verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GAFC400 · F.R.L. Combination (Filter-Regulator + Lubricator)

Airtac GAFC Air Service Unit GAFC40010SNWK

The AirTAC Airtac GAFC Air Service Unit GAFC40010SNWK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 3/8" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination
  • Port size3/8"
  • Pressure range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • Bowl materialPC
  • Drainsemi-auto + manual
  • Pressure gaugeNot fitted
  • Weight1810 g
$100.54 $111.01Save 9% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GAFC Air Service Unit GAFC40010SNWK

The GAFC40010SNWK is a two-piece F.R.L. combination: a filter-regulator body paired with a lubricator, mounted on a T-bracket with quick clamps. Air enters the 3/8" port, gets filtered and regulated in the first body, then the lubricator adds a controlled oil mist last. This unit operates in the standard 0.15-0.9 MPa (20-130 psi) range and uses a 5 um element for finer filtration.

With a 1810 g mass and 100 cc condensate plus 185 cc oil bowls, this size class suits machines needing a stable air supply with fewer refill stops. The semi-auto drain dumps condensate on pressure drops, while the manual drain works on demand. No gauge is fitted, so the 1/4" gauge connection is available if you add one later.

Airtac GAFC Air Service Unit GAFC40010SNWK Technical Specifications

ModelAirtac GAFC Air Service Unit GAFC40010SNWK
SeriesGAFC400 F.R.L. combination
Port size3/8" (PT thread)
Filtering grade5 µm
Pressure range0.15 - 0.9 MPa (20 - 130 psi)
TypeStandard
Bowl materialPC
Drain typeSemi-auto drain + manual drain
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl100 cc
Capacity of oil bowl185 cc
Recommended lubricantISO VG 32 or equivalent
Weight1810 g

Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFC400 is 1/4" if you add one.

Model Code: Airtac GAFC Air Service Unit GAFC40010SNWK

GAFC400GA400 series F.R.L. unit — sets ports, bowl capacity and weight.
(blank)Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N).
10Port size 3/8". This body offers 10 = 3/8", 15 = 1/2".
(blank)Drain: Semi-auto drain + manual drain.
SStandard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L).
NNo pressure gauge; 1/4" gauge connection.
WFiltering grade 5 µm.
(blank)PT thread; gauge scale MPa / psi.
KReverse-flow (reflux) valve attached.

Constituent units, orderable separately as spares: GAFR400-10 filter & regulator, GAL400-10 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.

Size Class & Flow Envelope

  • GAFC2001/8"-1/4" · 1750 L/min
  • GAFC3001/4"-1/2" · 3500 L/min
  • GAFC4003/8"-1/2" · 6000 L/min
  • GAFC5003/4" · 7000 L/min
  • GAFC6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.

This modelGAFC400 · 3/8" · curve to 6000 L/min
One size downGAFC300
One size upGAFC500 (curve to 7000 L/min)
Build orderFilter & regulator → bracket → lubricator

Where the Airtac GAFC Air Service Unit GAFC40010SNWK Is Used

precision_manufacturing

Precision valve control

Feed a bank of solenoid valves on a pick-and-place machine where the 5 um element keeps fine particles away from spool surfaces and the regulated 0.9 MPa top holds consistent actuation.

factory

Assembly line tooling

Power pneumatic screwdrivers on a multi-station assembly line, where the 185 cc oil bowl keeps tool lubrication steady between shifts and the 100 cc drain bowl handles condensate from humid plant air.

engineering

Test bench air supply

Supply a laboratory test bench checking cylinder seals, where the 5 um element protects sensitive test fixtures and the semi-auto drain clears moisture without interrupting long test cycles.

Is the Airtac GAFC Air Service Unit GAFC40010SNWK the Right Air-Prep Unit?

Choose the GAFC40010SNWK when a 3/8" port and the 0.15-0.9 MPa (20-130 psi) standard range fit your circuit. The 5 um element traps finer particles than the standard 40 um, which helps precision valves but requires more frequent element service. The PC bowl is the default build; confirm it suits your environment since the catalogue gives no material-specific ratings. The semi-auto and manual drains are both fitted, and the reverse-flow (reflux) valve is included as an ordering difference. Spare parts are the GAFR400-10 filter-regulator and GAL400-10 lubricator, both orderable separately. Since no gauge is supplied, the 1/4" connection allows a field-installed gauge. The 1.0 MPa max supply leaves about 0.1 MPa above the 0.9 MPa top of the range, so plan your inlet pressure accordingly.

Quick checklist

  • ✓ Body size for your peak flow (3/8" here)
  • ✓ Standard 0.9 MPa or lower-pressure 0.4 MPa
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Element 40 µm or 5 µm
  • ✓ Thread & gauge scale (PT / G / NPT)
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter-regulator first, lubricator last.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Fill the oil bowl with ISO VG 32 or equivalent only.
  • check Drain condensate before the 100 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 1810 g unit on its bracket, not on the tubing.

The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR400-10 filter-regulator on that branch instead of the full combination.

Airtac GAFC Air Service Unit GAFC40010SNWK FAQ

The GAFC40010SNWK operates at 0.15-0.9 MPa (20-130 psi) with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). Temperature range is -5 to 70 C. It has a 100 cc drain bowl and 185 cc oil bowl, weighs 1810 g, and uses ISO VG 32 oil. The 5 um element filters the air before it reaches the regulator.

The N in the code means no gauge is supplied. The GAFC400 body has a 1/4" gauge connection, so you can add a field-installed gauge to read the set pressure. Without one, the regulated pressure cannot be read directly on the unit.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GAFC Air Service Unit GAFC40010SNWK

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for GAFC40010SNWK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.