The AirTAC Airtac GAFC Air Service Unit GAFC40010LWK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 3/8" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
This AirTAC GAFC40010LWK is a two-piece F.R.L. combination: a filter-regulator body paired with a lubricator on a shared T-bracket. Air is cleaned and set to pressure in the first unit, then a metered oil mist is added downstream, so oil never travels back through the regulator seat. The 3/8in port and 1810 g mass place it in the mid-size class, where a proper panel mount is expected rather than support from the tubing.
The lower-pressure regulator is set for 0.15-0.4 MPa (20-58 psi), and the 5 um element traps finer particles than the standard 40 um grade. A circular gauge is fitted with an MPa/psi scale, and the 100 cc condensate bowl plus 185 cc oil bowl define the service interval. The reverse-flow valve is fitted as an ordering difference, and the two units are separately orderable as GAFR400-10 and GAL400-10.
| Model | Airtac GAFC Air Service Unit GAFC40010LWK |
|---|---|
| Series | GAFC400 F.R.L. combination |
| Port size | 3/8" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | PC |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1810 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.
| GAFC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAFR400-10 filter & regulator, GAL400-10 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC400 · 3/8" · curve to 6000 L/min |
|---|---|
| One size down | GAFC300 |
| One size up | GAFC500 (curve to 7000 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Feed a 3/8in line to a precision clamping fixture where the lower 0.15-0.4 MPa range protects delicate workpieces from over-force. The 5 um element keeps fine particles from reaching sensitive clamp valves.
Supply a lab bench with filtered and regulated air for pneumatic actuators on test equipment. The 5 um filtration and lower pressure range suit instruments that need gentle, consistent actuation.
Run a light packaging line's pneumatic sensors and small cylinders at a controlled lower pressure. The 185 cc oil bowl supports extended operation between lubricator refills.
Choose the GAFC400 body when a 3/8in port and 1810 g mass suit the machine, with the 100 cc drain bowl and 185 cc oil bowl setting the attendance schedule. The PC bowl is the standard build; confirm it suits the surroundings, since the catalogue gives no material-specific ratings. The semi-auto drain dumps condensate on each pressure drop, with a manual drain for on-demand use. The 5 um element is for finer filtration, but expect more frequent element service than a 40 um grade. The PT thread carries an MPa/psi gauge scale, and the lower-pressure L type tops out at 0.4 MPa, so verify the application never needs more. The reverse-flow valve is fitted per the K code. For oil-free lines, omit the lubricator and choose a plain GAFR filter-regulator instead. With a 1.0 MPa max supply, there is about 0.6 MPa above the 0.4 MPa top of the range, so plan the inlet pressure accordingly.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR400-10 filter-regulator on that branch instead of the full combination.
The GAFC40010LWK operates at 0.15-0.4 MPa (20-58 psi) with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). It works in -5 to 70 C temperatures and uses ISO VG 32 lubricant. The unit weighs 1810 g, has a 100 cc drain bowl and a 185 cc oil bowl, and uses a 5 um filter element.
The K code indicates the reverse-flow (reflux) valve is fitted. The catalogue shows this as a separate pneumatic symbol. The two main units are a GAFR400-10 filter-regulator and a GAL400-10 lubricator, both with the same 3/8in port.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.