The AirTAC Airtac GAFC Air Service Unit GAFC400N10ASK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 3/8" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
This AirTAC GAFC400N10ASK is a two-piece F.R.L. combination: the filter and regulator share one body, and a lubricator is mounted on the same T-bracket. Air is cleaned and set to pressure in the first unit, then the lubricator adds a metered oil mist last, so oil never travels back through the regulator seat. With a 3/8" port and 1810 g mass, it suits mid-size machine headers where a panel or frame mount is expected rather than tubing support.
The standard pressure range is 0.15-0.9 MPa (20-130 psi), with a 40 um element and an automatic drain. The nylon bowl holds 100 cc of condensate, while the separate oil bowl holds 185 cc, and the circular gauge reads in MPa/psi for the default PT thread. A reverse-flow (reflux) valve is fitted, and the catalogue flow curve for this body is plotted to 6000 L/min at 0.7 MPa inlet as a sizing envelope.
| Model | Airtac GAFC Air Service Unit GAFC400N10ASK |
|---|---|
| Series | GAFC400 F.R.L. combination |
| Port size | 3/8" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Nylon |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1810 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.
| GAFC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAFR400-10 filter & regulator, GAL400-10 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC400 · 3/8" · curve to 6000 L/min |
|---|---|
| One size down | GAFC300 |
| One size up | GAFC500 (curve to 7000 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Feed a 3/8" line to a CNC spindle air system where the regulator holds 0.5 MPa and the lubricator meters oil to way lube points. The 185 cc oil bowl supports longer runs between refills.
Mount on a panel above a multi-station assembly bench, supplying filtered and regulated air to pneumatic screwdrivers and pick-and-place grippers. The automatic drain keeps the 100 cc bowl clear during shifts.
Use on a packaging line's main header to condition air for cylinders and valves. The 3/8" port and 6000 L/min envelope at 0.7 MPa inlet support several actuators, while the reflux valve is fitted for reverse-flow conditions.
Choose the GAFC400N10ASK when you need a 3/8" port with a 100 cc condensate bowl and 185 cc oil bowl, giving fewer service stops than the GAFC300's 60 cc and 98 cc bowls. The nylon bowl is specified by the N before the port, and the automatic drain (A) clears condensate without an operator, which suits wet or unattended lines. The standard type (S) regulates from 0.15 to 0.9 MPa, and the fitted gauge reads in MPa/psi on the PT thread; the 40 um element is the default, and the K code adds the reverse-flow valve. Replacement units are orderable separately as the GAFR400-10 filter & regulator and the GAL400-10 lubricator, so a clogged element or damaged bowl does not mean replacing the whole assembly. Since the lubricator adds oil mist, choose a plain GAFR filter-regulator if the line must stay oil-free. Max supply is 1.0 MPa, which leaves about 0.1 MPa above the 0.9 MPa top of the regulated range, so plan a supply near 1.0 MPa if you need 0.9 MPa out.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR400-10 filter-regulator on that branch instead of the full combination.
The GAFC400N10ASK operates from 0.15 to 0.9 MPa (20-130 psi), with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). Temperature range is -5 to 70 C, and the recommended lubricant is ISO VG 32. The condensate bowl holds 100 cc and the oil bowl holds 185 cc, with a total weight of 1810 g. The 40 um element filters the air, and the automatic drain clears condensate without operator intervention.
The K code indicates the reverse-flow (reflux) valve is fitted to this GAFC400N10ASK. The catalogue shows it as a separate pneumatic symbol in the circuit. This is an ordering difference from models without the K code, which do not have the valve attached.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.