The AirTAC Airtac GAFC Air Service Unit GAFC40010LK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 3/8" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
This GAFC40010LK is a two-piece F.R.L. combination: a filter-regulator body paired with a lubricator, joined on a T-bracket with quick clamps. The 3/8in port and 1810 g mass place it in the mid-size class, where the 100 cc condensate bowl and 185 cc oil bowl set the service rhythm. The lower-pressure regulator is set for 0.15-0.4 MPa (20-58 psi), with a 40 um element filtering the air before the lubricator adds a metered oil mist downstream.
Air is cleaned and regulated in the first body, then the lubricator introduces oil mist last, so oil never passes back through the regulator seat. The circular gauge is fitted with an MPa/psi scale for the PT thread, and the reverse-flow (reflux) valve is included. With a 1.0 MPa (145 psi) maximum supply, the unit operates well within its proof pressure of 1.5 MPa (215 psi) across the -5 to 70 C range.
| Model | Airtac GAFC Air Service Unit GAFC40010LK |
|---|---|
| Series | GAFC400 F.R.L. combination |
| Port size | 3/8" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | PC |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1810 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.
| GAFC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAFR400-10 filter & regulator, GAL400-10 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC400 · 3/8" · curve to 6000 L/min |
|---|---|
| One size down | GAFC300 |
| One size up | GAFC500 (curve to 7000 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Set a precise 0.3 MPa (43 psi) for a delicate clamping fixture on a CNC machine, where the lower-pressure range gives finer adjustment resolution than a standard 0.9 MPa regulator.
Feed a multi-spindle nutrunner on an assembly line with filtered, regulated air and a consistent oil mist, keeping the tool's internal vanes lubricated across a full shift.
Supply a leak-testing rig that operates at 0.2 MPa (29 psi) with clean, oil-misted air, using the 100 cc condensate bowl to handle moisture from a humid compressor line.
Choose the GAFC40010LK when your line needs regulated air at 0.15-0.4 MPa (20-58 psi) and you want the convenience of a combined filter-regulator with a lubricator. The PC bowl is the standard build, while the semi-auto drain dumps condensate on pressure drop and the manual drain works on demand. The 40 um element suits general pneumatic circuits, and the PT thread with MPa/psi gauge scale matches standard regional fittings. Since this is a lower-pressure type, confirm your machine never needs more than 0.4 MPa, or select a standard S-type unit instead. The reverse-flow valve is fitted per the K code, and the two units are separately orderable as GAFR400-10 and GAL400-10. If your line must stay oil-free, choose a plain GAFR filter-regulator without the lubricator. The 1.0 MPa max supply leaves about 0.6 MPa above the 0.4 MPa top of the range, giving you a comfortable operating margin below the maximum.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR400-10 filter-regulator on that branch instead of the full combination.
The GAFC40010LK operates at 0.15-0.4 MPa (20-58 psi) with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). It has a 40 um element, a 100 cc drain bowl, a 185 cc oil bowl, and weighs 1810 g. The temperature range is -5 to 70 C, and the recommended lubricant is ISO VG 32.
The L type tops out at 0.4 MPa, which is about 44% of the standard type's 0.9 MPa ceiling. If your application might ever need more than 0.4 MPa, this is the wrong part. The lower range does give finer adjustment for low-pressure tasks, but the 1.0 MPa max supply still leaves 0.6 MPa of headroom above the regulated band.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.