The AirTAC Airtac GAFC Air Service Unit GAFC400N10L is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 3/8" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
This AirTAC GAFC400N10L is a two-piece F.R.L. combination: the first body houses the filter and regulator together, and the second body is the lubricator. They mount on a shared T-bracket with quick clamps, so the 3/8in port unit weighs 1810 g and needs a proper panel or frame mount, not support from the tubing.
The lower-pressure regulator is set for 0.15-0.4 MPa (20-58 psi), and the 40 um element cleans the air before the lubricator adds a metered oil mist last. The nylon bowl is named as a build choice, but the catalogue gives no impact or chemical data for it, so confirm it suits your surroundings. The circular gauge is fitted and reads in MPa and psi.
| Model | Airtac GAFC Air Service Unit GAFC400N10L |
|---|---|
| Series | GAFC400 F.R.L. combination |
| Port size | 3/8" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Nylon |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1810 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.
| GAFC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAFR400-10 filter & regulator, GAL400-10 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC400 · 3/8" · curve to 6000 L/min |
|---|---|
| One size down | GAFC300 |
| One size up | GAFC500 (curve to 7000 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Set a precise 0.3 MPa for a delicate pneumatic clamp on a CNC fixture, where the lower-pressure range gives finer adjustment than a standard regulator.
Feed a small assembly station's pneumatic screwdriver with filtered, regulated air and a consistent oil mist, keeping the tool running smoothly.
Supply a laboratory test jig that requires a stable, low-pressure air source, with the 40 um element protecting sensitive test valves from particulates.
Choose the GAFC400 for a 3/8in port line that needs a 100 cc condensate bowl and a 185 cc oil bowl, giving a longer service interval than the GAFC300's 60 cc and 98 cc bowls. The L type tops out at 0.4 MPa, so if your machine may ever need more than that, pick the standard S type instead. The nylon bowl is a material choice, not a performance upgrade, and the semi-auto drain dumps on each pressure drop while the manual drain works on demand. The 40 um element is the standard grade, and the PT thread means the gauge scale is MPa/psi. The two units are orderable separately as the GAFR400-10 filter & regulator and the GAL400-10 lubricator. With a 1.0 MPa max supply, you have about 0.6 MPa above the 0.4 MPa top of the range, so plan your inlet pressure accordingly.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR400-10 filter-regulator on that branch instead of the full combination.
The GAFC400N10L operates at 0.15-0.4 MPa (20-58 psi), with a max pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It has a 100 cc drain bowl and a 185 cc oil bowl, weighs 1810 g, and is rated for -5 to 70 C. The recommended lubricant is ISO VG 32.
The 'L' designates the lower-pressure type, which regulates from 0.15 to 0.4 MPa (20-58 psi). This is different from the standard 'S' type that goes up to 0.9 MPa. If your application might need more than 0.4 MPa, the 'L' type is not suitable.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.