AirTAC GAFC400 · F.R.L. Combination (Filter-Regulator + Lubricator)

Airtac GAFC Air Service Unit GAFC40010LNWK

The AirTAC Airtac GAFC Air Service Unit GAFC40010LNWK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 3/8" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).

  • TypeF.R.L. combination
  • Port size3/8"
  • Pressure range0.15 - 0.4 MPa (20 - 58 psi)
  • Filtering grade5 µm
  • Bowl materialPC
  • Drainsemi-auto + manual
  • Pressure gaugeNot fitted
  • Weight1810 g
$100.54 $111.01Save 9% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GAFC Air Service Unit GAFC40010LNWK

This AirTAC GAFC40010LNWK is an F.R.L. combination where the filter and pressure regulator share one body, and a lubricator is mounted alongside on a T-bracket with quick clamps. It handles a 3/8in port and weighs 1810 g, placing it in the mid-size class for machine-level air preparation. The 5 um element traps fine particles for sensitive valves, while the lower-pressure regulator tops out at 0.4 MPa (20-58 psi).

Air passes through the filter-regulator first, then the lubricator adds a controlled oil mist downstream, so oil never travels back through the regulator seat. The 100 cc condensate bowl and 185 cc oil bowl set the service rhythm, and the semi-auto drain dumps on pressure drops while the manual drain works on demand. No gauge is fitted, so the 1/4in gauge port on the body is where a gauge would go if you need to read the set pressure.

Airtac GAFC Air Service Unit GAFC40010LNWK Technical Specifications

ModelAirtac GAFC Air Service Unit GAFC40010LNWK
SeriesGAFC400 F.R.L. combination
Port size3/8" (PT thread)
Filtering grade5 µm
Pressure range0.15 - 0.4 MPa (20 - 58 psi)
TypeLower pressure
Bowl materialPC
Drain typeSemi-auto drain + manual drain
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl100 cc
Capacity of oil bowl185 cc
Recommended lubricantISO VG 32 or equivalent
Weight1810 g

Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFC400 is 1/4" if you add one.

Model Code: Airtac GAFC Air Service Unit GAFC40010LNWK

GAFC400GA400 series F.R.L. unit — sets ports, bowl capacity and weight.
(blank)Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N).
10Port size 3/8". This body offers 10 = 3/8", 15 = 1/2".
(blank)Drain: Semi-auto drain + manual drain.
LLower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L).
NNo pressure gauge; 1/4" gauge connection.
WFiltering grade 5 µm.
(blank)PT thread; gauge scale MPa / psi.
KReverse-flow (reflux) valve attached.

Constituent units, orderable separately as spares: GAFR400-10 filter & regulator, GAL400-10 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.

Size Class & Flow Envelope

  • GAFC2001/8"-1/4" · 1750 L/min
  • GAFC3001/4"-1/2" · 3500 L/min
  • GAFC4003/8"-1/2" · 6000 L/min
  • GAFC5003/4" · 7000 L/min
  • GAFC6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.

This modelGAFC400 · 3/8" · curve to 6000 L/min
One size downGAFC300
One size upGAFC500 (curve to 7000 L/min)
Build orderFilter & regulator → bracket → lubricator

Where the Airtac GAFC Air Service Unit GAFC40010LNWK Is Used

precision_manufacturing

Low-Pressure Assembly Tools

Feed a 3/8in line to pneumatic screwdrivers or torque tools on an assembly bench, where the 0.4 MPa ceiling prevents over-torquing delicate fasteners.

science

Lab Air Circuits

Supply filtered, lubricated air to a lab fixture that cycles small cylinders at controlled low pressure, with the 5 um element protecting fine orifices in solenoid valves.

packaging

Packaging Line Sensors

Run a low-pressure air circuit for sensing and light actuation on a packaging machine, where the 100 cc bowl handles condensate between scheduled maintenance checks.

Is the Airtac GAFC Air Service Unit GAFC40010LNWK the Right Air-Prep Unit?

Choose this GAFC40010LNWK when your line needs 3/8in ports and a regulated ceiling of 0.4 MPa, not the standard 0.9 MPa. The L type suits low-pressure circuits, but if the machine may ever need more than 0.4 MPa, step up to the S type instead. The 5 um element filters finer than the standard 40 um, trading more frequent element service for cleaner air to precision components. The PC bowl is the default build; confirm it suits your environment since the catalogue gives no material-specific ratings. The reverse-flow (reflux) valve is fitted per the K code, and the PT thread carries the MPa/psi gauge scale if you add a gauge later. Spare parts are GAFR400-10 and GAL400-10, both orderable separately. With a 1.0 MPa max supply, you have about 0.6 MPa of headroom above the 0.4 MPa top of the regulated range, so plan the inlet pressure accordingly.

Quick checklist

  • ✓ Body size for your peak flow (3/8" here)
  • ✓ Standard 0.9 MPa or lower-pressure 0.4 MPa
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Element 40 µm or 5 µm
  • ✓ Thread & gauge scale (PT / G / NPT)
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter-regulator first, lubricator last.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Fill the oil bowl with ISO VG 32 or equivalent only.
  • check Drain condensate before the 100 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 1810 g unit on its bracket, not on the tubing.

The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR400-10 filter-regulator on that branch instead of the full combination.

Airtac GAFC Air Service Unit GAFC40010LNWK FAQ

The GAFC40010LNWK operates at 0.15-0.4 MPa (20-58 psi) with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). It works in -5 to 70 C temperatures and needs ISO VG 32 lubricant. The drain bowl holds 100 cc, the oil bowl holds 185 cc, and the unit weighs 1810 g.

The N after the port code means no gauge is supplied, so you cannot read the set pressure without adding one to the 1/4in gauge connection. The K code means a reverse-flow (reflux) valve is fitted, which the catalogue shows as a separate pneumatic symbol.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GAFC Air Service Unit GAFC40010LNWK

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for GAFC40010LNWK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.