The AirTAC Airtac GAFC Air Service Unit GAFC40010ASNW is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 3/8" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
This AirTAC GAFC40010ASNW is a two-piece F.R.L. combination: a filter-regulator body paired with a lubricator, mounted on a shared T-bracket with quick clamps. The 3/8in port and 1810 g mass place it in the mid-size class, suited to a machine header or a small multi-station line rather than a single actuator.
The filter-regulator stage cleans the air and sets pressure to 0.15-0.9 MPa (20-130 psi), then the lubricator adds a metered oil mist downstream. A 5 um element traps fine particles for sensitive valves. The automatic drain clears condensate without an operator, and the 100 cc drain bowl plus 185 cc oil bowl define the service interval.
| Model | Airtac GAFC Air Service Unit GAFC40010ASNW |
|---|---|
| Series | GAFC400 F.R.L. combination |
| Port size | 3/8" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | PC |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1810 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFC400 is 1/4" if you add one.
| GAFC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/4" gauge connection. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAFR400-10 filter & regulator, GAL400-10 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC400 · 3/8" · curve to 6000 L/min |
|---|---|
| One size down | GAFC300 |
| One size up | GAFC500 (curve to 7000 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Feed a 3/8in line to solenoid valves on a CNC lathe's coolant system. The 5 um element protects fine orifices, and the automatic drain keeps the bowl clear during long unattended runs.
Supply a multi-station assembly bench where each station has a small actuator. The 185 cc oil bowl supports several lubricated tools between refills, and the 1810 g unit mounts securely on a frame.
Prepare air for a carton erector's pneumatic cylinders and grippers. The 0.15-0.9 MPa range covers typical setpoints, while the 100 cc condensate bowl reduces maintenance frequency on a busy line.
Choose the GAFC400 body when a 3/8in port with a 6000 L/min flow envelope (plotted at 0.7 MPa inlet) suits your line. The A code specifies an automatic drain, so no manual attention is needed for condensate. The N after the port means no gauge is fitted; the 1/4in gauge connection allows adding one later. The 5 um element filters finer than the standard 40 um, but expect more frequent element service. PT threads carry a MPa/psi gauge scale if a gauge is added. The two units are separately orderable as GAFR400-10 and GAL400-10, so a worn element or damaged bowl does not force a full replacement. If the line must stay oil-free, omit the lubricator and choose a plain GAFR400-10 filter-regulator instead. Max supply of 1.0 MPa leaves about 0.1 MPa above the 0.9 MPa top of the regulated range, so plan inlet pressure carefully if you need the full band.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR400-10 filter-regulator on that branch instead of the full combination.
The GAFC40010ASNW operates from 0.15 to 0.9 MPa (20-130 psi) with a maximum pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). It works in -5 to 70 C temperatures and needs ISO VG 32 lubricant. The drain bowl holds 100 cc, the oil bowl 185 cc, and the unit weighs 1810 g. It has a 3/8in port and uses a 5 um filter element.
The N after the port code means no gauge is supplied. The GAFC400 body has a 1/4in gauge connection, so you can add a compatible gauge later. Without one, the set pressure cannot be read directly on the unit, so plan to install a gauge if operators need to verify the outlet setting.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.