The AirTAC Airtac GAFC Air Service Unit GAFC400C10LNW is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 3/8" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
This AirTAC GAFC400C10LNW is an F.R.L. combination built as two units on one bracket: the filter and regulator share a single body, with the lubricator mounted downstream. The 3/8in port size and 1810 g mass place it in the mid-range class, where the 100 cc condensate bowl and 185 cc oil bowl reduce how often the unit needs attention. It regulates from 0.15 to 0.4 MPa (20-58 psi), and the 5 um element traps finer particles for sensitive equipment.
The metal bowl is specified by the C code, and the shared specification of 1.0 MPa maximum pressure and -5 to 70 C operation applies regardless of bowl material. With the N code, no gauge is supplied; the 1/4in gauge connection on the GAFC400 body allows one to be added later. The semi-auto drain dumps condensate when pressure drops, while the manual drain offers on-demand release.
| Model | Airtac GAFC Air Service Unit GAFC400C10LNW |
|---|---|
| Series | GAFC400 F.R.L. combination |
| Port size | 3/8" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Metal |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1810 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFC400 is 1/4" if you add one.
| GAFC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/4" gauge connection. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAFR400-10 filter & regulator, GAL400-10 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC400 · 3/8" · curve to 6000 L/min |
|---|---|
| One size down | GAFC300 |
| One size up | GAFC500 (curve to 7000 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Feed a 3/8in line to a CNC tool changer or a precision grinding spindle, where the 5 um element protects sensitive valves and the lower pressure range prevents over-pressurizing delicate actuators.
Use on a carton erector or a label applicator that runs on regulated air below 0.4 MPa, where the 185 cc oil bowl keeps the lubricator running longer between refills.
Mount on a multi-station assembly bench with 3/8in drops, where the 100 cc condensate bowl and semi-auto drain handle moisture from a humid plant air supply.
Choose the GAFC400C10LNW when your line needs 3/8in ports and a lower regulated ceiling of 0.4 MPa. The metal bowl is a build choice; confirm it suits your environment, as the catalogue provides no material-specific ratings. The 5 um element suits precision valves or instrument air, but expect more frequent element service than a 40 um unit. The semi-auto and manual drains are both fitted, and the PT thread carries a gauge scale of MPa/psi if you add a gauge later. For oil-free air downstream, omit the lubricator and select a plain GAFR400-10 filter-regulator instead. Spare parts are orderable as GAFR400-10 and GAL400-10. With a 1.0 MPa max supply, you have about 0.6 MPa of headroom above the 0.4 MPa top of this unit's range.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR400-10 filter-regulator on that branch instead of the full combination.
It operates from 0.15 to 0.4 MPa (20-58 psi), with a maximum pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). The temperature range is -5 to 70 C, and it uses ISO VG 32 lubricant. The drain bowl holds 100 cc, the oil bowl holds 185 cc, and the unit weighs 1810 g.
The N after the port code means no gauge is supplied with this unit. The GAFC400 body has a 1/4in gauge connection, so you can add a circular gauge later if you need to read the set pressure. The PT thread on this model uses an MPa/psi scale for any gauge you install.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.