The AirTAC Airtac GAFC Air Service Unit GAFC40010L is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 3/8" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
This AirTAC GAFC40010L is a two-piece F.R.L. combination: a filter-regulator body handles both filtration and pressure control, then the lubricator adds a metered oil mist downstream. The 3/8in port and 1810 g mass place it in the mid-size class, suited to multi-actuator machines where a smaller unit would struggle.
The lower-pressure type regulates from 0.15 to 0.4 MPa (20-58 psi), with a 40 um element as standard. Its 100 cc condensate bowl and 185 cc oil bowl mean fewer service visits than smaller bodies. The circular gauge reads in MPa/psi, matching the PT thread. Max supply is 1.0 MPa (145 psi), proof pressure 1.5 MPa (215 psi), and the unit operates from -5 to 70 C.
| Model | Airtac GAFC Air Service Unit GAFC40010L |
|---|---|
| Series | GAFC400 F.R.L. combination |
| Port size | 3/8" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | PC |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1810 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.
| GAFC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAFR400-10 filter & regulator, GAL400-10 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC400 · 3/8" · curve to 6000 L/min |
|---|---|
| One size down | GAFC300 |
| One size up | GAFC500 (curve to 7000 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Feed a bench-top pneumatic press or torque tool where the regulator is set to 0.3 MPa. The 3/8in port and 1810 g mass handle the duty without oversized hardware.
Supply atomizing air to spray guns at a controlled 0.25-0.35 MPa. The lower-pressure range keeps the finish consistent, and the 185 cc oil bowl keeps the lubricator running between shifts.
Drive small pneumatic cylinders in a test fixture at 0.2 MPa. The 40 um element protects the valves, while the semi-auto drain clears condensate without constant attention.
Choose this GAFC40010L when your application needs a regulated band capped at 0.4 MPa (20-58 psi). The L type suits low-pressure circuits, but if the machine may ever require more than 0.4 MPa, select the standard S type instead. The PC bowl is the default build; confirm it suits your environment, as the catalogue gives no material-specific ratings. The semi-auto drain dumps condensate on pressure drops, with a manual override for on-demand use.
The 3/8in port pairs with the GAFC300 (1/4in-1/2in) below and the GAFC500 (3/4in) above. The 40 um element handles general shop air; upgrade to the W code for 5 um filtration if you feed precision valves. The PT thread carries an MPa/psi gauge scale. Spares are orderable as GAFR400-10 and GAL400-10. With a 1.0 MPa max supply, you have about 0.6 MPa of headroom above the 0.4 MPa top of the regulated range, so plan your inlet pressure accordingly.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR400-10 filter-regulator on that branch instead of the full combination.
The GAFC40010L operates from 0.15 to 0.4 MPa (20-58 psi), with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). It works in temperatures from -5 to 70 C. The drain bowl holds 100 cc, the oil bowl 185 cc, and the unit weighs 1810 g. Use ISO VG 32 oil in the lubricator.
The L type is designed for circuits that never need more than 0.4 MPa (58 psi), such as certain spraying or low-force clamping applications. It gives finer adjustment within that band. If your machine might need higher pressure later, choose the standard S type (0.15-0.9 MPa) instead, as the L type cannot be modified.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.