The AirTAC Airtac GAFC Air Service Unit GAFC300N10SNK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 3/8" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
This AirTAC GAFC300N10SNK is a two-piece F.R.L. combination: a filter-regulator body paired with a lubricator, mounted together on a T-bracket with quick clamps. The 3/8in port size and 1020 g weight place it in the mid-range GAFC300 class, suitable for feeding a single machine station or a small bank of actuators. The nylon bowl is specified by the N code, and the 40 um element handles standard shop air.
The standard pressure range is 0.15-0.9 MPa (20-130 psi), with a max supply of 1.0 MPa (145 psi). Air is filtered and regulated in the first body, then the lubricator adds a metered oil mist downstream, so oil never passes back through the regulator seat. The 60 cc condensate bowl and 98 cc oil bowl define the service interval, and the unit must not freeze, with a rated range of -5 to 70 C.
| Model | Airtac GAFC Air Service Unit GAFC300N10SNK |
|---|---|
| Series | GAFC300 F.R.L. combination |
| Port size | 3/8" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Nylon |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1020 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFC300 is 1/8" if you add one.
| GAFC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAFR300-10 filter & regulator, GAL300-10 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC300 · 3/8" · curve to 3500 L/min |
|---|---|
| One size down | GAFC200 |
| One size up | GAFC400 (curve to 6000 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Feed a single-station pneumatic fixture on a CNC machining center. The 3/8in port and 1020 g weight suit a compact mounting plate, while the 40 um element protects the clamp valves from pipe scale.
Power a short belt conveyor with a single air motor or a pair of cylinders. The 60 cc condensate bowl handles typical moisture from a small compressor, and the semi-auto drain clears it on each shutdown.
Supply a manual assembly bench with a pneumatic screwdriver or a small press. The lubricator adds ISO VG 32 oil mist to the tool, and the 98 cc oil bowl keeps the lubricator topped up across a shift.
The GAFC300N10SNK uses a 3/8in port (code 10), sitting between the smaller GAFC200 (1/8in-1/4in, 590 g) and the larger GAFC400 (3/8in-1/2in, 1810 g) in the range. The nylon bowl is a build choice, not a performance upgrade, and the shared specification of 1.0 MPa max and -5 to 70 C applies to all bowl materials, so confirm it suits your environment. The drain is the standard semi-auto plus manual type: the semi-auto dumps condensate each time pressure drops, while the manual drain gives on-demand control. No gauge is fitted, so the 1/8in gauge connection is available if you add one later. The reverse-flow (reflux) valve is fitted, shown as a separate symbol in the catalogue. The 40 um element is the standard grade; the 5 um W option is available for finer filtration. Thread is PT with an MPa/psi gauge scale. Spare parts are orderable as GAFR300-10 and GAL300-10. The 1.0 MPa max supply leaves about 0.1 MPa above the 0.9 MPa top of the regulated range, so plan the supply pressure accordingly.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR300-10 filter-regulator on that branch instead of the full combination.
The GAFC300N10SNK operates at 0.15-0.9 MPa (20-130 psi), with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). The temperature range is -5 to 70 C and it must not freeze. The drain bowl holds 60 cc and the oil bowl holds 98 cc. Recommended lubricant is ISO VG 32. The unit weighs 1020 g and has a 3/8in port.
The N after the port code means no gauge is supplied. The gauge connection on the GAFC300 body is 1/8in, so you can fit a standard AirTAC gauge there if you need to read the set pressure. Without a gauge, the outlet pressure cannot be verified visually, so plan for a separate gauge or a test point.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.