verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GAFC400 · F.R.L. Combination (Filter-Regulator + Lubricator)

Airtac GAFC Air Service Unit GAFC40010LK

The AirTAC Airtac GAFC Air Service Unit GAFC40010LK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 3/8" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).

  • TypeF.R.L. combination
  • Port size3/8"
  • Pressure range0.15 - 0.4 MPa (20 - 58 psi)
  • Filtering grade40 µm
  • Bowl materialPC
  • Drainsemi-auto + manual
  • Pressure gaugeCircular, MPa / psi
  • Weight1810 g
$105.96 $116.80Save 9% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GAFC Air Service Unit GAFC40010LK

This GAFC40010LK is a two-piece F.R.L. combination: a filter-regulator body paired with a lubricator, joined on a T-bracket with quick clamps. The 3/8in port and 1810 g mass place it in the mid-size class, where the 100 cc condensate bowl and 185 cc oil bowl set the service rhythm. The lower-pressure regulator is set for 0.15-0.4 MPa (20-58 psi), with a 40 um element filtering the air before the lubricator adds a metered oil mist downstream.

Air is cleaned and regulated in the first body, then the lubricator introduces oil mist last, so oil never passes back through the regulator seat. The circular gauge is fitted with an MPa/psi scale for the PT thread, and the reverse-flow (reflux) valve is included. With a 1.0 MPa (145 psi) maximum supply, the unit operates well within its proof pressure of 1.5 MPa (215 psi) across the -5 to 70 C range.

Airtac GAFC Air Service Unit GAFC40010LK Technical Specifications

ModelAirtac GAFC Air Service Unit GAFC40010LK
SeriesGAFC400 F.R.L. combination
Port size3/8" (PT thread)
Filtering grade40 µm
Pressure range0.15 - 0.4 MPa (20 - 58 psi)
TypeLower pressure
Bowl materialPC
Drain typeSemi-auto drain + manual drain
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl100 cc
Capacity of oil bowl185 cc
Recommended lubricantISO VG 32 or equivalent
Weight1810 g

Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.

Model Code: Airtac GAFC Air Service Unit GAFC40010LK

GAFC400GA400 series F.R.L. unit — sets ports, bowl capacity and weight.
(blank)Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N).
10Port size 3/8". This body offers 10 = 3/8", 15 = 1/2".
(blank)Drain: Semi-auto drain + manual drain.
LLower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L).
(blank)Circular pressure gauge fitted.
(blank)Filtering grade 40 µm.
(blank)PT thread; gauge scale MPa / psi.
KReverse-flow (reflux) valve attached.

Constituent units, orderable separately as spares: GAFR400-10 filter & regulator, GAL400-10 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.

Size Class & Flow Envelope

  • GAFC2001/8"-1/4" · 1750 L/min
  • GAFC3001/4"-1/2" · 3500 L/min
  • GAFC4003/8"-1/2" · 6000 L/min
  • GAFC5003/4" · 7000 L/min
  • GAFC6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.

This modelGAFC400 · 3/8" · curve to 6000 L/min
One size downGAFC300
One size upGAFC500 (curve to 7000 L/min)
Build orderFilter & regulator → bracket → lubricator

Where the Airtac GAFC Air Service Unit GAFC40010LK Is Used

precision_manufacturing

Precision Pressure Setting

Set a precise 0.3 MPa (43 psi) for a delicate clamping fixture on a CNC machine, where the lower-pressure range gives finer adjustment resolution than a standard 0.9 MPa regulator.

factory

Assembly Line Lubrication

Feed a multi-spindle nutrunner on an assembly line with filtered, regulated air and a consistent oil mist, keeping the tool's internal vanes lubricated across a full shift.

engineering

Low-Pressure Test Rig

Supply a leak-testing rig that operates at 0.2 MPa (29 psi) with clean, oil-misted air, using the 100 cc condensate bowl to handle moisture from a humid compressor line.

Is the Airtac GAFC Air Service Unit GAFC40010LK the Right Air-Prep Unit?

Choose the GAFC40010LK when your line needs regulated air at 0.15-0.4 MPa (20-58 psi) and you want the convenience of a combined filter-regulator with a lubricator. The PC bowl is the standard build, while the semi-auto drain dumps condensate on pressure drop and the manual drain works on demand. The 40 um element suits general pneumatic circuits, and the PT thread with MPa/psi gauge scale matches standard regional fittings. Since this is a lower-pressure type, confirm your machine never needs more than 0.4 MPa, or select a standard S-type unit instead. The reverse-flow valve is fitted per the K code, and the two units are separately orderable as GAFR400-10 and GAL400-10. If your line must stay oil-free, choose a plain GAFR filter-regulator without the lubricator. The 1.0 MPa max supply leaves about 0.6 MPa above the 0.4 MPa top of the range, giving you a comfortable operating margin below the maximum.

Quick checklist

  • ✓ Body size for your peak flow (3/8" here)
  • ✓ Standard 0.9 MPa or lower-pressure 0.4 MPa
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Element 40 µm or 5 µm
  • ✓ Thread & gauge scale (PT / G / NPT)
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter-regulator first, lubricator last.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Fill the oil bowl with ISO VG 32 or equivalent only.
  • check Drain condensate before the 100 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 1810 g unit on its bracket, not on the tubing.

The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR400-10 filter-regulator on that branch instead of the full combination.

Airtac GAFC Air Service Unit GAFC40010LK FAQ

The GAFC40010LK operates at 0.15-0.4 MPa (20-58 psi) with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). It has a 40 um element, a 100 cc drain bowl, a 185 cc oil bowl, and weighs 1810 g. The temperature range is -5 to 70 C, and the recommended lubricant is ISO VG 32.

The L type tops out at 0.4 MPa, which is about 44% of the standard type's 0.9 MPa ceiling. If your application might ever need more than 0.4 MPa, this is the wrong part. The lower range does give finer adjustment for low-pressure tasks, but the 1.0 MPa max supply still leaves 0.6 MPa of headroom above the regulated band.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GAFC Air Service Unit GAFC40010LK

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for GAFC40010LK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.