Unit GAFC300N10LWK
SeriesGAFC300 F.R.L. combination
Port size3/8" (PT thread)
Filtering grade5 µm
Pressure range0.15 - 0.4 MPa (20 - 58 psi)
TypeLower pressure
Bowl materialNylon
Drain typeSemi-auto drain + manual drain
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl60 cc
Capacity of oil bowl98 cc
Recommended lubricantISO VG 32 or equivalent
Weight1020 g

Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.

Model Code: Airtac GAFC Air Service Unit GAFC300N10LWK

GAFC300GA300 series F.R.L. unit — sets ports, bowl capacity and weight.
NBowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N).
10Port size 3/8". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2".
(blank)Drain: Semi-auto drain + manual drain.
LLower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L).
(blank)Circular pressure gauge fitted.
WFiltering grade 5 µm.
(blank)PT thread; gauge scale MPa / psi.
KReverse-flow (reflux) valve attached.

Constituent units, orderable separately as spares: GAFR300-10 filter & regulator, GAL300-10 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.

Size Class & Flow Envelope

  • GAFC2001/8"-1/4" · 1750 L/min
  • GAFC3001/4"-1/2" · 3500 L/min
  • GAFC4003/8"-1/2" · 6000 L/min
  • GAFC5003/4" · 7000 L/min
  • GAFC6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.

This modelGAFC300 · 3/8" · curve to 3500 L/min
One size downGAFC200
One size upGAFC400 (curve to 6000 L/min)
Build orderFilter & regulator → bracket → lubricator

Where the Airtac GAFC Air Service Unit GAFC300N10LWK Is Used

precision_manufacturing

Precision pressure setting

Set a stable 0.3 MPa for a delicate air bearing or a precision grinding spindle where standard 0.9 MPa regulation is too coarse and too high.

science

Lab pneumatic controls

Feed a small laboratory test rig or a sampling valve system that requires clean, oiled air at a controlled low pressure without over-pressurizing sensitive components.

handyman

Low-pressure assembly tools

Power a soft-acting pneumatic clamp or a light-duty parts feeder on an assembly bench, where the 5 um element protects fine orifices in the tooling.

Is the Airtac GAFC Air Service Unit GAFC300N10LWK the Right Air-Prep Unit?

Choose the GAFC300N10LWK when your circuit needs a lower regulated pressure of 0.15-0.4 MPa (20-58 psi) and fine 5 um filtration. The nylon bowl is a build choice; the catalogue gives no impact or chemical data, so confirm it suits your environment. The semi-auto drain dumps on pressure drop, with a manual backup for on-demand use. A circular gauge is fitted, reading MPa/psi for the PT thread. The reverse-flow (reflux) valve is fitted, shown as a separate symbol in the catalogue. If the line must stay oil-free, omit the lubricator and choose a plain GAFR filter-regulator instead. Spares are orderable as GAFR300-10 and GAL300-10. Max supply of 1.0 MPa leaves about 0.6 MPa above the 0.4 MPa top of the range, so plan your inlet pressure accordingly.

Quick checklist

  • ✓ Body size for your peak flow (3/8" here)
  • ✓ Standard 0.9 MPa or lower-pressure 0.4 MPa
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Element 40 µm or 5 µm
  • ✓ Thread & gauge scale (PT / G / NPT)
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter-regulator first, lubricator last.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Fill the oil bowl with ISO VG 32 or equivalent only.
  • check Drain condensate before the 60 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 1020 g unit on its bracket, not on the tubing.

The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR300-10 filter-regulator on that branch instead of the full combination.

Airtac GAFC Air Service Unit GAFC300N10LWK FAQ

This F.R.L. combination operates at 0.15-0.4 MPa (20-58 psi) with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). It works in -5 to 70 C temperatures, uses ISO VG 32 oil, has a 60 cc drain bowl and a 98 cc oil bowl, and weighs 1020 g.

The L code sets the 0.15-0.4 MPa range, suited for circuits that must not exceed 0.4 MPa. The W code specifies the 5 um element, which traps finer particles than the standard 40 um, protecting precision valves but requiring more frequent element service.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GAFC Air Service Unit GAFC300N10LWK

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for GAFC300N10LWK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.