The AirTAC Airtac GAFC Air Service Unit GAFC400N10LK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 3/8" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).

  • TypeF.R.L. combination
  • Port size3/8"
  • Pressure range0.15 - 0.4 MPa (20 - 58 psi)
  • Filtering grade40 µm
  • Bowl materialNylon
  • Drainsemi-auto + manual
  • Pressure gaugeCircular, MPa / psi
  • Weight1810 g
$119.04 $130.76Save 8% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GAFC Air Service Unit GAFC400N10LK

This GAFC400N10LK is a two-piece F.R.L. combination: a filter-regulator body paired with a lubricator on a shared T-bracket. The 3/8in port and 1810 g mass place it in the mid-range class, sized for a machine header feeding several actuators. It regulates from 0.15 to 0.4 MPa (20-58 psi), with the 40 um element filtering supply air before the lubricator meters oil mist downstream.

The nylon bowl holds 100 cc of condensate, while the separate 185 cc oil bowl extends time between refills. The circular gauge reads MPa/psi, and the semi-auto drain dumps condensate on pressure drops with a manual backup. A reverse-flow valve is fitted, and the catalogue shows it as a separate pneumatic symbol.

Airtac GAFC Air Service Unit GAFC400N10LK Technical Specifications

ModelAirtac GAFC Air Service Unit GAFC400N10LK
SeriesGAFC400 F.R.L. combination
Port size3/8" (PT thread)
Filtering grade40 µm
Pressure range0.15 - 0.4 MPa (20 - 58 psi)
TypeLower pressure
Bowl materialNylon
Drain typeSemi-auto drain + manual drain
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl100 cc
Capacity of oil bowl185 cc
Recommended lubricantISO VG 32 or equivalent
Weight1810 g

Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.

Model Code: Airtac GAFC Air Service Unit GAFC400N10LK

GAFC400GA400 series F.R.L. unit — sets ports, bowl capacity and weight.
NBowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N).
10Port size 3/8". This body offers 10 = 3/8", 15 = 1/2".
(blank)Drain: Semi-auto drain + manual drain.
LLower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L).
(blank)Circular pressure gauge fitted.
(blank)Filtering grade 40 µm.
(blank)PT thread; gauge scale MPa / psi.
KReverse-flow (reflux) valve attached.

Constituent units, orderable separately as spares: GAFR400-10 filter & regulator, GAL400-10 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.

Size Class & Flow Envelope

  • GAFC2001/8"-1/4" · 1750 L/min
  • GAFC3001/4"-1/2" · 3500 L/min
  • GAFC4003/8"-1/2" · 6000 L/min
  • GAFC5003/4" · 7000 L/min
  • GAFC6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.

This modelGAFC400 · 3/8" · curve to 6000 L/min
One size downGAFC300
One size upGAFC500 (curve to 7000 L/min)
Build orderFilter & regulator → bracket → lubricator

Where the Airtac GAFC Air Service Unit GAFC400N10LK Is Used

precision_manufacturing

Precision pressure setting

Set a lathe's air chuck to exactly 0.3 MPa (43 psi) using the circular gauge, with the lower-pressure range giving finer adjustment than a standard 0.9 MPa regulator.

factory

Machine header supply

Feed a 3/8in header on a small assembly station, where the 185 cc oil bowl keeps three pneumatic screwdrivers lubricated across a full shift.

engineering

Bench test rig

Supply a test fixture that cycles a cylinder at 0.35 MPa (51 psi), relying on the semi-auto drain to clear condensate from the 100 cc bowl between test runs.

Is the Airtac GAFC Air Service Unit GAFC400N10LK the Right Air-Prep Unit?

Choose this GAFC400N10LK when your line needs lower regulated pressure up to 0.4 MPa (20-58 psi) and the 3/8in port matches your manifold. The nylon bowl is a material choice, not a performance upgrade - the 1.0 MPa max and -5 to 70 C range are identical across bowl options, so confirm nylon suits your environment. The semi-auto drain handles condensate automatically on each pressure drop, with a manual drain for scheduled service. The 40 um element is the standard grade; step to the 5 um W option if you feed precision valves. The PT thread carries a gauge reading MPa/psi, and the K suffix adds the reverse-flow valve. Spares are GAFR400-10 and GAL400-10, both orderable separately. With a 1.0 MPa max supply, you have about 0.6 MPa above the 0.4 MPa top of the regulated band, so set the supply near 1.0 MPa if you need the full range.

Quick checklist

  • ✓ Body size for your peak flow (3/8" here)
  • ✓ Standard 0.9 MPa or lower-pressure 0.4 MPa
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Element 40 µm or 5 µm
  • ✓ Thread & gauge scale (PT / G / NPT)
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter-regulator first, lubricator last.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Fill the oil bowl with ISO VG 32 or equivalent only.
  • check Drain condensate before the 100 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 1810 g unit on its bracket, not on the tubing.

The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR400-10 filter-regulator on that branch instead of the full combination.

Airtac GAFC Air Service Unit GAFC400N10LK FAQ

This lower-pressure unit regulates from 0.15 to 0.4 MPa (20-58 psi), with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). It operates from -5 to 70 C, uses ISO VG 32 lubricant, and weighs 1810 g. The drain bowl holds 100 cc and the oil bowl 185 cc, with a 40 um element and a fitted gauge reading MPa/psi.

The K suffix specifies the reverse-flow (reflux) valve, which the AirTAC catalogue draws as a separate pneumatic symbol. It is fitted as an ordering option on this GAFC400N10LK; the catalogue defers functional details to its own page, so confirm the valve's role for your circuit from the datasheet.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GAFC Air Service Unit GAFC400N10LK

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for GAFC400N10LK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.