The AirTAC Airtac GAFC Air Service Unit GAFC400N10ALN is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 3/8" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
This GAFC400N10ALN is a two-piece F.R.L. combination: a filter-regulator body paired with a lubricator on a shared T-bracket. The 3/8in port and 1810 g mass put it in the mid-size class, suited to a machine header feeding several actuators rather than a single small cylinder.
The lower-pressure regulator is set for 0.15-0.4 MPa (20-58 psi), with a 40 um element and an automatic drain. The nylon bowl holds 100 cc of condensate and the oil bowl 185 cc. No gauge is fitted, so the 1/4in gauge connection is available if you add one. The lubricator adds oil mist after regulation, so the line is not oil-free as supplied.
| Model | Airtac GAFC Air Service Unit GAFC400N10ALN |
|---|---|
| Series | GAFC400 F.R.L. combination |
| Port size | 3/8" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Nylon |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1810 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFC400 is 1/4" if you add one.
| GAFC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/4" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAFR400-10 filter & regulator, GAL400-10 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC400 · 3/8" · curve to 6000 L/min |
|---|---|
| One size down | GAFC300 |
| One size up | GAFC500 (curve to 7000 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Set a stable 0.3 MPa supply for a small indexing table or a light press, where the lower-pressure range gives finer adjustment than a standard 0.9 MPa regulator.
Feed a multi-spindle drilling station where the automatic drain clears water from the 100 cc bowl, reducing manual checks on a line with high humidity.
Supply oil-misted air to a pair of guided cylinders on a packaging machine, with the 185 cc oil bowl supporting longer runs between refills.
Choose the GAFC400N10ALN when your circuit needs a regulated 0.15-0.4 MPa (20-58 psi) band and you want the automatic drain to handle condensate without operator attention. The nylon bowl is a build choice; the catalogue gives no impact or chemical data, so confirm it suits your surroundings. The 40 um element handles general shop air, and the PT thread with MPa/psi gauge scale matches common local fittings. The two units are orderable separately as GAFR400-10 and GAL400-10. With a 1.0 MPa max supply, you have about 0.6 MPa above the 0.4 MPa top of the range, so plan the inlet pressure accordingly.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR400-10 filter-regulator on that branch instead of the full combination.
The pressure range is 0.15-0.4 MPa (20-58 psi), max pressure 1.0 MPa (145 psi), proof pressure 1.5 MPa (215 psi). Temperature range is -5 to 70 C. The drain bowl holds 100 cc and the oil bowl 185 cc. Recommended lubricant is ISO VG 32. The unit weighs 1810 g and has a 3/8in port.
The N after the port code means no gauge is supplied. The GAFC400 body has a 1/4in gauge connection, so you can add a pressure gauge later if you need to read the setpoint. Without one, the regulated pressure cannot be verified visually.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.