The AirTAC Airtac GAFC Air Service Unit GAFC400N10ALNK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 3/8" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
This GAFC400N10ALNK is a two-piece F.R.L. combination: a GA-series filter-regulator (the filter and regulator share one body) paired with a GA-series lubricator on a T-shape bracket with quick clamps. The 3/8in port and 1810 g mass put it in the mid-size class, a step up from the GAFC300's 1020 g for lines that need more condensate and oil capacity.
The lower-pressure type regulates from 0.15 to 0.4 MPa (20-58 psi), with a 1.0 MPa (145 psi) maximum supply and 1.5 MPa (215 psi) proof pressure. The 40 um element handles standard shop air, the automatic drain clears the 100 cc condensate bowl without an operator, and the 185 cc oil bowl feeds ISO VG 32 lubricant. No gauge is fitted; the 1/4in gauge connection is ready for one if you add it later.
| Model | Airtac GAFC Air Service Unit GAFC400N10ALNK |
|---|---|
| Series | GAFC400 F.R.L. combination |
| Port size | 3/8" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Nylon |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1810 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFC400 is 1/4" if you add one.
| GAFC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/4" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAFR400-10 filter & regulator, GAL400-10 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC400 · 3/8" · curve to 6000 L/min |
|---|---|
| One size down | GAFC300 |
| One size up | GAFC500 (curve to 7000 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Feed a bank of small pneumatic valves on a packaging line where the lower 0.4 MPa ceiling protects delicate actuators from over-pressure.
Supply filtered, regulated air to coolant valves on a CNC lathe, with the automatic drain handling condensate from a humid shop floor.
Prepare air for a bench-top press or torque tool on an assembly line, where the 185 cc oil bowl keeps the lubricator running between shifts.
The GAFC400 body offers 3/8in and 1/2in ports; this 3/8in version suits feeds to a single machine station or a small header. The L type tops out at 0.4 MPa, so if your process may ever need more than that, step up to the S type (0.15-0.9 MPa) instead. The nylon bowl is a build choice - the common specification (1.0 MPa max, -5 to 70 C) is identical across PC, metal and nylon, so confirm it suits your surroundings. The automatic drain is the right pick for unattended or wet lines, while the 40 um element is the standard grade. The reverse-flow (reflux) valve is fitted, and the PT thread carries a gauge scale in MPa/psi if you add the optional gauge. Spares are orderable as GAFR400-10 and GAL400-10. The 1.0 MPa max supply leaves about 0.6 MPa above the 0.4 MPa top of the range, so plan your inlet pressure with that margin in mind.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR400-10 filter-regulator on that branch instead of the full combination.
This F.R.L. combination operates at 0.15-0.4 MPa (20-58 psi) with a maximum supply of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). The temperature range is -5 to 70 C, and it uses ISO VG 32 lubricant. The drain bowl holds 100 cc and the oil bowl 185 cc, with a total weight of 1810 g. The 40 um element filters the air, and the automatic drain clears condensate without manual attention.
The N after the port code means no gauge is supplied. The GAFC400 body has a 1/4in gauge connection, so you can add a circular gauge later if you need to read the set pressure. The PT thread would use a gauge with an MPa/psi scale.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.