The AirTAC Airtac GAFC Air Service Unit GAFC40010ALN is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 3/8" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
This AirTAC GAFC40010ALN is a two-piece F.R.L. combination: a filter-regulator body handles filtration and pressure setting, then a separate lubricator adds a metered oil mist downstream. The 3/8in port and 1810 g mass put it in the mid-size class, suited to feeding a multi-axis machine or a small production line. Its lower-pressure regulator is set for 0.15-0.4 MPa (20-58 psi), with a 40 um element as standard.
The automatic drain clears condensate from the 100 cc bowl without operator attention, while the 185 cc oil bowl keeps the lubricator running between refills. No gauge is supplied with this model, so the set pressure cannot be read without adding one to the 1/4in gauge connection. The PC bowl material is the standard build; confirm it suits your environment, as the catalogue gives no material-specific ratings.
| Model | Airtac GAFC Air Service Unit GAFC40010ALN |
|---|---|
| Series | GAFC400 F.R.L. combination |
| Port size | 3/8" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | PC |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1810 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFC400 is 1/4" if you add one.
| GAFC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/4" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAFR400-10 filter & regulator, GAL400-10 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC400 · 3/8" · curve to 6000 L/min |
|---|---|
| One size down | GAFC300 |
| One size up | GAFC500 (curve to 7000 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Feed a custom jig or fixture that requires clean, regulated air at a consistent lower pressure, such as a clamping station on a CNC workbench.
Supply a short conveyor section with lubricated air for pneumatic stops or guides, where the 3/8in port matches typical valve manifolds.
Operate small packaging machine cylinders that cycle frequently, benefiting from the automatic drain to minimize downtime on a busy line.
Choose the GAFC400 body when your line needs the 3/8in port and the 100 cc drain bowl capacity, stepping down to a GAFC300 (60 cc drain bowl) for lighter duty or up to a GAFC500 (108 cc drain bowl) for a 3/4in port. The A code specifies an automatic drain, which clears water without an operator - useful for unattended shifts or wet supply lines. The L type limits regulation to 0.15-0.4 MPa (20-58 psi), so confirm your actuators never need more than 0.4 MPa; if they might, the S type (0.15-0.9 MPa) is the safer choice. The N after the port means no gauge is fitted, but the 1/4in connection is ready for one. The PT thread suits standard pipe installations. For spares, order the GAFR400-10 filter-regulator and GAL400-10 lubricator separately. Note the 1.0 MPa max supply leaves about 0.6 MPa above the 0.4 MPa top of the range, so plan your inlet pressure accordingly.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR400-10 filter-regulator on that branch instead of the full combination.
This F.R.L. combination operates on air with a lower pressure range of 0.15-0.4 MPa (20-58 psi). Maximum pressure is 1.0 MPa (145 psi) and proof pressure is 1.5 MPa (215 psi). It works in temperatures from -5 to 70 C and should not freeze. The unit has a 100 cc drain bowl and a 185 cc oil bowl, weighs 1810 g, and uses ISO VG 32 or equivalent lubricant.
The 'N' in the code means no gauge is supplied. The GAFC400 body has a 1/4in gauge connection, so you can add a compatible pressure gauge to monitor the set pressure. Without one, you cannot read the regulated output directly, which is important for applications needing a precise 0.15-0.4 MPa setting.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.