The AirTAC Airtac GAFC Air Service Unit GAFC400C10ALW is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 3/8" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
This AirTAC F.R.L. combination pairs a filter-regulator with a lubricator on a single T-bracket, so the air is cleaned, set to pressure, and then oil-misted in one compact line. The GAFC400 body uses a 3/8" port and weighs 1810 g, placing it in the mid-range class where a panel or frame mount is expected rather than support from the tubing.
The lower-pressure regulator operates from 0.15 to 0.4 MPa (20-58 psi), which suits machines with a modest pressure ceiling. A 5 um element traps fine particles for sensitive valves, while the metal bowl and automatic drain handle condensate without an operator. The circular gauge reads in MPa and psi, and the 100 cc drain bowl plus 185 cc oil bowl define the service rhythm.
| Model | Airtac GAFC Air Service Unit GAFC400C10ALW |
|---|---|
| Series | GAFC400 F.R.L. combination |
| Port size | 3/8" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Metal |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1810 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.
| GAFC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAFR400-10 filter & regulator, GAL400-10 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC400 · 3/8" · curve to 6000 L/min |
|---|---|
| One size down | GAFC300 |
| One size up | GAFC500 (curve to 7000 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Feed a bank of fine pneumatic valves on a small assembly machine where the 5 um element protects sensitive internal clearances and the lower pressure range prevents over-pressuring delicate actuators.
Install on a packaging line with a wet air supply; the automatic drain clears the 100 cc bowl without an operator, while the metal bowl suits a floor-level position where impacts are possible.
Use on a bench test station that checks components at 0.3 MPa; the 0.15-0.4 MPa band gives fine adjustment and the gauge confirms the setpoint for each test run.
Choose the GAFC400C10ALW when your line needs 3/8" ports and a regulated band capped at 0.4 MPa. The metal bowl is specified by the C code, and the automatic drain clears water without manual attention, which suits wet or unattended air supplies. The 5 um element filters finer than the standard 40 um grade, but expect to service it more often. The PT thread carries a gauge scale in MPa and psi, so operators read the setpoint directly on the fitted circular gauge. For a higher pressure ceiling, step to the standard S type; for oil-free downstream air, omit the lubricator and select a GAFR400-10 filter-regulator instead. Spare parts are the GAFR400-10 and GAL400-10, both orderable separately. The 1.0 MPa max supply leaves about 0.6 MPa above the 0.4 MPa top of the range.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR400-10 filter-regulator on that branch instead of the full combination.
This F.R.L. combination operates from 0.15 to 0.4 MPa (20-58 psi) with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). The temperature range is -5 to 70 C, and the recommended lubricant is ISO VG 32. It has a 100 cc drain bowl and a 185 cc oil bowl, weighs 1810 g, and uses a 5 um filter element.
The C in the model code specifies a metal bowl, which is a build choice for the unit's surroundings. The catalogue gives the same 1.0 MPa max pressure and -5 to 70 C temperature range for all bowl materials, so confirm the metal bowl suits your environment. The automatic drain (A) clears condensate without manual intervention.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.