The AirTAC Airtac GAFC Air Service Unit GAFC40010LW is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 3/8" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
This GAFC40010LW is a two-piece F.R.L. combination rated for a lower pressure band of 0.15-0.4 MPa (20-58 psi). The first body houses the filter and the regulator together, so the 3/8in air is cleaned and set to pressure before it moves on. The second body is the lubricator, which meters ISO VG 32 oil mist into the airstream last, keeping oil away from the regulator seat.
The 5 um element traps finer particles than the standard 40 um grade, which suits precision valves or instrument circuits that need cleaner air. With a 100 cc condensate bowl and a 185 cc oil bowl, this 1810 g unit needs less frequent attention than smaller bodies in the GAFC range. A circular gauge is fitted, reading in MPa and psi for the PT thread.
| Model | Airtac GAFC Air Service Unit GAFC40010LW |
|---|---|
| Series | GAFC400 F.R.L. combination |
| Port size | 3/8" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | PC |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1810 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.
| GAFC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAFR400-10 filter & regulator, GAL400-10 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC400 · 3/8" · curve to 6000 L/min |
|---|---|
| One size down | GAFC300 |
| One size up | GAFC500 (curve to 7000 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Feed a sensitive pneumatic positioner or a precision grinding spindle with a stable 0.15-0.4 MPa supply, where the finer 5 um element protects close-tolerance components.
Run a film-sealing or carton-erecting station that operates below 0.4 MPa, using the lower-pressure regulator to avoid over-pressurizing delicate grippers or sensors.
Supply a lab analyzer or a pneumatic test fixture that requires cleaner air and a modest pressure ceiling, with the 5 um element filtering out fine particulates.
Choose the GAFC400 body for a 3/8in line that needs a 6000 L/min flow envelope at 0.7 MPa inlet, as plotted in the catalogue curve. The L type tops out at 0.4 MPa, so if your machine may ever need more than that, select the S type instead. The PC bowl is the standard build; the C or N codes change the material without altering the -5 to 70 C rating, so confirm compatibility for your surroundings. The blank drain code means both a semi-auto drain and a manual drain are fitted, giving you a backup for condensate removal. The 5 um element is the finer filtration choice, but it will need more frequent service than a 40 um element. The PT thread comes with a gauge scaled in MPa and psi. Replacement units are orderable as GAFR400-10 and GAL400-10. The 1.0 MPa max supply leaves about 0.6 MPa above the 0.4 MPa top of the range, so you have ample inlet headroom for this lower-pressure regulator.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR400-10 filter-regulator on that branch instead of the full combination.
This F.R.L. combination operates at 0.15-0.4 MPa (20-58 psi) with a max pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It is rated for -5 to 70 C and uses ISO VG 32 oil. The drain bowl holds 100 cc and the oil bowl holds 185 cc, with a total weight of 1810 g. The 3/8in port and 5 um element make it suitable for cleaner, lower-pressure duties.
The L in the code specifies the lower-pressure type, which regulates from 0.15 to 0.4 MPa instead of the standard 0.15-0.9 MPa. This is for applications that need a precise, lower ceiling and do not require higher pressures. If your process might need more than 0.4 MPa, choose the S type instead to avoid replacing the unit later.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.