The AirTAC Airtac GAFC Air Service Unit GAFC400C10LNK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 3/8" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
This AirTAC GAFC400C10LNK is an F.R.L. combination that pairs a filter-regulator with a lubricator on a single T-shaped bracket. The filter and regulator share one body, so the set is two pieces instead of three, which means one less inter-unit joint to seal. Air enters the 3/8" port, gets filtered and regulated down to the 0.15-0.4 MPa (20-58 psi) range, then the lubricator adds a controlled oil mist last, downstream of the regulator seat.
The metal bowl holds 100 cc of condensate and the oil bowl holds 185 cc, so the service interval is driven by how much water your compressor pushes through. The 40 um element handles standard shop air, and the unit weighs 1810 g, which tells you it needs a proper panel or frame mount rather than support from the tubing. A reverse-flow valve is fitted, and the catalogue draws it as a separate pneumatic symbol.
| Model | Airtac GAFC Air Service Unit GAFC400C10LNK |
|---|---|
| Series | GAFC400 F.R.L. combination |
| Port size | 3/8" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Metal |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1810 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFC400 is 1/4" if you add one.
| GAFC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/4" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAFR400-10 filter & regulator, GAL400-10 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC400 · 3/8" · curve to 6000 L/min |
|---|---|
| One size down | GAFC300 |
| One size up | GAFC500 (curve to 7000 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Set a lathe chuck or a clamping fixture to a precise 0.3 MPa without worrying about the upper range, since the L type gives finer adjustment below 0.4 MPa.
Feed a spray gun at a stable low pressure, where the 40 um element keeps the line clean and the lubricator adds oil mist for the gun's moving parts.
Run a small pneumatic press or a parts feeder at a consistent low pressure, with the metal bowl handling occasional water slugs from a wet compressor line.
The L in this code means lower-pressure regulation, topping out at 0.4 MPa instead of the standard 0.9 MPa. If your machine might ever need more than 0.4 MPa, this is the wrong part, so check the duty cycle before ordering. The metal bowl is a build choice for the environment, but the specification does not change with it, so confirm it suits your surroundings. No gauge is supplied with this model, but the gauge connection is 1/4" if you add one later, and the PT thread means the scale would read MPa/psi. The semi-auto drain dumps condensate on each pressure drop, and the manual drain works on demand, so someone needs to attend the bowl periodically. The reverse-flow valve is fitted, and the two units are orderable separately as GAFR400-10 and GAL400-10. With a 1.0 MPa max supply, you have about 0.6 MPa of headroom above the 0.4 MPa top of the regulated range, so plan the inlet pressure accordingly.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR400-10 filter-regulator on that branch instead of the full combination.
The GAFC400C10LNK operates at 0.15-0.4 MPa (20-58 psi) with a max pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It works in temperatures from -5 to 70 C and uses ISO VG 32 oil. The drain bowl holds 100 cc and the oil bowl holds 185 cc, with a total weight of 1810 g.
The N in the code means no gauge is supplied, so you cannot read the set pressure directly on the unit. The gauge connection is 1/4" if you want to add one later, and the PT thread means the scale would be MPa/psi. For a lower-pressure application, adding a gauge helps the operator verify the 0.15-0.4 MPa setting.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.