The AirTAC Airtac GAFC Air Service Unit GAFC400C10LN is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 3/8" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
This AirTAC GAFC400C10LN is a two-piece F.R.L. combination: a filter-regulator body paired with a lubricator, mounted on a shared T-bracket with quick clamps. Air is cleaned and set to pressure in the first body, then the lubricator adds a metered oil mist downstream, so oil never travels back through the regulator seat.
The 3/8in port and 1810 g mass place it in the mid-size class, suited for a machine header feeding several actuators. It works in the lower-pressure band of 0.15-0.4 MPa (20-58 psi) with a 40 um element, and the metal bowl holds 100 cc of condensate while the oil bowl holds 185 cc. No gauge is fitted, so the set pressure cannot be read without adding one to the 1/4in gauge connection.
| Model | Airtac GAFC Air Service Unit GAFC400C10LN |
|---|---|
| Series | GAFC400 F.R.L. combination |
| Port size | 3/8" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Metal |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1810 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFC400 is 1/4" if you add one.
| GAFC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/4" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAFR400-10 filter & regulator, GAL400-10 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC400 · 3/8" · curve to 6000 L/min |
|---|---|
| One size down | GAFC300 |
| One size up | GAFC500 (curve to 7000 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Set a lathe's air chuck to a stable 0.3 MPa (43 psi) with the lower-pressure regulator, protecting delicate workpieces from over-clamping while the lubricator keeps the chuck cylinder moving smoothly.
Feed a 3/8in line to a small conveyor's guide rails and sensors, using the 185 cc oil bowl to keep the mechanism misted for long shifts without frequent topping up.
Power a pneumatic test fixture that cycles at low pressure, relying on the 100 cc condensate bowl to collect moisture from a wet compressor line before it reaches the regulator seat.
Choose the GAFC400C10LN when your line needs a 3/8in port and a regulated ceiling of 0.4 MPa (20-58 psi). The metal bowl is a build choice for the environment, but the catalogue gives no impact or chemical data, so confirm it suits your surroundings. The semi-auto drain dumps condensate each time pressure drops, with a manual drain for on-demand use, and the 40 um element handles standard shop air. For finer filtration, the W option swaps to a 5 um element at the cost of more frequent service. The N code means no gauge is supplied; the 1/4in connection accepts one later, and the PT thread carries an MPa/psi scale if you add it. Spares are orderable as the GAFR400-10 filter & regulator and the GAL400-10 lubricator, so a damaged bowl does not force a whole new assembly. A 1.0 MPa max supply leaves about 0.6 MPa above the 0.4 MPa top of the range, so plan the inlet pressure with that margin in mind.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR400-10 filter-regulator on that branch instead of the full combination.
This F.R.L. combination operates from 0.15 to 0.4 MPa (20-58 psi) with a max pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It handles temperatures from -5 to 70 C and needs ISO VG 32 oil in the lubricator. The metal drain bowl holds 100 cc, the oil bowl holds 185 cc, and the complete unit weighs 1810 g with a 3/8in port.
The N in the code after the port means no gauge is supplied, which keeps the unit compact and reduces cost if you monitor pressure elsewhere. If you need to read the set pressure locally, the GAFC400 body has a 1/4in gauge connection where a standard gauge can be added later, reading in MPa and psi for the PT thread.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.