verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GAFC400 · F.R.L. Combination (Filter-Regulator + Lubricator)

Airtac GAFC Air Service Unit GAFC400C10LNWK

The AirTAC Airtac GAFC Air Service Unit GAFC400C10LNWK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 3/8" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).

  • TypeF.R.L. combination
  • Port size3/8"
  • Pressure range0.15 - 0.4 MPa (20 - 58 psi)
  • Filtering grade5 µm
  • Bowl materialMetal
  • Drainsemi-auto + manual
  • Pressure gaugeNot fitted
  • Weight1810 g
$113.61 $124.97Save 9% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GAFC Air Service Unit GAFC400C10LNWK

This GAFC400C10LNWK is a two-piece F.R.L. combination: a filter-regulator body paired with a lubricator, mounted on a T-bracket with quick clamps. It handles a 3/8in port and weighs 1810 g, placing it in the mid-size class for multi-actuator circuits. The lower-pressure type regulates from 0.15 to 0.4 MPa (20-58 psi), with a 5 um element for finer filtration.

The metal bowl holds 100 cc for condensate and 185 cc for oil, so service intervals are generous for a unit this size. No gauge is supplied, but the 1/4in gauge connection allows one to be added. A reverse-flow valve is fitted, and the lubricator adds oil mist after the air is filtered and set to pressure.

Airtac GAFC Air Service Unit GAFC400C10LNWK Technical Specifications

ModelAirtac GAFC Air Service Unit GAFC400C10LNWK
SeriesGAFC400 F.R.L. combination
Port size3/8" (PT thread)
Filtering grade5 µm
Pressure range0.15 - 0.4 MPa (20 - 58 psi)
TypeLower pressure
Bowl materialMetal
Drain typeSemi-auto drain + manual drain
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl100 cc
Capacity of oil bowl185 cc
Recommended lubricantISO VG 32 or equivalent
Weight1810 g

Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFC400 is 1/4" if you add one.

Model Code: Airtac GAFC Air Service Unit GAFC400C10LNWK

GAFC400GA400 series F.R.L. unit — sets ports, bowl capacity and weight.
CBowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N).
10Port size 3/8". This body offers 10 = 3/8", 15 = 1/2".
(blank)Drain: Semi-auto drain + manual drain.
LLower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L).
NNo pressure gauge; 1/4" gauge connection.
WFiltering grade 5 µm.
(blank)PT thread; gauge scale MPa / psi.
KReverse-flow (reflux) valve attached.

Constituent units, orderable separately as spares: GAFR400-10 filter & regulator, GAL400-10 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.

Size Class & Flow Envelope

  • GAFC2001/8"-1/4" · 1750 L/min
  • GAFC3001/4"-1/2" · 3500 L/min
  • GAFC4003/8"-1/2" · 6000 L/min
  • GAFC5003/4" · 7000 L/min
  • GAFC6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.

This modelGAFC400 · 3/8" · curve to 6000 L/min
One size downGAFC300
One size upGAFC500 (curve to 7000 L/min)
Build orderFilter & regulator → bracket → lubricator

Where the Airtac GAFC Air Service Unit GAFC400C10LNWK Is Used

precision_manufacturing

Precision valve islands

Feed a bank of solenoid valves on a pick-and-place machine where 5 um filtration protects tight spool clearances and the 0.4 MPa ceiling suits low-force grippers.

factory

Assembly line workstations

Supply a multi-station assembly bench with regulated air for screwdrivers and presses, where the 185 cc oil bowl keeps lubricators topped up across shifts.

engineering

Test rigs and lab equipment

Run a pneumatic test fixture that needs clean, oil-misted air at a stable low pressure, with the metal bowl standing up to frequent handling.

Is the Airtac GAFC Air Service Unit GAFC400C10LNWK the Right Air-Prep Unit?

Choose this GAFC400C10LNWK when your line needs finer 5 um filtration and a lower pressure ceiling of 0.4 MPa. The metal bowl is a build choice; the catalogue lists no performance difference versus PC or nylon, so confirm it suits your environment. The semi-auto drain dumps condensate when pressure drops, while the manual drain works on demand. No gauge is included, so plan to read pressure elsewhere or add one to the 1/4in connection. The reverse-flow valve is fitted per the K code. Spares are the GAFR400-10 filter-regulator and GAL400-10 lubricator, both orderable separately. The 1.0 MPa max supply leaves about 0.6 MPa above the 0.4 MPa top of the range.

Quick checklist

  • ✓ Body size for your peak flow (3/8" here)
  • ✓ Standard 0.9 MPa or lower-pressure 0.4 MPa
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Element 40 µm or 5 µm
  • ✓ Thread & gauge scale (PT / G / NPT)
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter-regulator first, lubricator last.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Fill the oil bowl with ISO VG 32 or equivalent only.
  • check Drain condensate before the 100 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 1810 g unit on its bracket, not on the tubing.

The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR400-10 filter-regulator on that branch instead of the full combination.

Airtac GAFC Air Service Unit GAFC400C10LNWK FAQ

It operates from 0.15 to 0.4 MPa (20-58 psi) with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). Temperature range is -5 to 70 C. It has a 100 cc drain bowl and 185 cc oil bowl, weighs 1810 g, and uses ISO VG 32 lubricant. The element is 5 um.

The N in the code means no gauge is supplied. The GAFC400 body has a 1/4in gauge connection, so you can add a circular gauge later if you need to read the set pressure directly. The thread is PT with a MPa/psi scale if you fit one.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GAFC Air Service Unit GAFC400C10LNWK

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for GAFC400C10LNWK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.