The AirTAC Airtac GAFC Air Service Unit GAFC400N10LNK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 3/8" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
This GAFC400N10LNK is a two-piece F.R.L. combination: a filter-regulator body handles filtration and pressure control, then a separate lubricator body adds a metered oil mist downstream. The 3/8in port and 1810 g mass place it in the mid-size class, suited for a machine header or a small multi-station line rather than a single actuator.
The lower-pressure regulator is set for 0.15-0.4 MPa (20-58 psi), with a 40 um element and a nylon bowl. The 100 cc condensate bowl and 185 cc oil bowl set the service rhythm, and since no gauge is fitted, the 1/4in gauge connection is left for a later add-on. The reverse-flow valve is included as an ordering option.
| Model | Airtac GAFC Air Service Unit GAFC400N10LNK |
|---|---|
| Series | GAFC400 F.R.L. combination |
| Port size | 3/8" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Nylon |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1810 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFC400 is 1/4" if you add one.
| GAFC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/4" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAFR400-10 filter & regulator, GAL400-10 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC400 · 3/8" · curve to 6000 L/min |
|---|---|
| One size down | GAFC300 |
| One size up | GAFC500 (curve to 7000 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Feed a multi-point clamping fixture on a CNC machine where the lower pressure range protects delicate workpieces from over-clamping, and the 100 cc bowl handles condensate from a busy shift.
Supply a metered oil mist to a bank of pneumatic screwdrivers on an assembly line, where the 185 cc oil bowl extends time between refills and the semi-auto drain clears water on each pressure drop.
Power a pneumatic test bench for valve actuation cycles, where the 0.15-0.4 MPa range suits low-force testing and the 6000 L/min envelope at 0.7 MPa inlet supports multiple test stations.
Choose the GAFC400 body when a 3/8in port with a 6000 L/min plotted flow envelope at 0.7 MPa inlet fits the line, and the 1810 g weight suits a panel or frame mount. The nylon bowl is a build choice; confirm it suits the environment, as the common specification of 1.0 MPa max and -5 to 70 C applies across materials. The semi-auto drain dumps on pressure drop, with a manual backup, and the 40 um element is the standard grade. The L type tops out at 0.4 MPa, so if the machine may need more pressure, this is the wrong part. No gauge is supplied, so plan to read pressure via the 1/4in connection. The PT thread carries a MPa/psi scale if a gauge is added. Spares are orderable as GAFR400-10 and GAL400-10. Max supply of 1.0 MPa leaves about 0.6 MPa above the 0.4 MPa top of the range, so plan the inlet pressure accordingly.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR400-10 filter-regulator on that branch instead of the full combination.
This F.R.L. combination operates at 0.15-0.4 MPa (20-58 psi) with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). Temperature range is -5 to 70 C, and the recommended lubricant is ISO VG 32. It has a 100 cc drain bowl, 185 cc oil bowl, and weighs 1810 g. The 40 um element filters the air, and the semi-auto drain clears condensate automatically on pressure drop.
The N after the port code means no gauge is supplied with this unit. The gauge connection on the GAFC400 body is 1/4in, so you can add a circular gauge later if needed. The PT thread on the connection uses an MPa/psi scale, which you should match to what your operators read.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.