The AirTAC Airtac GAFC Air Service Unit GAFC40010ALWK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 3/8" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
The GAFC40010ALWK is an F.R.L. combination built as two units on one T-shape bracket: the filter and regulator share a single body, and the lubricator adds a metered oil mist downstream. This 3/8in version regulates from 0.15 to 0.4 MPa (20-58 psi) and filters to 5 um, with a circular gauge reading MPa/psi.
The 100 cc condensate bowl and 185 cc oil bowl set the service rhythm, while the 1810 g mass calls for a proper panel or frame mount rather than tubing support. The automatic drain clears water without an operator, and the reverse-flow valve is fitted as an ordering option. The lower-pressure range makes this unit a poor fit if the machine may ever need more than 0.4 MPa.
| Model | Airtac GAFC Air Service Unit GAFC40010ALWK |
|---|---|
| Series | GAFC400 F.R.L. combination |
| Port size | 3/8" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | PC |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1810 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.
| GAFC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAFR400-10 filter & regulator, GAL400-10 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC400 · 3/8" · curve to 6000 L/min |
|---|---|
| One size down | GAFC300 |
| One size up | GAFC500 (curve to 7000 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Feed a bank of precision pneumatic valves on a small assembly station where the 5 um element protects fine internal clearances and the 0.4 MPa ceiling matches the valve spec.
Run a row of short-stroke actuators on a carton erector or case packer, where the automatic drain keeps condensate out of the line during long unattended shifts.
Supply a test fixture or lab instrument that needs clean, regulated air at modest pressure, with the lower range preventing accidental over-pressurization of sensitive parts.
Choose the GAFC40010ALWK when your line needs 3/8in ports and a regulated ceiling of 0.4 MPa. The L type tops out there, so confirm the downstream demand stays below that figure. The 5 um element traps finer particles than the standard 40 um but will need more frequent service. The PC bowl is the default build; confirm it suits your environment, since the catalogue gives no material-specific ratings. The automatic drain suits unattended operation, and the PT thread carries a gauge scaled in MPa/psi. The reverse-flow valve is fitted per the K code. Spares are the GAFR400-10 filter-regulator and GAL400-10 lubricator, both orderable separately. With a 1.0 MPa max supply, you have about 0.6 MPa of headroom above the 0.4 MPa top of the regulated range.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR400-10 filter-regulator on that branch instead of the full combination.
This F.R.L. combination operates on air from 0.15 to 0.4 MPa (20-58 psi), with a maximum pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). The temperature range is -5 to 70 C, and the recommended lubricant is ISO VG 32. The drain bowl holds 100 cc and the oil bowl 185 cc, with a total weight of 1810 g.
The L in the code specifies the lower-pressure type, regulating from 0.15 to 0.4 MPa instead of the standard 0.15 to 0.9 MPa. The K code adds a reverse-flow valve, which the catalogue shows as a separate pneumatic symbol. This unit also carries a 5 um element and an automatic drain, so it is built for finer filtration and unattended operation at modest pressures.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.