The AirTAC Airtac GAFC Air Service Unit GAFC40010ALW is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 3/8" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
This GAFC40010ALW is a two-piece F.R.L. combination: a filter-regulator body paired with a lubricator, mounted on a shared T-bracket with quick clamps. The 3/8in port and 1810 g mass place it in the mid-range size class, suited for a machine header feeding several actuators. Air is filtered and set to pressure in the first body, then the lubricator adds a controlled oil mist last, so oil never travels back through the regulator seat.
The lower-pressure type regulates from 0.15 to 0.4 MPa (20-58 psi), with a 5 um element trapping fine particles for sensitive valves. The automatic drain clears condensate from the 100 cc bowl without an operator, while the 185 cc oil bowl sets the service interval for topping up ISO VG 32 lubricant. A circular gauge is fitted, reading MPa and psi on the default PT thread scale.
| Model | Airtac GAFC Air Service Unit GAFC40010ALW |
|---|---|
| Series | GAFC400 F.R.L. combination |
| Port size | 3/8" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | PC |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1810 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.
| GAFC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAFR400-10 filter & regulator, GAL400-10 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC400 · 3/8" · curve to 6000 L/min |
|---|---|
| One size down | GAFC300 |
| One size up | GAFC500 (curve to 7000 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Feed a bank of precision pneumatic valves on a packaging machine, where the 5 um element protects fine internal passages from particle wear.
Supply a controlled oil mist to slide ways and spindles on a CNC lathe, with the lower pressure range protecting sensitive metering units.
Provide filtered, regulated, lubricated air to a laboratory test bench with multiple small actuators, where the 0.4 MPa ceiling matches the rig's design pressure.
Choose the GAFC40010ALW when your line needs fine filtration and a regulated ceiling of 0.4 MPa, not the standard 0.9 MPa. The 5 um element suits precision pneumatic controls, though it will need more frequent service than a 40 um element. The automatic drain is the right call for unattended operation or wet supply lines, removing condensate from the 100 cc bowl without manual intervention. The PC bowl is the standard build; confirm it suits your environment, as the catalogue gives no material-specific chemical or temperature data. The circular gauge reads MPa and psi, matching the PT thread. For a line that must stay oil-free, omit the lubricator and select a plain GAFR400-10 filter-regulator instead. Spare parts are the GAFR400-10 and GAL400-10, both orderable separately. With a 1.0 MPa max supply, you have about 0.6 MPa of headroom above the 0.4 MPa top of the regulated range, so plan your inlet pressure accordingly.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR400-10 filter-regulator on that branch instead of the full combination.
The GAFC40010ALW operates from 0.15 to 0.4 MPa (20-58 psi), with a maximum pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). It handles temperatures from -5 to 70 C, uses ISO VG 32 lubricant, and weighs 1810 g. The drain bowl holds 100 cc and the oil bowl holds 185 cc.
The L in the code specifies the lower-pressure type, regulating from 0.15 to 0.4 MPa instead of the standard 0.15 to 0.9 MPa. This suits applications with sensitive components that must not see higher pressures, such as precision regulators or delicate actuators. If your machine may ever need more than 0.4 MPa, this is the wrong part.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.