The AirTAC Airtac GAFC Air Service Unit GAFC40010LN is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 3/8" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
This GAFC40010LN is a two-piece F.R.L. combination: a filter-regulator body paired with a lubricator, mounted on a T-bracket with quick clamps. The 3/8in port and 1810 g mass put it in the mid-size class, suited for feeding a multi-axis machine or a small production line. It regulates in the lower band of 0.15-0.4 MPa (20-58 psi), with a 40 um element as standard.
The filter and regulator share one body, so air is cleaned and set to pressure before the lubricator adds a metered oil mist last. The 100 cc condensate bowl and 185 cc oil bowl define the service interval, and with the semi-auto plus manual drain, condensate dumps on each pressure drop or on demand. No gauge is supplied; the 1/4in gauge connection is ready for one if you need to read the set pressure.
| Model | Airtac GAFC Air Service Unit GAFC40010LN |
|---|---|
| Series | GAFC400 F.R.L. combination |
| Port size | 3/8" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | PC |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1810 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFC400 is 1/4" if you add one.
| GAFC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/4" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAFR400-10 filter & regulator, GAL400-10 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC400 · 3/8" · curve to 6000 L/min |
|---|---|
| One size down | GAFC300 |
| One size up | GAFC500 (curve to 7000 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Feed a pneumatic screwdriver or torque tool on an assembly bench, where the 0.15-0.4 MPa range protects delicate fastening operations from over-torque.
Supply a paint spray gun with regulated low-pressure air, keeping the atomization consistent while the 40 um element traps particles that could mar the finish.
Run a small pneumatic test rig or air bearing in a laboratory setting, where the lower pressure band and clean, lubricated air suit sensitive instruments.
Choose this GAFC40010LN when your application runs at low pressure, up to 0.4 MPa (58 psi). The L type tops out there, so if the machine may ever need more, select the standard S type instead. The PC bowl is the default build; confirm it suits your surroundings, as the catalogue gives no material-specific resistance data. The semi-auto and manual drain pair suits attended lines where operators can check the bowl. The 40 um element handles general workshop air; step to the 5 um W option for finer filtration. The PT thread with MPa/psi gauge scale matches common regional fittings, and a gauge can be added at the 1/4in connection. Spares are orderable as GAFR400-10 and GAL400-10. With a 1.0 MPa max supply, you have about 0.6 MPa of headroom above the 0.4 MPa top of the regulated range.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR400-10 filter-regulator on that branch instead of the full combination.
This F.R.L. combination operates at 0.15-0.4 MPa (20-58 psi) with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). It works in -5 to 70 C temperatures and needs ISO VG 32 lubricant. The drain bowl holds 100 cc and the oil bowl 185 cc, with a total weight of 1810 g.
The N in the code after the port means no gauge is supplied. The GAFC400 body has a 1/4in gauge connection, so you can add a circular gauge later to read the set pressure. Without one, the outlet pressure cannot be monitored directly on the unit.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.